º¸¾È Á¢¼Ó ·Î±×ÀÎ | ȸ¿ø°¡ÀÔ | Àå¹Ù±¸´Ï | °í°´¼¾ÅÍ
TEL : 02-798-9114
HPE-ARUBA[ÆÄ°Ý°¡]
CISCO [ƯÆǸðµ¨]
D-Link [Àü±¹ÃÖÀú°¡]
NETGEAR [ÃÖÀú°¡°ø±Þ]
Alcatel-Lucent Enterprise
½Ã½ºÄÚ Cisco
Cisco SB/Pro
ZyXEL
APC[ÀüÈ­¹®ÀÇ]
¼ÖÅØ(Soltech)
TP-LINK
¿¡ÀÌÅÙ[ATEN]
µðÆ÷±×(Defog)
DASAN(´Ù»ê)
UTM/VPN/¹æÈ­º®
ETK
¹«¼±·£/Wireless
¹«¼±°øÀ¯±â/¹«¼±AP/¾ÈÅ׳ª
À¯¼±Àåºñ/Network
½ºÀ§Ä¡/·£Ä«µå/ÇÁ¸°Åͼ­¹ö
POE ½ºÀ§Ä¡
10±â°¡ºñÆ® ÀÌ´õ³Ý
·£°ø±¸,CCTV ÀâÀÚÀç
FIBER Àåºñ/Á¡ÆÛÄÚµå
RACK/UPS/KVM
°¢Á¾ÄÉÀ̺í/Á¨´õ
¿µ»ó/À½Çâ/ºÐ¹è±â/°øÀ¯
½Ã¸®¾ó Åë½ÅÁ¦Ç°
¸ÖƼÆ÷Æ®/ÄÁ¹öÅÍ
»ê¾÷¿ë Á¦Ç°±º
CCTV ºñµð¿À¼­¹ö
USB/1394/ÁÖº¯±â±â
======================
AP
HIKVISION
INTEL
MOXA
Chesio (10G NIC)
IPTIME
Uniclass KVM
TYCO(AMP)
3COM
Britz
======================
°¡°ÝÁ¶Á¤
======================
802.11N
UBIQUITI
·£Àåºñ ¼Ò½Ä/¹®ÀÇ
°ø±Þ/±¸Ãà»ç·Ê
(ÁÖ)·£Àåºñ ÀÚ·á½Ç
 
ºñ¹Ð¹øÈ£ È®ÀÎ ´Ý±â
À¯¼±Àåºñ/Network
½ºÀ§Ä¡/·£Ä«µå/ÇÁ¸°Åͼ­¹ö
À¯¼±Àåºñ/Network
½ºÀ§Ä¡/·£Ä«µå/ÇÁ¸°Åͼ­¹ö
> ½Ã½ºÄÚ ½ºÀ§Ä¡ > CISCO WS-CE500-24TT - 24P 10/100 + 2P 1000 Switch Hub
     
 ÀÌÀü»óÇ° CISCO WS-CE500-24TT - 24P 10/100 + 2P 1000 Switch Hub ´ÙÀ½»óÇ°
 
 
     
Á¦Á¶È¸»ç : CISCO
ÆǸŰ¡°Ý : 715,000¿ø
¼ö·® EA
 
 
 
 
 
 
 
 
 
»óÇ° »ó¼¼ ¼³¸í
 
 

Cisco Catalyst Express 500 ½Ã¸®Áî ½ºÀ§Ä¡



Á¦Ç°°³¿ä


Cisco¢ç Catalyst¢ç 500 ½Ã¸®Áî ½ºÀ§Ä¡´Â 250¸í ÀÌÇÏÀÇ Á÷¿øÀ» º¸À¯ÇÑ ±â¾÷ü¸¦ À§ÇØ ½Ã½ºÄÚÀÇ ¸ÂÃãÈ­µÈ ³×Æ®¿öÅ·À» Á¦°øÇÕ´Ï´Ù. Cisco Systems¢ç ±â¼ú¿¡ ÀÇÇØ °­È­µÈ Layer 2-managed Fast Ethernet ¹× Gigabit Ethernet ½ºÀ§Ä¡ Á¦Ç°±ºÀº µ¥ÀÌÅÍ, ¹«¼± ¹× À½¼º¿¡ ÃÖÀûÈ­µÈ ¾ÈÀüÇÑ ³×Æ®¿öÅ© ±â¹ÝÀÇ nonblocking wired-speed ¼º´ÉÀ» Á¦°øÇÕ´Ï´Ù. ¶ÇÇÑ °í±Þ º¸¾È ±â´ÉÀÌ ³»ÀåµÇ¾î ÀÖ¾î ±ÍÇÏÀÇ Àåºñ¿Í ³×Æ®¿öÅ©¸¦ È®½ÇÈ÷ º¸È£ÇØ ÁÝ´Ï´Ù.

