º¸¾È Á¢¼Ó ·Î±×ÀÎ | ȸ¿ø°¡ÀÔ | Àå¹Ù±¸´Ï | °í°´¼¾ÅÍ
TEL : 02-798-9114
HPE-ARUBA[ÆÄ°Ý°¡]
CISCO [ƯÆǸðµ¨]
D-Link [Àü±¹ÃÖÀú°¡]
NETGEAR [ÃÖÀú°¡°ø±Þ]
Alcatel-Lucent Enterprise
½Ã½ºÄÚ Cisco
Cisco SB/Pro
ZyXEL
APC[ÀüÈ­¹®ÀÇ]
¼ÖÅØ(Soltech)
TP-LINK
¿¡ÀÌÅÙ[ATEN]
µðÆ÷±×(Defog)
DASAN(´Ù»ê)
UTM/VPN/¹æÈ­º®
ETK
¹«¼±·£/Wireless
¹«¼±°øÀ¯±â/¹«¼±AP/¾ÈÅ׳ª
À¯¼±Àåºñ/Network
½ºÀ§Ä¡/·£Ä«µå/ÇÁ¸°Åͼ­¹ö
POE ½ºÀ§Ä¡
10±â°¡ºñÆ® ÀÌ´õ³Ý
·£°ø±¸,CCTV ÀâÀÚÀç
FIBER Àåºñ/Á¡ÆÛÄÚµå
RACK/UPS/KVM
°¢Á¾ÄÉÀ̺í/Á¨´õ
¿µ»ó/À½Çâ/ºÐ¹è±â/°øÀ¯
½Ã¸®¾ó Åë½ÅÁ¦Ç°
¸ÖƼÆ÷Æ®/ÄÁ¹öÅÍ
»ê¾÷¿ë Á¦Ç°±º
CCTV ºñµð¿À¼­¹ö
USB/1394/ÁÖº¯±â±â
======================
AP
HIKVISION
INTEL
MOXA
Chesio (10G NIC)
IPTIME
Uniclass KVM
TYCO(AMP)
3COM
Britz
======================
°¡°ÝÁ¶Á¤
======================
802.11N
UBIQUITI
·£Àåºñ ¼Ò½Ä/¹®ÀÇ
°ø±Þ/±¸Ãà»ç·Ê
(ÁÖ)·£Àåºñ ÀÚ·á½Ç
 
ºñ¹Ð¹øÈ£ È®ÀÎ ´Ý±â
HPE-ARUBA[ÆÄ°Ý°¡]
HPE-ARUBA[ÆÄ°Ý°¡] > Layer3 ½ºÀ§Ä¡ > 3800 ½ºÀ§Ä¡ > J9573A HPE-ARUBA 3800-24G-PoE+-2SFP+ ½ºÀ§Ä¡
     
 ÀÌÀü»óÇ° J9573A HPE-ARUBA 3800-24G-PoE+-2SFP+ ½ºÀ§Ä¡ ´ÙÀ½»óÇ°
 
 
     
Á¦Á¶È¸»ç : HPE-ARUBA
ÆǸŰ¡°Ý : 7,150,000¿ø
¼ö·® EA
 
 
 
 
 
 
 
 
 
»óÇ° »ó¼¼ ¼³¸í
 
 

