³Ý±â¾î GS728TS, 24Æ÷Æ® 10/100/1000Base-T + 4Æ÷Æ® SFP, 2,5G Stack SFP Áö¿ø

´Ý±â

¼ºÀåÇÏ´Â ±â¾÷À» À§ÇØ ³×Æ®¿öÅ© È®Àå ¹× ÄÁ¹öÀü½º Çâ»óÀ» À§ÇÑ Â÷¼¼´ë ½ºÅÃÇü ±â°¡ºñÆ® ½º¸¶Æ® ½ºÀ§Ä¡


ProSafe¢ç Gigabit Stackable Smart Switch ÆÐ¹Ð¸®´Â ¼ºÀåÇÏ´Â Áß¼Ò±Ô¸ð ºñÁî´Ï½º¿¡¼­ ÇÊ¿äÇÑ È¿À²ÀûÀÎ ºñ¿ë°ú ¼Õ½¬¿î °ü¸® ±â´ÉÀ» °®Ã߸鼭 È®Àå °¡´É¼º°ú ¾ÈÁ¤¼º, °í¼º´ÉÀ» Á¦°øÇÕ´Ï´Ù.  NETGEARÀÇ 2¼¼´ë Stackable Smart SwitchµéÀº PoE Áö¿ø ȤÀº ¹ÌÁö¿ø ±â´ÉÀÇ 28/52 Æ÷Æ® ³»ÀåÀÇ ÃÑ 4°¡ÁöÀÇ ¸ðµ¨·Î ±¸¼ºµÇ¾î ÀÖ½À´Ï´Ù. ÀÌ ½ºÀ§Ä¡µéÀº ³ôÀº Æ÷Æ® ¹ÐÁýµµ¸¦ ÀÚ¶ûÇÏ¸ç ±¤Á¢¼ÓÀ» À§ÇØ ÅäÅ» 6°³ÀÇ SFP Æ÷Æ®¸¦ ³»ÀåÇϰí ÀÖ½À´Ï´Ù. ÀÌ Æ÷Æ®µé Áß 2°³´Â ÄÞº¸ ŸÀÔÀÌ¸ç ³ª¸ÓÁö 4°³´Â ½ºÅÂÅ· ȤÀº ¾÷¸µÅ©¸¦ À§ÇÑ Àü¿ë Æ÷Æ®µéÀÔ´Ï´Ù. ÀÌ Â÷¼¼´ë Stackable Smart SwitchµéÀº ¼ºÀåÇÏ´Â ºñÁî´Ï½º¿¡¼­ º¸´Ù Æí¸®ÇÏ°í ¾Æ¹« Àå¾Ö ¾øÀÌ ³×Æ®¿öÅ© È®ÀåÀÌ °¡´ÉÇϵµ·Ï ³ôÀº À¯¿¬¼º°ú È®À强À» ¾à¼ÓÇÕ´Ï´Ù. 

 

³ôÀº Ȱ¿ëµµ ¹× È®À强À» À§ÇÑ ½ºÅÂÅ· ±â´É

Â÷¼¼´ë Stackable Smart SwitchµéÀº ½ºÅÂÅ· ȤÀº ¾÷¸µÅ©¸¦ À§ÇØ Àü¸é¿¡ 2°³ÀÇ Àü¿ë Dual-purpose Æ÷Æ®µéÀ» »ç¿ëÇÕ´Ï´Ù. ÀÌ ½ºÅÂÅ· ±â´ÉÀº ³»ºÎ ½ºÅà Ʈ·¡ÇÈÀ» ¿î¹ÝÇϸ鼭 ³ôÀº ¼öÁØÀÇ Resilience¸¦ º¸ÀåÇÒ ¼ö ÀÖµµ·Ï 10Gbps µà¾ó ¸µ¿¡ ³ôÀº ¸®´ø´øÆ® ½ºÅÂÅ· ¹ö½º¸¦ Á¦°øÇÕ´Ï´Ù. ¶ÇÇÑ ÃÖ´ë 6´ëÀÇ ½ºÀ§Ä¡µéÀ» ½ºÅÃÇϰųª ÃÖ´ë 300°³ÀÇ 10/100/1000Mbps Æ÷Æ®µéÀ» Á¦°øÇÏ¿© ÇϳªÀÇ IP ÁÖ¼Ò¸¦ ÅëÇØ ¼Õ½¬¿î °ü¸®°¡ °¡´ÉÇÑ °¡»ó »þ½Ã¸¦ ±¸¼ºÇÒ ¼ö ÀÖ½À´Ï´Ù. ÀÌ ½ºÅÂÅ· ±â¼úÀº ¶ÇÇÑ ºñÁî´Ï½º ¿¬¼Ó¼ºÀ» º¸ÀåÇϰíÀÚ ¿©·¯ °³ÀÇ ³ôÀº Ȱ¿ë ±â´ÉÀ» Á¦°øÇÕ´Ï´Ù.:

  • Resiliency: Redundant ½ºÅÂÅ· Æ÷Æ® Á¢¼Ó ¶§¹®¿¡ ½ºÅÃ»ó¿¡ ÀÖ´Â ¾î¶°ÇÑ ½ºÀ§Ä¡¿¡ Àå¾Ö ¹ß»ý ½Ã ½Å¼ÓÇÑ Àç¼³Á¤ ±â´ÉÀ» ÅëÇØ ÀÚµ¿ Fail-over ±â´ÉÀ» Áö¿øÇÏ¿© ³×Æ®¿öÅ© DowntimeÀ» ¿¹¹æ.
  • Hot-swappable: ½ºÅÃ»ó¿¡ ÀÖ´Â ¸ðµç ½ºÀ§Ä¡µéÀº Hot-swap ±â´ÉÀÌ °¡´ÉÇÏ¿© ´Ù¸¥ ³×Æ®¿öÅ©¿¡ ¹æÇظ¦ ÁÖÁö ¾Ê°í ÅëÇÕ È¤Àº Á¦°Å°¡ °¡´ÉÇÕ´Ï´Ù.

 

±¤¹üÀ§ÇÑ °í±Þ °ü¸® ±â´É

ÀÌ Stackable Smart SwitchµéÀº º¸´Ù öÀúÇÑ º¸¾È ¹× ³ôÀº ¼­ºñ½º ¼öÁØ ¹× ³ôÀº Ȱ¿ëµµ¸¦ À§ÇØ ´Ù¾çÇÑ °í±Þ °ü¸® ±â´ÉÀ» Áö¿øÇϰí ÀÖ½À´Ï´Ù. ÀÌ ½ºÀ§Ä¡µéÀº Access Control Lists(ACL), static routing, rate limiting, IGMP snooping, ¹× Dynamic VLAN ÇÒ´ç  ±â´É µîÀ» žÀçÇÏ¿© Áß¼Ò±Ô¸ð ºñÁî´Ï½º¿¡ ¼ºÀåÇϴ ȤÀº »õ·Ó°Ô Ãß°¡ÇÏ´Â ³×Æ®¿öÅ©¿¡ ¾È¼º¸ÂÃãÀÔ´Ï´Ù.  ¶ÇÇÑ À½¼º ¹× ¿µ»óÀ» ¸ðµÎ Áö¿øÇÏ´Â ÄÁ¹öÀü½º ³×Æ®¿öÅ© ȯ°æ¿¡ ÀûÇÕÇÑ Stackable Smart SwitchµéÀº IP Æù ¹× IP Ä«¸Þ¶ó¸¦ À§ÇÑ QoS, º¸¾È, VLAN ¼¼ÆÃÀ» ÀÚµ¿À¸·Î ¼³Á¤ÇØ ÁÖ´Â Auto voice ¹× Auto video ±â´ÉÀ» ³»ÀåÇϰí ÀÖ½À´Ï´Ù.

 

IPv6 Áö¿ø

ÀÎÅÍ³Ý ¼­ºñ½º Á¦°ø¾÷ÀÚµéÀÇ IPv6 ÁÖ¼Ò·ÎÀÇ Àüȯ¿¡ ºÎÇÕÇϰíÀÚ ÀÌ 2¼¼´ë Stackable Gigabit Smart SwitchµéÀº IPv6 Áö¿øÀ» QoS, ACL ¹× multicast¿¡ ±îÁö È®Àå Àû¿ëÇÏ¿© ±Í»çÀÇ ³×Æ®¿öÅ©´Â IPv6ÀÇ ÇýÅÃÀ» ´©¸± ¼ö ÀÖÀ¸¸ç ÇâÈÄ ¾÷±×·¹À̵尡 ÇÊ¿ä¾ø´Â ¹Ì·¡ÁöÇâ ³×Æ®¿öÅ©·Î º¸Àå¹ÞÀ» ¼ö ÀÖ½À´Ï´Ù.