´©±¸³ª ½±°Ô »ç¿ëÇÒ ¼ö ÀÖ´ÂGUI ´Â ³×Æ®¿öÅ©ÀÇ ¼³Á¤, ½ÇÇà ¹× ¹®Á¦ ÇØ°áÀ» ´Ü¼øÈ­ÇÕ´Ï´Ù. Cisco Smartport´Â »çÀü¿¡ ¼³Á¤µÈ ½Ã½ºÄÚ ±ÇÀå ³×Æ®¿öÅ© ±¸¼º, ¼­ºñ½º Ç°Áú (QoS), º¸¾È ¹× ¸ÖƼij½ºÆ® ¼³Á¤À» ÅëÇØ µ¥ÀÌÅÍ, ºñµð¿À, IP Åë½Å ¹× ¹«¼± LAN ¾ÖÇø®ÄÉÀ̼ÇÀÇ ÅëÇÕÀ» Áö¿øÇÕ´Ï´Ù. Cisco Smartports ±â¼úÀº ¾÷¹«¿¡ ÇʼöÀûÀÎ Æ®·¡ÇÈ ¿ì¼± ¼øÀ§¸¦ °áÁ¤ÇÏ°í ±ú²ýÇÑ À½¼º Ç°ÁúÀ» Áö¿øÇϸç, ´ë¿ë·® ´ë¿ªÆøÀÇ ºñµð¿À Æ®·¡ÇÈÀÌ ÇØ´ç ³×Æ®¿öÅ©ÀÇ ´Ù¸¥ ¾ÖÇø®ÄÉÀ̼ǿ¡ ¿µÇâÀ» ÁÖÁö ¾Êµµ·Ï ÇÔÀ¸·Î½á ¾ÈÀüÇÑ ¹«¼± ³×Æ®¿öÅ©¸¦ º¸ÀåÇÕ´Ï´Ù. ½ºÀ§Ä¡ ³»ºÎÀÇ ÅëÇÕ ÀÎÅÚ¸®Àü½º´Â ±Í»çÀÇ ºñÁî´Ï½º¿¡ ¿µÇâÀ» ¹ÌÄ¡±â Àü¿¡ Àåºñ ¹× ³×Æ®¿öÅ© ¹®Á¦¸¦ °¨ÁöÇϵµ·Ï µµ¿ÍÁÝ´Ï´Ù.

°¢ ½ºÀ§Ä¡¸¦ ³»ÀåÇü GUI ÀåÄ¡ °ü¸®ÀÚ¸¦ ÅëÇØ °ü¸®Çϰųª ³×Æ®¿öÅ©¸¦ PC ±â¹ÝÀÇ °í±Þ ³×Æ®¿öÅ© °ü¸® ¾ÖÇø®ÄÉÀ̼ÇÀÎ Cisco Network Assistant¸¦ ÅëÇØ °ü¸®ÇÒ ¼ö ÀÖ½À´Ï´Ù. Cisco Network Assistant´Â ½Ã½ºÄÚ ½ºÀ§Ä¡, ±×¸®°í ¶ó¿ìÅÍ ¹× ¹«¼± ¾×¼¼½º Æ÷ÀÎÆ® µîÀÇ ±âŸ ½Ã½ºÄÚ Àåºñ¿¡ ´ëÇØ Áß¾Ó ÁýÁᫎ °ü¸® ¹× ±¸¼ºÀ» Á¦°øÇÕ´Ï´Ù. Cisco Network Assistant¸¦ »ç¿ëÇÏ¸é µ¿½Ã¿¡ ´ÙÁßÀûÀÎ ½ºÀ§Ä¡¸¦ ±¸¼ºÇÏ´Â °Í ÀÌ¿Ü¿¡µµ, ½Ã½ºÄÚ ¹«¼± ¾×¼¼½º Æ÷ÀÎÅ͸¦ ±¸¼ºÇÏ°í ½Ã½ºÄÚ ¶ó¿ìÅÍ ¹× ¾×¼¼½º Æ÷ÀÎÆ®»ó¿¡¼­ ÀåÄ¡ °ü¸®ÀÚ¸¦ È£ÃâÇÒ ¼ö ÀÖ½À´Ï´Ù. ½Ã½ºÄÚ ½ºÀ§Ä¡, ¶ó¿ìÅÍ ¹× ¹«¼± ¾×¼¼½º Æ÷ÀÎÆ®¿¡ ´ëÇÑ ¼ÒÇÁÆ®¿þ¾î ¾÷±×·¹À̵å´Â µå·¡±×-¾Ø-µå·Ó ¹æ½Äó·³ °£´ÜÇÏ°Ô ¼öÇàµË´Ï´Ù. Cisco Network Assistant´Â ½Ã½ºÄÚ À¥ »çÀÌÆ®ÀÎ http://www.cisco.com/go/cna¿¡¼­ ¹«·á·Î ´Ù¿î¹ÞÀ» ¼ö ÀÖ½À´Ï´Ù.