ey selling points

¸Ç À§ ¸Ç À§
¼º´É, ź·Â¼º ¹× Ä·ÆÛ½º ¿¡Áö¿ë SDN Áö¿ø
HP 3800 ½ºÀ§Ä¡ ½Ã¸®Áî´Â ¼º´É, ź·Â¼º, À¯¿¬¼º°ú ¿£ÅÍÇÁ¶óÀÌÁî ¿¡Áö, SMB ¹× Áö»ç ¹èÄ¡¸¦ À§ÇÑ »ç¿ë ¿ëÀ̼ºÀ» Á¦°øÇÕ´Ï´Ù.
24 ¶Ç´Â 48±â°¡ºñÆ® ÀÌ´õ³Ý Æ÷Æ® ¹× Æí¸®ÇÑ ³»Àå 10GbE ¾÷¸µÅ©(10GBASE-T ¶Ç´Â SFP+), PoE+, ¿¡³ÊÁö È¿À²ÀûÀÎ ÀÌ´õ³Ý, ¹× ÇÖ ½º¿Ò °¡´ÉÇÑ ¿¹ºñ Àü¿ø °ø±Þ ÀåÄ¡¸¦ À¯¿¬ÇÏ°Ô ¹èÄ¡Çϱâ À§ÇÑ Àüü °èÃþ 3 ½ºÀ§Ä¡ ½Ã¸®ÁîÀÔ´Ï´Ù.
¸Þ½Ã ½ºÅÂÅ· ±â¼úÀÌ ¿É¼Ç ½ºÅÂÅ· ¸ðµâÀ» Æ÷ÇÔÇÏ´Â ½ºÅÂÅ· °¡´ÉÇÑ 1U Æû ÆÑÅÍ¿¡¼­ ¸ðµâ½Ä ¼¨½Ã¿Í °°Àº ź·Â¼ºÀ» Á¦°øÇÕ´Ï´Ù.
IPv4 BGP, Á¤Ã¥ ±â¹Ý ¶ó¿ìÆÃ, IPv4/IPv6 OSPF ¹× °­·ÂÇÑ QoS¸¦ Æ÷ÇÔÇÑ °í±Þ °èÃþ 2 ¹× 3 ±â´É ¼¼Æ®¸¦ °®Ãá ¶óÀ̼±½º°¡ ºÒÇÊ¿äÇÑ ¼ÒÇÁÆ®¿þ¾îÀÔ´Ï´Ù.
ÇâÈÄ ³×Æ®¿öÅ© º¸ÀåÀ» À§ÇØ OpenFlow 1.3 Áö¿øÀ» Æ÷ÇÔÇÏ´Â SDN(¼ÒÇÁÆ®¿þ¾î Á¤ÀÇ ³×Æ®¿öÅ©) Áö¿øÀ» Á¦°øÇÕ´Ï´Ù.
¸Þ½Ã ½ºÅÂÅ· ¹× ¿¡Áö¿¡¼­ Àü¿ø
HP 3800 ½ºÀ§Ä¡ ½Ã¸®Áî´Â °­·ÂÇÑ HP ³×Æ®¿öÅ· ASICÀ» ÀÌ¿ëÇÏ¿© ¸Å¿ì ÀûÀº ½Ã°£, °­È­µÈ ÆÐŶ ¹öÆÛ¸µ ¹× ÀûÀÀÇü Àü·Â »ç¿ëÀ» Á¦°øÇÕ´Ï´Ù.
¸Þ½Ã ½ºÅÂÅ· ±â¼úÀÌ ÃÖ´ë 336Gb/sÀÇ ½ºÅÂÅ· 󸮷® ¹× Áõ°¡µÈ ź·Â¼ºÀ» °¡Áø °í¼º´É ½ºÅÂÅ·À» Á¦°øÇÕ´Ï´Ù.
ÃÖ´ë 5°³ÀÇ 3800 ½ºÀ§Ä¡¸¦ ¸Þ½Ã ÅäÆú·ÎÁö¸¦ ½ºÅÃÇÒ ¼ö ÀÖÀ¸¸ç, Ãß°¡·Î 5°³¸¦ ¸µ¿¡ Á¤·ÄÇÒ ¼ö ÀÖ½À´Ï´Ù.
¼±Åà °¡´ÉÇÑ ´ë±â¿­ ±¸¼ºÀ¸·Î ³×Æ®¿öÅ© ¾ÖÇø®ÄÉÀ̼ÇÀÇ ¿ä±¸»çÇ׿¡ °¡Àå ÀûÇÕÇÑ ´ë±â¿­ ¹× ¿¬°áµÈ ¸Þ¸ð¸® ¹öÆÛ¸µ ¼ö¸¦ ¼±ÅÃÇÏ¿© ¼º´ÉÀ» Çâ»óÇÒ ¼ö ÀÖ½À´Ï´Ù.