 

 

NGGSS-Network Diagram

 

 

±¤¹üÀ§ÇÑ °í±Þ °ü¸® ±â´É 
ÀÌ Stackable Smart SwitchµéÀ» º¸´Ù ¼Õ½±°í °£ÆíÇÏ°Ô °ü¸®ÇÒ ¼ö ÀÖ´Â ´Ù¾çÇÑ ¹æ¹ýÀÌ ÀÖ½À´Ï´Ù. ÀÌ Stackable Smart SwitchµéÀº ÀÌ ½ºÀ§Ä¡µé¿¡ ¹«·á·Î µ¿ºÀµÇ¾î ÀÖ´Â Smart Control Center Software¸¦ ÅëÇØ Á¦¾îµÉ ¼ö ÀÖÀ¸¸ç, À̸¦ ÅëÇØ ¸ðµç NETGEARÀÇ Smart SwitchµéÀ» Áß¾Ó¿¡¼­ Ž»öÇÏ°í °ü¸®Çϸç, ´ë·® ¼³Á¤ ¹× Æß¿þ¾î ¾÷±×·¹À̵尡 °¡´ÉÇÕ´Ï´Ù. ¸¸¾à ±Í»ç¿¡ ´Ù¸¥ NETGEAR ºñÁî´Ï½º Á¦Ç°µéÀÌ ÀÖ´Ù¸é NETGEARÀÇ ¸ðµç ³×Æ®¿öÅ© Á¦Ç°µéÀ» Ž»öÇÏ°í ¼³Á¤ÇÒ ¼ö ÀÖ´Â °ü¸® Ç÷§ÆûÀÎ NETGEAR NMS¸¦ »ç¿ëÇÒ ¼öµµ ÀÖ½À´Ï´Ù. ÀÌ Stackable Smart SwitchµéÀº NETGEARÀÇ Liftetime Çϵå¿þ¾î ǰÁú º¸ÁõÀ» ¾à¼ÓÇϰí ÀÖ½À´Ï´Ù.

Network Protocol and Standards Compatibility

  • IEEE 802.3 10BASE-T
  • IEEE 802.3u 100BASE-TX
  • IEEE 802.3ab 1000BASE-T
  • IEEE 802.3z 1000BASE-X
  • IEEE 802.3x full-duplex flow control
  • IEEE802.3az (EEE)
  • IEEE802.3af (DTE Power via MDI)
  • IEEE802.3at (DTE Power via MDI Enhancements)

Interfaces

GS728TS/GS752TS

  • 24/48 x 10/100/1000 Mbps copper ports
  • 2 x Combo ports to support 10/100/1000 Mbps copper ports or 1G/100M optical module
  • 2 x SFP slots (port 25 and 26) to support 1G optical module
  • 2 x SFP slots (port 27 and 28) to support 1G optical module (uplink) and 2.5G stacking (via stacking cable AGC761)
  • Auto-sensing and auto-negotiating capabilities for all copper ports
  • Auto UplinkTM on all ports to make the right connection

Administrative Switch Management

  • IEEE 8021.Q VLAN (256 groups, Static)
  • IEEE 802.1p Class of Service (CoS)
  • 8 hardware queues (1 is reserved for CPU; 7 queues are user configurable)
  • Port-based QoS
  • IEEE 802.3ad Static or Dynamic Link Aggregation (LACP)
  • IEEE 802.1D Spanning Tree Protocol
  • IEEE 802.1w Rapid Spanning Tree Protocol
  • IEEE 802.1s Multiple Spanning Tree Protocol
  • SNMP v1, v2c, v3
  • RFC 1213 MIB II
  • RFC 1643 Ethernet Interface MIB
  • RFC 1493 Bridge MIB
  • RFC 2131 DHCP client
  • IEEE 802.1x (RADIUS)
  • RADIUS accounting
  • IEEE 802.1x Dynamic VLAN Assignment
  • HTTPS/SSL: Secure HTTP GUI
  • Layer 3 (DSCP) Quality of Service (QoS)
  • TACACS+
  • TCP/UPD-based priority mapping
  • IGMP snooping v1, v2, v3
  • MLD Snooping
  • ACLs (MAC, IPv4, IPv6 and TCP/UDP based)
  • Storm control for broadcast, multicast and unknown unicast packets
  • Port-based ingress/egress rate limiting
  • SNTP
  • DNS
  • DoS and Auto DoS prevention
  • IPv6 management, multicast and QoS
  • Static Routing
  • DHCP Snooping
  • Green Features:
    • EEE (Energy Efficient Ethernet) compliance
    • Lower power consumption during link-down or idle mode or with shorter cable length
  • Protocol and MAC based VLAN
  • RMON group 1, 2, 3, 9
  • Private Enterprise MIB
  • Port mirroring – many-to-one
  • IEEE 802.3ab LLDP
  • LLDP-MED
  • Protected ports
  • Cable test
  • Smart Control Center discovery
  • Web-based configuration
  • Configuration backup/restore
  • Password access control
  • Firmware upgradeable