¶ÇÇÑ, Cisco Catalyst Express 500 ½Ã¸®Áî ½ºÀ§Ä¡´Â PoE(Power over Ethernet)¸¦ Á¦°øÇÏ¿© IP Ä¿¹Â´ÏÄÉÀÌ¼Ç ¹× ¹«¼± LAN ¹èÄ¡¿¡ ÇÊ¿äÇÑ ºñ¿ë ¹× º¹À⼺À» °¨¼Ò½Ãŵ´Ï´Ù. PoE´Â ½ºÀ§Ä¡°¡ Category 5 ÄÉÀ̺íÀ» ÅëÇØ Àü¿ø °ø±Þ ¹× µ¿½Ã¿¡ ÀÌ´õ³Ý ¿¬°á¼ºÀ» ¹«¼± ¾×¼¼½º Æ÷ÀÎÆ®, CCTV Ä«¸Þ¶ó ¹× IP Æù°ú °°Àº ÀζóÀÎ Àü¿ø Àåºñ¿¡ Á¦°øÇÒ ¼ö ÀÖµµ·Ï Áö¿øÇÏ´Â °í±Þ ±â¼úÀÔ´Ï´Ù. PoE Æ÷Æ®´Â ÀζóÀÎ Àü¿ø Àåºñ¿¡ Àü¿ø Äܼ¾Æ®³ª ÄÉÀ̺íÀ» Ãß°¡ÀûÀ¸·Î »ç¿ëÇÏ´Â µ¥ ÇÊ¿äÇÑ ºñ¿ë°ú º¹À⼺ ¹®Á¦¸¦ Á¦°ÅÇÕ´Ï´Ù. Cisco Catalyst Express 500 Series¿¡´Â 4°¡Áö ¸ðµ¨ÀÌ ÀÖ½À´Ï´Ù. (±×¸² 1 ¹× Ç¥ 1).

±×¸² 1. Cisco Catalyst Express 500 Series



Ç¥ 1. Cisco Catalyst Express 500 Series ¸ðµ¨

Á¦Ç°¸í / (SKU) ¼³¸í
Cisco Catalyst Express 500-24TT (WS-CE500-24TT) - µ¥½ºÅ©Å¾ ¿¬°áÀ» À§ÇÑ 24°³ÀÇ 10/100 Æ÷Æ®
- ¾÷¸µÅ© ¶Ç´Â ¼­¹ö ¿¬°áÀ» À§ÇÑ 2°³ÀÇ 10/100/1000BASE-T Æ÷Æ®
Cisco Catalyst Express 500-24LC (WS-CE500-24LC) - µ¥½ºÅ©Å¾ ¿¬°áÀ» À§ÇÑ 20°³ÀÇ 10/100 Æ÷Æ®
- µ¥½ºÅ©Å¾, ¹«¼± ¾×¼¼½º Æ÷ÀÎÆ®, IP ÅÚ·¹Æ÷´Ï ¶Ç´Â CCTV Ä«¸Þ¶ó ¿¬°áÀ» À§ÇÑ 4°³ÀÇ 10/100 PoE Æ÷Æ®
- ¾÷¸µÅ© ¶Ç´Â ¼­¹ö ¿¬°áÀ» À§ÇÑ 2°³ÀÇ 10/100/1000BASE-T ¶Ç´Â SFP(Small Form-Factor Pluggable) Æ÷Æ®
Cisco Catalyst Express 500-24PC (WS-CE500-24PC) - µ¥½ºÅ©Å¾, ¹«¼±, IP ÅÚ·¹Æ÷´Ï ¶Ç´Â CCTV Ä«¸Þ¶ó ¿¬°áÀ» À§ÇÑ 24°³ÀÇ 10/100 PoE Æ÷Æ®
- ¾÷¸µÅ© ¶Ç´Â ¼­¹ö ¿¬°áÀ» À§ÇÑ 2°³ÀÇ 10/100/1000BASE-T ¶Ç´Â SFP Æ÷Æ®
Cisco Catalyst Express 500G-12TC (WS-CE500G-12TC) - ½ºÀ§Ä¡ ÅëÇÕ ¶Ç´Â ¼­¹ö ¿¬°áÀ» À§ÇÑ 8°³ÀÇ 10/100/1000BASE-T ¹× 4°³ÀÇ 10/100/1000BASE-T ¶Ç´Â SFP Æ÷Æ®


±×¸² 2´Â Cisco Catalyst Express 500 ½Ã¸®Áî ½ºÀ§Ä¡¿Í ÀüÇüÀûÀÎ ¹èÄ¡ ½Ã³ª¸®¿À¸¦ ³ªÅ¸³À´Ï´Ù.

±×¸² 2. ÀüÇüÀûÀÎ Cisco Catalyst Express 500 ½Ã¸®Áî ½ºÀ§Ä¡ ¹èÄ¡ ½Ã³ª¸®¿À



ÁÖ¿ä ÀÌÁ¡

¼º´É
¸ðµç Æ÷Æ®¿¡ nonblocking wired-speed ½ºÀ§ÄªÀ» Áö¿øÇÏ´Â Cisco Catalyst Express 500 Series´Â µ¥½ºÅ©Å¾, ¹«¼± ¾×¼¼½º Æ÷ÀÎÆ®, ÇÁ¸°ÅÍ ¹× IP Æù ¿¬°á¼ºÀ» À§ÇØ 10-/100-Mbps Æ÷Æ®¸¦ Á¦°øÇϸç, ¼­¹ö ¶Ç´Â ¹éº» ¿¬°áÀ» À§Çؼ­´Â 10/100/1000BASE-T ¶Ç´Â SFP Æ÷Æ®¸¦ Á¦°øÇÕ´Ï´Ù. ¶ÇÇÑ HOL(Head-of-Line) ºí·°Å· ±â´ÉÀ» °®Ãß°í ÀÖÀ¸¹Ç·Î, ƯÁ¤ Æ÷Æ®ÀÇ È¥ÀâÀÌ ÇØ´ç ½ºÀ§Ä¡»ó¿¡¼­ ´Ù¸¥ Æ÷Æ®ÀÇ ¼º´É¿¡ ¿µÇâÀ» ÁÖÁö ¾Ê½À´Ï´Ù.