º¹¿ø·Â ¹× °í°¡¿ë¼º
HP 3800 ½ºÀ§Ä¡ ½Ã¸®Áî´Â µ¿ÀûÀ¸·Î ¼­·Î ¹é¾÷ÇÏ´Â 2°³ÀÇ ¶ó¿ìÅÍ ±×·ìÀÌ IPv4 ¹× IPv6 ³×Æ®¿öÅ©¿¡¼­ ¸Å¿ì °¡¿ë¼ºÀÌ ³ôÀº ¶ó¿ìÅÍ È¯°æÀ» »ý¼ºÇÒ ¼ö ÀÖµµ·Ï °¡»ó ¶ó¿ìÅÍ ÀÌÁßÈ­ ÇÁ·ÎÅäÄÝ(VRRP)¸¦ Áö¿øÇÕ´Ï´Ù.
ÅëÇÕ Ä¿¹Â´ÏÄÉÀÌ¼Ç ¹× Çâ»óµÈ L3 °í°¡¿ë¼º°ú °°Àº °³¼±µÈ ¾ÖÇø®ÄÉÀÌ¼Ç Áö¿øÀ» À§ÇÑ ¹«Áß´Ü ½ºÀ§Äª ¹× ¶ó¿ìÆÃ.
ÀÌÁß ÇÖ ½º¿Ò °¡´É Àü¿ø °ø±Þ ÀåÄ¡´Â Áß´Ü ¾øÀÌ Àü¿øÀ» °ø±ÞÇÏ¿© ³×Æ®¿öÅ© °¡¿ë¼º¿¡ ¹ÌÄ¡´Â ¿µÇâÀ» ÁÙÀÌ°í Áï½Ã ¸ðµâ ½º¿ÒÀÌ °¡´ÉÇϵµ·Ï ÇÕ´Ï´Ù. ÃÖ´ë 1080W PoE+ Àü¿øÀ» Á¦°øÇÕ´Ï´Ù.
°­·ÂÇÑ º¸¾È ¹× ¼­ºñ½º Ç°Áú(QoS)
HP 3800 ½ºÀ§Ä¡ ½Ã¸®Áî¿¡´Â ²÷ÀÓ¾øÀÌ º¯È­ÇÏ´Â ±â¾÷ Á¤Ã¥ ¹× Áؼö¸¦ ÃæÁ·Çϵµ·Ï ³×Æ®¿öÅ©¸¦ ±¸ÃàÇϱâ À§ÇÏ¿© °­·ÂÇÑ º¸¾È ¹× QoS ±â´ÉÀÌ Æ÷ÇԵ˴ϴÙ.
À¯¿¬ÇÑ ÀÎÁõ ¿É¼ÇÀº ¿ì¼öÇÑ Á¤Ã¥ Áß½ÉÀÇ ¾ÖÇø®ÄÉÀÌ¼Ç º¸¾ÈÀ» À§ÇÑ ·ÎÄà MAC, 802.1X, MAC ¹× À¥ ¸ðµ¨À» Æ÷ÇÔÇÕ´Ï´Ù.
DHCP ½º´©ÇÎ, IP ¼Ò½º º¸È£ ¹× ARP º¸È£¿Í °°Àº °í±Þ ºÐ»êµÈ ¼­ºñ½º °ÅºÎ(DDOS) º¸È£ ¹× ARP º¸È£-À¯¿¬ÇÑ Æ®·¡ÇÈ Á¦¾î ÇÁ·Î±×·¥, Á¤Ã¥ ±â¹Ý ¶ó¿ìÆÃ, QoS, ACL´Â ¿£µå-Åõ-¿£µå(end-to-end) ¾ÖÇø®ÄÉÀÌ¼Ç ¿ì¼±¼øÀ§¸¦ °ü¸®ÇÕ´Ï´Ù.
´Ù¾çÇÑ º¸¾È °ü¸® ·Î±×ÀÎ, RADIUS/TACACS+, SSH¿Í °°Àº °­·ÂÇÑ ´Ù´Ü°è ¾×¼¼½º º¸¾È Á¦¾î´Â º¸¾ÈÀ» Çâ»óÇÏ°í º¯°æ °ü¸® ¾×¼¼½º¸¦ Á¦¾îÇÕ´Ï´Ù.