Performance Specifications

  • Forwarding modes: Store-and-forward
  • Bandwidth (per unit): 56 Gbps for GS728TS/TPS, 104 Gbps for GS752TS/TPS
  • Stacking up to 6 switches or 300 ports per stack
  • Mix and match stacking supported on the GS7xxTS/GS7xxTPS family (GS728TS, GS752TS, GS728TPS and GS752TPS)
  • Stacking bandwidth: 5 Gbps (bidirectional)
  • Network latency: Less than 20 microseconds for 64-byte frames in store-and-forward mode for 1000 Mbps to 1000 Mbps transmission
  • Buffer memory: 2 MB
  • 128Mbytes System DDR SDRAM (32Mbx16)
  • 32Mbytes Flash size
  • Address database size: 16K media access control (MAC) addresses per system
  • Addressing: 48-bit MAC address
  • Number of VLANs is 256; Maximum VLAN id is 4093
  • Number of 802.1p traffic classes is 7
  • Number of LAGs is 8
  • Number of static routes is 32
  • Number of routed VLANs is 15
  • Number of ARP Cache entries size is 1024
  • Queues used for DiffServ is 7
  • Number of ACLs (IPv4/IPv6) is 100
  • Number of DHCP snooping binding is 8K
  • Number of DHCP static entries is 1024
  • Mean time between failures (MTBF):
    • GS728TS:
      • 595422.68 hours (~68.9 years) at 25¡ÆC
      • 174069.75 hours (~20.1 years) at 55¡ÆC
    • GS728TPS:
      • 530911.26 hours (~62.3 years) at 25¡ÆC
      • 153808.90 hours (~17.8 years) at 55¡ÆC
    • GS752TS:
      • 303219.7 hours (~35.1 years) at 25¡ÆC
      • 102616.4 hours (~11.8 years) at 55¡ÆC
    • GS752TPS:
      • 206539.3 hours (~23.9 years) at 25¡ÆC
      • 67929.0 hours (~7.8 years) at 55¡ÆC

LEDs

  • Per RJ-45 port: Speed/Link/Activity
  • Per SFP port: Speed/Link/Activity
  • Per device: Power, Fan, Stack Master, Stack ID
  • Per device (for GS728TPS/GS52TPS): LED mode and PoE Max

Power Supply

  • GS728TS
    • AC Voltage: 100-240 V
    • Frequency: 50-60 Hz
    • Amperage (max): 1.4A
    • Max Power consumption: 29.7W
  • GS752TS
    • AC Voltage: 100-240 V
    • Frequency: 50-60 Hz
    • Amperage (max): 1.4A
    • Max Power consumption: 77W

Physical Specifications

  • GS728TS
    • Dimensions (W x D x H): 440 x 257 x 43 mm
    • Weight: 3.34 kg
  • GS752TS
    • Dimensions (W x D x H): 440 x 257 x 43 mm
    • Weight: 3.88 kg
Environmental Specifications
  • Operating temperature: 32¡Æ to 104¡Æ F (0¡Æ to 50¡Æ C)
  • Storage temperature: -4¡Æ to 158¡Æ F (-20¡Æ to 70¡Æ C)
  • Operating humidity: 10% to 90% maximum relative humidity, non-condensing
  • Storage humidity: 5% to 95% maximum relative humidity, non-condensing

Electromagnetic Compliance

  • CE mark, commercial
  • FCC Part 15 Class A
  • VCCI Class A
  • EN 55022 (CISPR 22),
  • EN 55024 (CISPR 24)
  • C-Tick
  • CCC
  • KCC

Safety

  • CE mark, commercial
  • CUL 60950 (Listed)/EN 60950 (Low Voltage Directive)
  • CB
  • CCC

System Requirements

  • Category 5 UTP Network cables or better
  • Network card for each PC
  • Network software (e.g., WindowsXP, IE7+, Firefox3+)

Warranty

  • NETGEAR Lifetime Warranty¢Ó

ProSupportTM Service Packs Available

  • XPressHW, Category 2: PRR0332 (3-year next-business day hardware replacement contract)
  • OnCall 24x7, Category 2: PMB0332 (3-year Advanced Technical Support contract, including Remote Diagnostics performed by our technical experts for prompt resolution of technical issues, and next-business day hardware replacement)

Package Contents

  • ProSafe¢ç Gigabit Stackable Smart Switch GS728TS
  • Rubber footpads
  • Power cord
  • Rack-mount kit
  • Resource CD installation guide
  • Warranty/support information card

Supported Modules

  • AGC761 1m 1G/2.5G Direct Attach SFP Cable
  • AGM731F ProSafe 1000BASE-SX SFP GBIC
  • AGM732F ProSafe 1000BASE-LX SFP GBIC
  • AFM735 ProSafe 100Base-FX SFP LC GBIC

Ordering Information

  • GS728TS
    • North America: GS728TSB-100NAS
    • Europe: GS728TSB-100EUS
    • Asia/Japan: GS728TSB-100AJS
  • GS752TS
    • North America: GS752TSB-100NAS
    • Europe: GS752TSB-100EUS
    • Asia/Japan: GS752TSB-100AJS


GS728TS Product Online Catalog - KOR