»ç¿ë ¿ëÀ̼º
Cisco Catalyst Express 500 ½Ã¸®Áî ½ºÀ§Ä¡´Â ¼Õ½¬¿î »ç¿ëÀ» À§ÇØ ¼³°èµÇ¾ú½À´Ï´Ù. GUI ÀåÄ¡ °ü¸®ÀÚ¸¦ ÅëÇØ ½ºÀ§Ä¡ÀÇ ÃʱâÈ­°¡ ÀÌ·ç¾îÁö¹Ç·Î ÄÜ¼Ö ÄÉÀÌºí ¶Ç´Â Å͹̳Π¿¡¹Ä·¹ÀÌ¼Ç ¾ÖÇø®ÄÉÀ̼ÇÀÌ ºÒÇÊ¿äÇÕ´Ï´Ù. ÅëÇÕµÈ ÀÎÅÚ¸®Àü½º´Â ½Ã½ºÅÛ ¼öÁØÀ¸·Î ½ºÀ§Ä¡¸¦ ÃÖÀûÈ­Çϸç, Cisco Smartports´Â 10°¡ÁöÀÇ ¹Ì¸® ¼³Á¤µÈ ¿ªÇÒµé Áß¿¡¼­ ¼±ÅÃÇÔÀ¸·Î½á °¢ Æ÷Æ®¿¡ ´ëÇÑ ÃÖÀûÈ­ ±¸¼ºÀÌ °¡´ÉÇÕ´Ï´Ù. ¸ðµç PoE Æ÷Æ®´Â IEEE Ç¥ÁØÀ» ÃÖ´ë 15.4W±îÁö µ¿½Ã¿¡ °ø±ÞÇÒ ¼ö ÀÖ½À´Ï´Ù. »Ó¸¸ ¾Æ´Ï¶ó Àü¿ø¿¡ ´ëÇÑ ¿¹»êÀ» ¼¼¿ì°Å³ª Àü¿ø Á¦ÇÑÀ» ÃÊ°úÇÏÁö ¾ÊÀ»Áö, ¿ÜÀåÇü Àü¿ø °ø±Þ ÀåÄ¡¸¦ Ãß°¡ÇØ¾ß ÇÒÁö µîÀÇ ¹®Á¦·Î °í¹ÎÇÒ ÇÊ¿ä°¡ ¾ø½À´Ï´Ù. ¸ðµç Æ÷Æ®´Â Æ÷Æ® ¼Óµµ ¹× ÀÌÁß ¼³Á¤¿¡ ´ëÇÏ¿© autonegotiationÀ» Áö¿øÇÕ´Ï´Ù. Auto-MDIX(Automatic Medium-dependent Interface Crossover) °¨Áö Áö¿ø ±â´ÉÀÌ Á¦°øµÇ¹Ç·Î, ºÎÀûÇÕÇÑ ÄÉÀ̺í Á¾·ù¿¡ ´ëÇؼ­µµ °ÆÁ¤ÇÒ ÇÊ¿ä°¡ ¾ø½À´Ï´Ù.

È¿À²¼º
Cisco Catalyst Express 500 ½Ã¸®Áî ½ºÀ§Ä¡ÀÇ °æ¿ì, ¿£µåÅõ¿£µå ½Ã½ºÄÚ ³×Æ®¿öÅ©ÀÇ ¹èÄ¡ ¹× ½ÇÇà ÀÛ¾÷ÀÌ ¸Å¿ì ½¬¿öÁ³½À´Ï´Ù. Cisco Smartports Advisor¸¦ ÅëÇØ Cisco Catalyst Express 500 ½Ã¸®Áî ½ºÀ§Ä¡´Â ¿¬°áµÈ ½Ã½ºÄÚ ÀåºñµéÀ» ÀÚµ¿ Ž»öÇÏ¿© ÀûÇÕÇÑ Smartport ¿ªÇÒÀ» ±ÇÀåÇÕ´Ï´Ù. Smartports Æù ¹× µ¥½ºÅ©Å¾ ¿ªÇÒÀ» ÅëÇØ À½¼º Ç°ÁúÀÌ º¸ÀåµË´Ï´Ù. ´ë¿ë·®ÀÇ ÆÄÀÏ ¼Û¼ö½Å ¹× ´Ù¿î·Îµå·Î ÀÎÇØ ÀüÈ­ ´ëÈ­°¡ ¿µÇâÀ» ¹ÞÁö ¾Ê½À´Ï´Ù. ¶ÇÇÑ, À߸øµÈ ±¸¼ºÀ» ÀÚµ¿ ŽÁöÇÏ°í ±× ÇØ°á ¹æ¹ýÀ» Á¦¾ÈÇÕ´Ï´Ù.

