º¸¾È Á¢¼Ó ·Î±×ÀÎ | ȸ¿ø°¡ÀÔ | Àå¹Ù±¸´Ï | °í°´¼¾ÅÍ
TEL : 02-798-9114
HPE-ARUBA[ÆÄ°Ý°¡]
CISCO [ƯÆǸðµ¨]
D-Link [Àü±¹ÃÖÀú°¡]
NETGEAR [ÃÖÀú°¡°ø±Þ]
Alcatel-Lucent Enterprise
½Ã½ºÄÚ Cisco
Cisco SB/Pro
ZyXEL
APC[ÀüÈ­¹®ÀÇ]
¼ÖÅØ(Soltech)
TP-LINK
¿¡ÀÌÅÙ[ATEN]
µðÆ÷±×(Defog)
DASAN(´Ù»ê)
UTM/VPN/¹æÈ­º®
ETK
¹«¼±·£/Wireless
¹«¼±°øÀ¯±â/¹«¼±AP/¾ÈÅ׳ª
À¯¼±Àåºñ/Network
½ºÀ§Ä¡/·£Ä«µå/ÇÁ¸°Åͼ­¹ö
POE ½ºÀ§Ä¡
10±â°¡ºñÆ® ÀÌ´õ³Ý
·£°ø±¸,CCTV ÀâÀÚÀç
FIBER Àåºñ/Á¡ÆÛÄÚµå
RACK/UPS/KVM
°¢Á¾ÄÉÀ̺í/Á¨´õ
¿µ»ó/À½Çâ/ºÐ¹è±â/°øÀ¯
½Ã¸®¾ó Åë½ÅÁ¦Ç°
¸ÖƼÆ÷Æ®/ÄÁ¹öÅÍ
»ê¾÷¿ë Á¦Ç°±º
CCTV ºñµð¿À¼­¹ö
USB/1394/ÁÖº¯±â±â
======================
AP
HIKVISION
INTEL
MOXA
Chesio (10G NIC)
IPTIME
Uniclass KVM
TYCO(AMP)
3COM
Britz
======================
°¡°ÝÁ¶Á¤
======================
802.11N
UBIQUITI
·£Àåºñ ¼Ò½Ä/¹®ÀÇ
°ø±Þ/±¸Ãà»ç·Ê
(ÁÖ)·£Àåºñ ÀÚ·á½Ç
 
ºñ¹Ð¹øÈ£ È®ÀÎ ´Ý±â
½Ã¸®¾ó Åë½ÅÁ¦Ç°
¸ÖƼÆ÷Æ®/ÄÁ¹öÅÍ

½Ã¸®¾ó Åë½ÅÁ¦Ç°
¸ÖƼÆ÷Æ®/ÄÁ¹öÅÍ
> 232/422/485 ->ÀÌ´õ³Ý > MOXA NPort5650-16 232/422/485 16Æ÷Æ® -> 10/100BASE-T
     
 ÀÌÀü»óÇ° MOXA NPort5650-16 232/422/485 16Æ÷Æ® -> 10/100BASE-T ´ÙÀ½»óÇ°
 
 
     
Á¦Á¶È¸»ç : MOXA
ÆǸŰ¡°Ý : °¡°Ý¹®ÀÇ
Àç°í È®ÀÎ ÈÄ ±¸ÀÔÇϼ¼¿ä
¼ö·® EA
 
 
 
 
 
 
 
 
 
»óÇ° »ó¼¼ ¼³¸í
 
 

Features and Benefits


  • 8 or 16 serial ports supporting RS-232/422/485
  • Standard 19-inch rackmount size
  • 10/100M auto-sensing Ethernet
  • Built-in 15 KV ESD protection for all serial signals
  • Easy IP address configuration with LCD panel
  • Choice of configuration methods: Web console, Telnet console, and Windows utility
  • Versatile socket operation modes, including TCP Server, TCP Client, UDP, and Real COM
  • SNMP MIB-II for network management

Overview

Network Readiness for up to Sixteen Serial Devices

The NPort¢ç 5650 rackmount device server can conveniently and transparently connect up to sixteen serial devices to an Ethernet, allowing you to network your existing serial devices with only basic configuration. Data transmission between the serial and Ethernet interfaces is bi-directional. By using NPort¢ç device servers, you not only protect your current hardware investment, but also allow for future network expansion. You can both centralize the management of your serial devices, and distribute management hosts over the network.

19-inch Rackmount Device Server

NPort¢ç 5600 device servers come with Tx/Rx LEDs for the serial ports on the front panel, and the 8 or 16 RJ45 serial port connectors on the rear panel. This makes the NPort¢ç 5600 device servers suitable for standard 19-inch rack mounting, allowing you to simplify operation, maintenance, and administrative tasks.