HP 3800 ½ºÀ§Ä¡ ½Ã¸®Áî´Â HP IMC(Intelligent Management Center) ¼ÒÇÁÆ®¿þ¾î¸¦ ÅëÇØ ¿øÈ°ÇÏ°Ô °ü¸®ÇÒ ¼ö ÀÖ¾î Æ÷°ýÀûÀÎ ±¸¼º, Áؼö ¹× Á¤Ã¥ °ü¸®¸¦ ÅëÇØ ¿£µå-Åõ-¿£µå(end-to-end) ³×Æ®¿öÅ© Åõ¸í¼º¿¡ ÀÏ°üµÈ ³×Æ®¿öÅ© »ç¿ë ȯ°æÀ» Á¦°øÇÕ´Ï´Ù.
¼º´É
Å¥ ±¸¼º ¼±Åà °¡´É: ³×Æ®¿öÅ© ÀÀ¿ë ÇÁ·Î±×·¥ÀÇ ¿ä±¸»çÇ׿¡ °¡Àå ÀûÇÕÇÑ ´ë±â¿­ ¹× ¿¬°áµÈ ¸Þ¸ð¸® ¹öÆÛ¸µ ¼ö¸¦ ¼±ÅÃÇÏ¿© ¼º´ÉÀ» Çâ»óÇÒ ¼ö ÀÖ½À´Ï´Ù.
¿¡³ÊÁö È¿À² ¼³°è: °íÈ¿À² Àü¿ø °ø±ÞÀåÄ¡: 80°³ÀÇ PLUS GOLD ÀÎÁõ Àü¿ø °ø±ÞÀåÄ¡°¡ ÀýÀü ±â´ÉÀ» Çâ»ó½Ãŵ´Ï´Ù. ¿¡³ÊÁö È¿À² ÀÌ´õ³Ý Áö¿ø: IEEE 802.3az Áö¿øÀ» ÅëÇØ Àü·Â »ç¿ëÀÌ °¨¼ÒµË´Ï´Ù.
¸Þ½ÃÇü ½ºÅÂÅ· ±â¼ú: °í¼º´É ½ºÅÂÅ·: ÃÖ´ë 336GB/sÀÇ ½ºÅÂÅ· 󸮷®À» Á¦°øÇÕ´Ï´Ù. °¢°¢ÀÇ 4Æ÷Æ® ½ºÅÂÅ· ¸ðµâÀº ½ºÅÂÅ· Æ÷Æ®´ç °¢ ¹æÇâÀ¸·Î ÃÖ´ë 42GB/s¸¦ Áö¿øÇÒ ¼ö ÀÖ½À´Ï´Ù. ¸µ, üÀÎ ¹× ¸Þ½Ã ÅäÆú·ÎÁö: ÃÖ´ë 10 ±¸¼º¿ø ¸µ ¶Ç´Â üÀΰú 5 ±¸¼º¿ø ¿ÏÀü ¸Þ½ÃÇü ½ºÅÃÀ» Áö¿øÇÕ´Ï´Ù. ¸Þ½ÃÇü ÅäÆú·ÎÁö´Â Ç¥ÁØ ¸µ¿¡ ºñÇØ ´õ ³ôÀº ź·Â¼ºÀ» Á¦°øÇÕ´Ï´Ù. °¡»óÈ­µÈ Àüȯ: ½ºÅÂÅ·ÀÌ µÇ¸é ½ºÀ§Ä¡°¡ ´ÜÀÏ ¼¨½Ã·Î Ç¥½ÃµÇ¾î °£ÆíÇÏ°Ô °ü¸®ÇÒ ¼ö ÀÖ½À´Ï´Ù.
HP ProVision ASIC ±¸Á¶: ´ë±â½Ã°£ÀÌ ¸Å¿ì ÀûÀ¸¸ç, ÆÐŶ ¹öÆÛ¸µ, ÀûÀÀÇü Àü·Â »ç¿ëÀ» °®Ãá ÃֽŠHP ProVision ASIC·Î ¼³°èµÊ
º¹¿ø·Â°ú °í°¡¿ë¼º
Nonstop ½ºÀ§Äª ¹× ¶ó¿ìÆÃ: ÅëÇÕ Ä¿¹Â´ÏÄÉÀÌ¼Ç ¹× À̵¿¼º °°Àº Áß¿ä ÀÀ¿ë ÇÁ·Î±×·¥À» ´õ Àß Áö¿øÇϱâ À§ÇØ ³×Æ®¿öÅ© °¡¿ë¼ºÀ» °³¼±ÇÕ´Ï´Ù. ¹é¾÷ ±¸¼º¿øÀÌ Commander°¡ µÉ °æ¿ì Àå¾Ö Á¶Ä¡ Áß¿¡µµ Æ®·¡ÇÈÀÌ Áö¼ÓÀûÀ¸·Î Àü´ÞµÉ °ÍÀÔ´Ï´Ù.