º¸¾È¼º
Cisco Catalyst Express 500 ½Ã¸®Áî ½ºÀ§Ä¡´Â ±Í»çÀÇ ºñÁî´Ï½º¸¦ º¸È£Çϱâ À§ÇÏ¿© ¿©·¯ °èÃþÀÇ º¸¾È ±â´ÉÀ» Á¦°øÇÕ´Ï´Ù. GUI ÀåÄ¡ °ü¸®ÀÚ¸¦ Åë°úÇÏ´Â °ü¸® Æ®·¡ÇÈÀ» SSL(Secure Sockets Layer) ¹× SNMPv3(Simple Network Management Protocol Version 3)·Î ¾ÏȣȭÇÏ¿© º¸¾ÈÀ» À¯ÁöÇÕ´Ï´Ù. ¶ÇÇÑ ³×Æ®¿öÅ© º¸¾ÈÀ» À§ÇØ, ºñÁî´Ï½º¿¡ ÃÖÀûÈ­µÈ 3°¡Áö º¸¾È ¼öÁØ Áß¿¡¼­ ¼±ÅÃÀÌ °¡´ÉÇÕ´Ï´Ù. »Ó¸¸ ¾Æ´Ï¶ó, Cisco Aironet ¹«¼± ¾×¼¼½º Æ÷ÀÎÆ®¿Í±ä¹ÐÈ÷ ÅëÇÕÇÔÀ¸·Î½á ¾ÈÀüÇÑ ¹«¼± LAN ³×Æ®¿öÅ©¸¦ ½±°í ºü¸£°Ô ¹èÄ¡ÇÒ ¼ö ÀÖ½À´Ï´Ù. Cisco Self-Defending Network ¹× Cisco Clean Access ¼Ö·ç¼ÇÀ» ÅëÇØ, Cisco Catalyst Express 500 Series´Â º¸´Ù ½±°Ô ±Í»çÀÇ ³×Æ®¿öÅ©¸¦ ¹ÙÀÌ·¯½º·ÎºÎÅÍ º¸È£ÇÒ ¼ö ÀÖµµ·Ï ÇØÁÖ¸ç, ³×Æ®¿öÅ©ÀÇ Àü¹ÝÀûÀÎ º¸¾È ¼öÁØÀ» ÇÑÂ÷¿ø Çâ»ó½ÃÄÑ ÁÝ´Ï´Ù.

¼Õ½¬¿î ¸ð´ÏÅ͸µ ¹× ¹®Á¦ÇØ°á
ÄÉÀ̺í ÀÛ¾÷»óÀÇ ¹®Á¦, ÀϹÝÀûÀÎ ±¸¼º»óÀÇ ¿À·ù ¹× ±âŸ ÀáÀçÀûÀÎ ³×Æ®¿öÅ© ¹®Á¦¸¦ ÆľÇÇÏ´ÂCisco One-Click ¹®Á¦ÇØ°á ÅøÀ» ÅëÇØ ¹®Á¦ ÇØ°áÀÌ ÇÑÃþ ´õ ½¬¿öÁ³½À´Ï´Ù. ±×·¡ÇÁ Ãß¼¼ ºÐ¼®Ç¥ ¹× Alert LED´Â ³×Æ®¿öÅ©°¡ Àå¾Ö¸¦ ÀÏÀ¸Å°±â Àü¿¡ ¹®Á¦¸¦ ÆľÇÇÒ ¼ö ÀÖµµ·Ï µµ¿ÍÁÝ´Ï´Ù.

Á¦ÇѺ¸Áõ
Cisco Catalyst Express 500 Series¿¡´Â Á¦ÇѺ¸Áõ ¼­ºñ½º°¡ Æ÷ÇԵǾî ÀÖ½À´Ï´Ù. ÀÚ¼¼ÇÑ ³»¿ëÀº http://www.cisco.com¿¡¼­ ÂüÁ¶ÇϽʽÿÀ.

Á¦Ç° »ç¾ç

Ç¥2´Â Cisco Catalyst Express 500 ½Ã¸®Áî ½ºÀ§Ä¡ÀÇ »ç¾çÀ» ¼³¸íÇÑ °ÍÀÔ´Ï´Ù.