 

Real COM/TTY Ports

Real COM/TTY drivers are provided that make the serial ports on the NPort¢ç 5600 recognizable as Real COM ports by Windows, or Real TTY ports by Linux. In addition to supporting basic data transmission and reception, the NPort¢ç drivers also support the RTS, CTS, DTR, DSR, and DCD control signals.

 

LED Indicators to Ease Your Maintenance Tasks

The System LED, Serial Tx/Rx LEDs, and Ethernet LEDs (located on the RJ45 connector) provide a great tool for basic maintenance tasks and help engineers analyze problems in the field. The NPort¢ç 5600¡¯s LEDs not only indicate current system and network status, but also help field engineers monitor the status of attached serial devices.

 

Adjustable Termination and Pull High/Low Resistors

In some critical environments, termination resistors may be needed to prevent the reflection of serial signals. When using termination resistors, it is also important to set the pull high/low resistors correctly so that the electrical signal is not corrupted. Since no set of resistor values is universally compatible for all environments, the NPort¢ç 5600 has DIP switches on the bottom panel for setting the termination and pull high/low resistor values.

 

Appearance

 

 

Dimensions

 

 

Pin Assignment



LAN Interface
Number of Ports 1
Speed 10/100 Mbps
Connector(s) 8-pin RJ45
Magnetic Isolation Protection 1.5 KV built-in


• Optical Fiber Interface
Distance Multi mode: 0 to 2 km, 1310 nm (62.5/125 µm, 500 MHz*km)
Single mode: 0 to 40 km, 1310 nm (9/125 µm, 3.5 PS/(nm*km))
Min. TX Output -20 dBm (Multi mode), -5 dBm (Single mode)
Max. TX Output -14 dBm (Multi mode), 0 dBm (Single mode)
Sensitivity -34 to -30 dBm (Multi mode), -36 to -32 dBm (Single mode)


• Serial Interface
Serial Standards RS-232/422/485
Number of Ports 8 or 16
Connectors RJ45 (8 pins)
Serial Line Protection 15 KV ESD protection for all signals
RS-485 Data Direction Control ADDC¢ç (automatic data direction control)


• Serial Communication Parameters
Data Bits 5, 6, 7, 8
Stop Bits 1, 1.5, 2
Parity None, Even, Odd, Space, Mark
Flow Control DSR/DTR and RTS/CTS (RS-232 only), XON/XOFF
Baudrate 50 bps to 921.6 Kbps


• Serial Signals
RS-232 TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND
RS-422 Tx+, Tx-, Rx+, Rx-, GND
RS-485-4w Tx+, Tx-, Rx+, Rx-, GND
RS-485-2w Data+, Data-, GND


• Software
Network Protocols ICMP, IP, TCP, UDP, DHCP, BOOTP, Telnet, DNS, SNMP, HTTP, SMTP, SNTP, ARP, PPP, SLIP, RTelnet, RFC2217
Driver Support Windows Real COM driver (for Windows 95, 98, ME, NT, 2000, XP, 2003, Vista, XP x64, 2003 x64, Vista x64), Linux Real TTY driver, Fixed TTY driver (for SCO Unix, SCO OpenServer, UnixWare 7, UnixWare 2.1, SVR 4.2, QNX 4.25, QNX 6, Solaris 10, FreeBSD, AIX 5.x, HP-UX 11i)
Configuration Options Web Console, Telnet Console, Windows Utility


• Mini Screen with Push Buttons
LCD Panel Liquid Crystal Display on the case
Push Buttons Four push buttons for convenient on-site configuration


• Physical Characteristics
Enclosure SECC sheet metal (1 mm), providing IP30 protection
Weight NPort¢ç 5650-8: 3360 g
NPort¢ç 5650-8-S-SC: 3380 g
NPort¢ç 5650-8-M-SC: 3380 g
NPort¢ç 5650-16: 3460 g
NPort¢ç 5650-16-S-SC: 3440 g
NPort¢ç 5650-16-M-SC: 3440 g
Dimensions Without ears: 440 x 45 x 198 mm (17.32 x 1.77 x 7.80 in)
With ears: 480 x 45 x 198 mm (18.90 x 1.77 x 7.80 in)


• Environmental Limits
Operating Temperature 0 to 55¡ÆC (32 to 131¡ÆF)
Operating Humidity 5 to 95% RH
Storage Temperature -20 to 75¡ÆC (-4 to 167¡ÆF)


• Power Requirements
Input Voltage 100 to 240 VAC, 47 to 63 hz
Power Consumption NPort¢ç 5650-8/16: 158 mA @ 100 VAC, 102 mA @ 240 VAC
NPort¢ç 5650-8/16-S-SC: 164 mA @ 100 VAC, 110 mA @ 240 VAC
NPort¢ç 5650-8/16-M-SC: 174 mA @ 100 VAC, 113 mA @ 240 VAC
Power Line Protection 4 KV burst (EN61000-4-4: EFT/B), 2 KV surge (EN61000-4-5)