IEEE 802.3ad ¸µÅ© ÅëÇÕ Á¦¾î ÇÁ·ÎÅäÄÝ(LACP) ¹× HP Æ÷Æ® Æ®··Å·: Æ®··Å©´ç ÃÖ´ë 8°³ ¸µÅ©(Æ÷Æ®)¾¿ ÃÖ´ë 24°³ Æ®··Å© Áö¿ø
IEEE 802.1s ´ÙÁß ½ºÆÐ´× Æ®¸®: ´ÙÁß ½ºÆÐ´× Æ®¸®¸¦ Çã¿ëÇÏ¿© ´ÙÁß VLAN ȯ°æ¿¡¼­ ³ôÀº ¸µÅ© °¡¿ë¼º Á¦°ø; IEEE 802.1d ¹× IEEE 802.1w¿¡ ´ëÇÑ ·¹°Å½Ã Áö¿ø Á¦°ø
°¡»ó ¶ó¿ìÅÍ Àå¾Öº¹±¸ ÇÁ·ÎÅäÄÝ(VRRP): °í°¡¿ë¼º ¶ó¿ìÆà ȯ°æÀ» Á¦°øÇϱâ À§ÇÏ¿© ±×·ì ³» 2°³ÀÇ ¶ó¿ìÅÍ°¡ µ¿ÀûÀ¸·Î ¼­·Î¸¦ ¹é¾÷
µà¾ó ÇÖ ½º¿Ò °¡´É Àü¿ø °ø±ÞÀåÄ¡: º¹¿ø¼º Áõ°¡: µÎ ¹ø° Àü¿ø °ø±ÞÀåÄ¡¸¦ »ç¿ëÇÏ¿© Àü¼± ¶Ç´Â Àü¿ø °ø±ÞÀåÄ¡ Àå¾Ö°¡ ¹ß»ýÇÒ °æ¿ì ½ºÀ§Ä¡ Àü¿øÀ» ¿ÏÀüÈ÷ º¹±¸ÇÒ ¼ö ÀÖ½À´Ï´Ù. PoE+ Àü·Â Áõ°¡: µÎ ¹ø° Àü¿ø °ø±ÞÀåÄ¡´Â »ç¿ë °¡´ÉÇÑ ÃÑ PoE+ Àü·ÂÀ» Áõ°¡½Ãų ¼ö ÀÖ½À´Ï´Ù.
°èÃþ 2 Àüȯ
GARP VLAN µî·Ï ÇÁ·ÎÅäÄÝ: VLANÀÇ µ¿Àû ÁöÁ¤ ¹× ÀÚµ¿ ÇнÀ °¡´É
IEEE 802.1ad QinQ: °èÃþ ±¸Á¶¸¦ Á¦°øÇÔÀ¸·Î½á ÀÌ´õ³Ý ³×Æ®¿öÅ©ÀÇ È®À强 Áõ´ë; °í¼Ó Ä·ÆÛ½º ¶Ç´Â ´ëµµ½Ã ³×Æ®¿öÅ©¿¡¼­ ´ÙÁß LAN ¿¬°á
VLAN Áö¿ø ¹× űë: IEEE 802.1Q Ç¥ÁØ°ú 2,048 VLANÀ» µ¿½Ã Áö¿ø
IEEE 802.1v ÇÁ·ÎÅäÄÝ VLANs: ÀÚü VLANÀ¸·Î ÀϺΠºñ-IPv4 ÇÁÅäÅäÄÝÀ» ÀÚµ¿À¸·Î ºÐ¸®
MAC ±â¹Ý VLAN: ¼¼ºÎÀûÀÎ Á¦¾î ¹× º¸¾ÈÀ» Á¦°øÇϸç RADIUS¸¦ »ç¿ëÇÏ¿© MAC ÁÖ¼Ò/»ç¿ëÀÚ¸¦ ƯÁ¤ VLAN¿¡ ¸ÅÇÎÇÒ ¼ö ÀÖ½À´Ï´Ù.