Ç¥ 2. Cisco Catalyst Express 500 ½Ã¸®Áî ½ºÀ§Ä¡ »ç¾ç

±â´É ¼³¸í
¼º´É
Æ÷¿öµù ¼Óµµ - Cisco Catalyst Express 500-24TT, Catalyst Express 500-24LC ¹× Catalyst Express 500-24PC -8.8 Gbps
- Cisco Catalyst Express 500G-12TC-24Gbps
  - Cisco Catalyst Express 500-24TT, Catalyst Express 500-24LC ¹× Catalyst Express 500-24PC-6.6Mpps wire-speed ¼º´É
- Cisco Catalyst Express 500G-12TC-18Mpps wire-speed ¼º´É
·¹À̾î 2 ½ºÀ§Äª
MAC ÁÖ¼Ò
- 8000 MAC ÁÖ¼Ò
VLAN °³¼ö
- 32°³ÀÇ VLAN(1000 ¹üÀ§)
Å¥(Queue)ÀÇ °³¼ö ¹× À¯Çü - Æ÷Æ®´ç 4°³ÀÇ Å¥(Queue) Á¦°ø
- SRR(Shaped Round Robin) Queuing
Smartports (¹Ì¸® ¼³Á¤µÈ ½Ã½ºÄÚ ±ÇÀå ³×Æ®¿öÅ© °³¼±»çÇ×, QoS ¹× º¸¾È)
µ¥½ºÅ©Å¾
Æ÷Æ®°¡ ÃÖÀûÀÇ µ¥½ºÅ©Å¾ ¼º´ÉÀ» À§ÇØ ±¸¼ºµÇ¾î ÀÖ½À´Ï´Ù.
ÀüÈ­ ¹× µ¥½ºÅ©Å¾ ¼±¸íÇÑ À½¼º ´ëÈ­¸¦ º¸ÀåÇϱâ À§ÇØ À½¼º Æ®·¡ÇÈ¿¡ ´ëÇÑ ¿ì¼± ¼øÀ§¸¦ ºÎ¿©ÇÕ´Ï´Ù.
¶ó¿ìÅÍ Æ÷Æ®°¡ WAN ¿¬°áÀ» À§ÇÏ¿© ¶ó¿ìÅÍ ¶Ç´Â ¹æÈ­º®¿¡ ´ëÇØ ÃÖÀûÀÇ ¿¬°á·Î ±¸¼ºµÇ¾î ÀÖ½À´Ï´Ù.
½ºÀ§Ä¡ Æ÷Æ®°¡ ½Å¼ÓÇÑ ÄÁ¹öÁ¯½º¸¦ À§ÇØ ¹éº» ½ºÀ§Ä¡ ¿¬°á¿ë ¾÷¸µÅ© Æ÷Æ®·Î ±¸¼ºµÇ¾î ÀÖ½À´Ï´Ù.
¾×¼¼½º Æ÷ÀÎÆ® Æ÷Æ®°¡ ¹«¼± ¾×¼¼½º Æ÷ÀÎÆ®¿¡ ´ëÇÑ ÃÖÀûÀÇ ¿¬°á·Î ±¸¼ºµÇ¾î ÀÖ½À´Ï´Ù.
¼­¹ö ½Å·Ú¼º ÀÖ°í ÇʼöÀûÀÎ ºñÁî´Ï½º ¶Ç´Â Ç¥ÁØÀ¸·Î¼­ ¼­¹ö´Â ¿ì¼± ¼øÀ§°¡ µÉ ¼ö ÀÖ½À´Ï´Ù.
ÇÁ¸°ÅÍ Æ÷Æ®°¡ ÇÁ¸°ÅÍ Æ®·¡ÇÈÀÌ ¾÷¹«¿¡ ÇʼöÀûÀÎ Æ®·¡ÇÈ ¹× À½¼º Æ®·¡ÇÈ¿¡ ¿µÇâÀ» ÁÖÁö ¾Êµµ·Ï ÃÖÀûÈ­µÇ¾î ÀÖ½À´Ï´Ù.
°Ô½ºÆ® °Ô½ºÆ®´Â ÀÎÅͳݿ¡ ¾×¼¼½ºÇÒ ¼ö´Â ÀÖÀ¸³ª, ȸ»ç ³×Æ®¿öÅ©¿¡ ´ëÇؼ­´Â ¾×¼¼½º°¡ ºÒ°¡´ÉÇÕ´Ï´Ù.
Áø´Ü °í°´ÀÌ Áø´Ü Àåºñ¸¦ ¿¬°áÇÏ¿© ´Ù¸¥ ½ºÀ§Ä¡»óÀÇ Æ®·¡ÇÈÀ» ¸ð´ÏÅ͸µÇÒ ¼ö ÀÖ½À´Ï´Ù(Cisco Network Assistant·Î¸¸ ±¸¼º °¡´É).
±âŸ °í°´ÀÌ VLANÀ» ±¸¼ºÇÒ ¼ö ÀÖ½À´Ï´Ù.
º¸¾È
·¹º§ º¸¾È ¼öÁØ¿¡´Â ´ÙÀ½ 3°¡Áö°¡ ÀÖ½À´Ï´Ù. Àú, Áß, °í(Cisco Network Assistant·Î¸¸ ±¸¼º °¡´É)
- Àú-Á¦ÇÑÀûÀÎ °Ô½ºÆ® ¾×¼¼½º¸¸ ÀÖ´Â ±â¾÷ ȯ°æ¿ë
- Áß-º¸¾ÈÀÌ Áß¿äÇÑ È¯°æ¿¡ ÀÖ´Â ¾÷ü¿ëÀ¸·Î¼­, Çã¿ëµÈ Àåºñ¸¸ ȸ»ç ³×Æ®¿öÅ©¿¡ ¾×¼¼½º °¡´É
- °í-º¸¾ÈÀÌ ÇʼöÀûÀΠȯ°æ¿¡ ÀÖ´Â ¾÷ü¿ëÀ¸·Î¼­, Çã¿ëµÈ Àåºñ¿Í ÀÎÁõµÈ »ç¿ëÀÚ¸¸ ȸ»ç ³×Æ®¿öÅ©¿¡ ¾×¼¼½º °¡´É