• Regulatory Approvals
Safety UL (UL60950-1), TÜV (EN60950-1)
EMC CE (EN55022 Class A, EN55024), FCC Part 15 Subpart B Class A
Medical EN60601-1-2 Class B, EN55011


• Reliability
Alert Tools Built-in buzzer and RTC (real-time clock)
Automatic Reboot Trigger Built-in WDT (watchdog timer)
MTBF (meantime between failures) NPort¢ç 5650-8: 117584 hrs
NPort¢ç 5650-16: 104767 hrs
NPort¢ç 5650-S-SC-8: 116914 hrs
NPort¢ç 5650-S-SC-16: 87528 hrs
NPort¢ç 5650-M-SC-8: 116914 hrs
NPort¢ç 5650-M-SC-16: 87528 hrs


• Warranty
Warranty Period 5 years
Details See www.moxa.com/warranty


External Device Servers

  Model No. Description

NPort 5650-8-S-SC

8-port RS-232/422/485 Serial Device Server, 10/100BaseF(X), Single Mode Fiber (SC Connector), 164 mA @ 100 VAC, 110 mA @ 240 VAC

NPort 5650-16-S-SC

16-port RS-232/422/485 Serial Device Server, 10/100BaseF(X), Single Mode Fiber (SC Connector), 164 mA @ 100 VAC, 110 mA @ 240 VAC

NPort 5650-8

8-port RS-232/422/485 to Ethernet Device Server, 158 mA @ 100 VAC, 102 mA @ 240 VAC

NPort 5650-16

16-port RS-232/422/485 to Ethernet Device Server, 158 mA @ 100 VAC, 102 mA @ 240 VAC

NPort 5650-8-M-SC

8-port RS-232/422/485 Serial Device Server, 10/100BaseF(X), Multi Mode Fiber (SC Connector), 174 mA @ 100 VAC, 113 mA @ 240 VAC

NPort 5650-16-M-SC

16-port RS-232/422/485 Serial Device Server, 10/100BaseF(X), Multi Mode Fiber (SC Connector), 174 mA @ 100 VAC, 113 mA @ 240 VAC

Connection Cables

  Model No. Description

CBL-RJ45M9-150

RJ45 (8-pin) to DB9(M) Cable

CBL-RJ45F9-150

RJ45 (8-pin) to DB9(F) Cable

CBL-RJ45M25-150

RJ45 (8-pin) to DB25(M) Cable

CBL-RJ45F25-150

8-pin RJ45 to DB25 female, 150 cm Connection Cable

 
Åùè, È­¹°, Äü¼­ºñ½º µî ´Ù¾çÇÑ ¿î¼Û¹æ¹ýÀ» ÀÌ¿ëÇÏ¿© ¹è¼ÛÀÌ °¡´ÉÇÕ´Ï´Ù.

¿îÀÓºñ´Â ±¸¸ÅÀÚ ºÎ´ãÀÔ´Ï´Ù.
°¢ Á¦Á¶»çÀÇ A/S ±ÔÁ¤¿¡ µû¸¨´Ï´Ù.
¼ÒºñÀÚ º¸È£¹ý¿¡ µû¸¨´Ï´Ù.

¹®ÀÇ : 02-7989-114
 
 
 
 
 
À̸§ :
³»¿ë :
ÆòÁ¡
°í°´Æò°¡ : ÆòÁ¡ ¡Ú¡Ú¡Ú¡Ú¡Ú  
 
 
 
 
»óÇ°¿¡ ´ëÇØ ±Ã±ÝÇÑ Á¡À» ÇØ°áÇØ µå¸³´Ï´Ù.
¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ Á¶È¸
 
 
»óÇ°Èı⸦ ÀÛ¼ºÇØ ÁÖ¼¼¿ä.
 

Copyright ¨Ï ·£Àåºñ All Rights Reserved. TEL : 02-798-9114 , FAX : 02-716-7229
»óÈ£¸í : (ÁÖ)·£Àåºñ   »ç¾÷ÀÚµî·Ï¹øÈ£ : 106-86-16143 [»ç¾÷ÀÚÁ¤º¸È®ÀÎ]   Åë½ÅÆǸž÷½Å°í¹øÈ£ : Á¦ 2006-¼­¿ï¿ë»ê-00850È£   ´ëÇ¥ : ¾È±âÁß
[ÀÌ¿ë¾à°ü°³ÀÎÁ¤º¸Ãë±Þ¹æħ °³ÀÎÁ¤º¸´ã´çÀÚ : ¹Ú¿ë±¸ºÎÀå   »ç¾÷Àå¼ÒÀçÁö : ¼­¿ï ¿ë»ê±¸ ûÆÄ·Î 83, 4µ¿9¿­ 2,3È£(¿øÈ¿·Î3°¡,¿øÈ¿ÀüÀÚ»ó°¡)