¸ÖƼij½ºÆ® °í´ë¿ªÆøÀÇ ºñµð¿À Æ®·¡ÇÈÀÌ ÇØ´ç ³×Æ®¿öÅ©»óÀÇ ´Ù¸¥ ¾ÖÇø®ÄÉÀ̼ǿ¡´Â ¿µÇâÀ» ÁÖÁö ¾Êµµ·Ï ÃÖÀûÈ­µÇ¾î ÀÖ½À´Ï´Ù.
ÀζóÀÎ Àü·Â(PoE) Cisco Catalyst Express 500-24PCÀÇ 24°³ PoE Æ÷Æ®µéÀÌ ¸ðµÎ ÃÖ´ë 15.4W(IEEE 802.3af ÃÖ´ë Ç¥ÁØ)ÀÇ Àü·ÂÀ» Category 5 ÄÉÀ̺íÀ» ÅëÇØ °ø±ÞÇÏ¿©, ÃÑ 370WÀÇ ÀζóÀÎ Àü·ÂÀ» »ý»êÇÒ ¼ö ÀÖ½À´Ï´Ù. Cisco Catalyst Express 500-24LC ½ºÀ§Ä¡¿¡ ÀÖ´Â 4°³ÀÇ Æ÷Æ®µéÀÌ ¸ðµÎ ÃÖ´ë 15.4WÀÇ Àü·ÂÀ» Category 5 ÄÉÀ̺íÀ» ÅëÇØ °ø±ÞÇÏ¿© ÃÖ´ë 62WÀÇ ÀζóÀÎ Àü·ÂÀ» »ý»êÇÒ ¼ö ÀÖ½À´Ï´Ù.
IEEE 802.3af PoE Ç¥ÁØ°ú Cisco Prestandard ÀζóÀÎ Àü¿ø µÎ °¡Áö ¸ðµÎ Áö¿øµË´Ï´Ù.
Á¦Ç° »ç¾ç
Áö¿ø Ç¥ÁØ - IEEE 802.1d Spanning Tree Protocol
- IEEE 802.1p ¼­ºñ½º µî±Þ(CoS) ºÐ·ù
- IEEE 802.1q VLAN
- IEEE 802.1w Rapid Convergence Spanning Tree Protocol
- IEEE 802.1x Æ÷Æ® ¾×¼¼½º ÀÎÁõ
- LACP(IEEE 802.3ad Link Aggregation Control Protocol)
- IEEE 802.3af PoE(Power over Ethernet)
- 10BASE-T, 100BASE-TX ¹× 1000BASE-T Æ÷Æ®»ó¿¡¼­ Full-Duplex IEEE 802.3x
- IEEE 802.10BASE-T
- IEEE 802.3u 100BASE-T
- IEEE 802.3ab 1000BASE-T
- IEEE 802.3z 1000BASE-X
- IGMP (v1, v2 ¹× v3) ½º´©ÇÎ(Snooping)
- SSL(Secure Sockets Layer)
- SNMPv3(Àбâ Àü¿ë)
°ü¸®(¸ð´ÏÅ͸µ Àü¿ë) - BRIDGE-MIB
- ENTITY-MIB
- ETHERNET-MIB
- IF MIB
- RFC1213-MIB (MIB II)
- RMON-MIB(Åë°è, È÷½ºÅ丮, °æº¸ ¹× À̺¥Æ® ±×·ì Àü¿ë)
- CISCO-PRODUCTS-MIB
- CISCO-SYSLOG-MIB
- CISCO-ENVMON-MIB
Ä¿³ØÅÍ ¹× ÄÉÀ̺í - 10/100BASE-TX Æ÷Æ®: RJ-45 Ä¿³ØÅÍ, 2-pair Category 5 UTP(Unshielded Twisted Pair) ÄÉÀ̺í
- 10/100/1000BASE-T Æ÷Æ®: RJ-45 Ä¿³ØÅÍ, 4-pair Category 5 UTP ÄÉÀ̺í
- 1000BASE-SX, 1000BASE-LX/LH, 100BASE-FX, 100BASE-LX ¹× 100BASE-BX-±â¹Ý Æ÷Æ®: LC ±¤¼¶À¯ Ä¿³ØÅÍ(´ÜÀϸðµå ¹× ´ÙÁ߸ðµå ±¤¼¶À¯)
¹°¸®Àû »ç¾ç ±Ô°Ý(H x W x D):
- Cisco Catalyst Express 500-24TT, Catalyst Express 500-24LC ¹× Catalyst Express 500G-12TC¿ëÀº 1.73 x 17.5 x 9.9 ÀÎÄ¡(4.39 x 44.45 x 25.15 cm)
- Cisco Catalyst Express 500-24PC¿ëÀº 1.73 x 17.5 x 14.4ÀÎÄ¡(4.39 x 44.45 x 36.58 cm)

Áß·®:
- Cisco Catalyst Express 500-24TT, Catalyst Express 500-24LC ¹× Catalyst Express 500G-12TC¿ëÀº 8lb(3.7kg)
- Cisco Catalyst Express 500-24PC¿ëÀº 12lb(5.5 kg)
Àü·Â ¿ä±¸»çÇ×
½ºÀ§Ä¡ ¸ðµ¨
Cisco Catalyst Express 500-24TT
Cisco Catalyst Express 500-24LC
Cisco Catalyst Express 500-24PC
Cisco Catalyst Express 500G-12TC
Àü·Â ¼Òºñ·®(ÃÖ´ë)
½Ã°£´ç 30W ¶Ç´Â 102 BTU
½Ã°£´ç 110W ¶Ç´Â 375 BTU
½Ã°£´ç 460W ¶Ç´Â 1570 BTU
½Ã°£´ç 45W ¶Ç´Â 154BTU
Àü·Â ¼Ò¸ð
30W
45W
90W
45W


ÀÔ·Â Àü¾Ð
- AC ÀÔ·Â Àü¾Ð/ÁÖÆļö 100-240Vac, 1.3-0.8A, 50-60Hz
- Cisco Redundant Power System 675¿ë DC ÀÔ·Â Àü¾Ð(Cisco Catalyst Express 500-24PC¸¸ Áö¿ø): 14A¿¡¼­ 12V, 7.8A¿¡¼­-48V
ȯ°æ ¿ä±¸»çÇ× ÀÛµ¿ ¿Âµµ: 32 ~ 113¡ÆF (0 ~ 45¡ÆC)
º¸°ü ¿Âµµ: - 13 ~ 158¡ÆF(- 25 ~ 70¡ÆC)
ÀÛµ¿ »ó´ë ½Àµµ: 10 ~ 85%(ºñÀÀ°á)
ÀÛµ¿ °íµµ: ÃÖ´ë 10,000 ÇÇÆ®(3049 m)
º¸°ü °íµµ: ÃÖ´ë 15,000 ÇÇÆ®(4573 m)
¿¹»ó MTBF(Mean Time Between Failure) Cisco Catalyst Express 500-24TT´Â 308,482½Ã°£ ¶Ç´Â 35³â
Cisco Catalyst Express 500-24LC´Â 282,705½Ã°£ ¶Ç´Â 32³â
Cisco Catalyst Express 500-24PC´Â 211,167½Ã°£ ¶Ç´Â 24³â
Cisco Catalyst Express 500G-12TC´Â 289,193½Ã°£ ¶Ç´Â 33³â
À½ÆÄ ¼ÒÀ½ ISO 7770, ¹ÙÀ̽ºÅÄ´õ Æ÷Áö¼Ç: ÁÖº¯ ¿Âµµ 30¡ÆC±îÁö µ¿ÀÛ
Cisco Catalyst Express 500-24TT, Catalyst Express 500-24LC, Catalyst Express 500G-12TC: 40dBa, Cisco Catalyst Express 500-24PC: 48dBa
±ÔÁ¤ ±â°ü ½ÂÀÎ
¾ÈÀü ÀÎÁõ - UL¿¡¼­ UL 60950-1
- CUL¿¡¼­ CAN/CSA C22.2 No. 60950-1
- TUV/GS¿¡¼­ EN 60950-1
- CB¿¡¼­ IEC 60950-1(¸ðµç ±¹°¡ ÆíÂ÷ Àû¿ë)
- NOM¿¡¼­ NOM-019-SCFI
- CE Marking
ÀüÀڱ⠹æÃâ
ÀÎÁõ
- FCC Part 15 Class A
- EN 55022 Class A (CISPR22)
- EN 55024 (CISPR24)
- VCCI Class A
- AS/NZS CISPR22 Class A
- MIC
- China EMC ¿ä±¸»çÇ×
- GOST
 
Åùè, È­¹°, Äü¼­ºñ½º µî ´Ù¾çÇÑ ¿î¼Û¹æ¹ýÀ» ÀÌ¿ëÇÏ¿© ¹è¼ÛÀÌ °¡´ÉÇÕ´Ï´Ù.

¿îÀÓºñ´Â ±¸¸ÅÀÚ ºÎ´ãÀÔ´Ï´Ù.
°¢ Á¦Á¶»çÀÇ A/S ±ÔÁ¤¿¡ µû¸¨´Ï´Ù.
¼ÒºñÀÚ º¸È£¹ý¿¡ µû¸¨´Ï´Ù.

¹®ÀÇ : 02-7989-114
 
 
 
 
 
À̸§ :
³»¿ë :
ÆòÁ¡
°í°´Æò°¡ : ÆòÁ¡ ¡Ú¡Ú¡Ú¡Ú¡Ú  
 
 
 
 
»óÇ°¿¡ ´ëÇØ ±Ã±ÝÇÑ Á¡À» ÇØ°áÇØ µå¸³´Ï´Ù.
¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ Á¶È¸
 
 
»óÇ°Èı⸦ ÀÛ¼ºÇØ ÁÖ¼¼¿ä.
 

Copyright ¨Ï ·£Àåºñ All Rights Reserved. TEL : 02-798-9114 , FAX : 02-716-7229
»óÈ£¸í : (ÁÖ)·£Àåºñ   »ç¾÷ÀÚµî·Ï¹øÈ£ : 106-86-16143 106-86-16143   Åë½ÅÆǸž÷½Å°í¹øÈ£ : Á¦ 2006-¼­¿ï¿ë»ê-00850È£   ´ëÇ¥ : ¾È±âÁß
[ÀÌ¿ë¾à°ü°³ÀÎÁ¤º¸Ãë±Þ¹æħ °³ÀÎÁ¤º¸´ã´çÀÚ : ¹Ú¿ë±¸ºÎÀå   »ç¾÷Àå¼ÒÀçÁö : ¼­¿ï ¿ë»ê±¸ ûÆÄ·Î 83, 4µ¿9¿­ 2,3È£(¿øÈ¿·Î3°¡,¿øÈ¿ÀüÀÚ»ó°¡)