»óÀÚ ³»¿ë¹°

¸Ç À§ ¸Ç À§
(1)HP 3800-24G-PoE+-2SFP+ ½ºÀ§Ä¡


±â¼ú »ç¾ç

¿¬°á
ÀûÀç ±â´É °¡»ó; ½ºÀ§Ä¡ 10°³
³×Æ®¿öÅ·
BGP RFC 1997 BGP Ä¿¹Â´ÏƼ ¼Ó¼º, RFC 2918 °æ·Î »õ·Î °íħ ±â´É, RFC 4271 A °æ°è¼± °ÔÀÌÆ®¿þÀÌ ÇÁ·ÎÅäÄÝ 4(BGP-4); RFC 4456 BGP °æ·Î ¸®Ç÷º¼Ç: Ç® ¸Þ½Ã ³»ºÎ BGP(IBGP)ÀÇ ´ë¾È, RFC 4724 BGP Á¤»ó Àç½ÃÀÛ ¸ÞÄ¿´ÏÁò; RFC 5492 BGP-4 ±â´É ±¤°í
º¸¾È IEEE 802.1X Æ÷Æ® ±â¹Ý ³×Æ®¿öÅ© ¾×¼¼½º Á¦¾î, RFC 1492 TACACS+; RFC 2865 RADIUS(Ŭ¶óÀ̾ðÆ®¸¸); RFC 2866 RADIUS °ú±Ý, RFC 3579 EAP(Extensible Authentication Protocol)¿¡ ´ëÇÑ RADIUS Áö¿ø; SSL(Secure Sockets Layer); SSHv2 º¸¾È ¼Ð
³×Æ®¿öÅ© °ü¸® IEEE 802.1AB ¸µÅ© °èÃþ Ž»ö ÇÁ·ÎÅäÄÝ(LLDP); RFC 2819 RMON 4 ±×·ì: 1(Åë°è), 2(±â·Ï), 3(°æº¸) ¹× 9(À̺¥Æ®); RFC 3176 sFlow; ANSI/TIA-1057 LLDP ¹Ìµð¾î ¿£µåÆ÷ÀÎÆ® °Ë»ö(LLDP-MED); SNMPv1/v2c/v3; XRMON
IP Multicast RFC 3376 IGMPv3(È£½ºÆ® Á¶Àθ¸), RFC 3973 PIM µ§½º ¸ðµå, RFC 4601 PIM ½ºÆĽº ¸ðµå(Sparse Mode)
IPv6 RFC 1981 IPv6 °æ·Î MTU °Ë»ö, RFC 2375 IPv6 ¸ÖƼij½ºÆ® ÁÖ¼Ò ÇÒ´ç, RFC 2460 IPv6 »ç¾ç, RFC 2464 ÀÌ´õ³Ý ³×Æ®¿öÅ©¸¦ ÅëÇÑ IPv6 Àü¼Û, RFC 2710 IPv6¿ë MLD(¸ÖƼij½ºÆ® ¼ö½Å±â °Ë»ö), RFC 2925 ¿ø°Ý Ping, Traceroute ¹× Á¶È¸ ÀÛ¾÷¿ë °ü¸® ´ë»ó ¿ÀºêÁ§Æ® Á¤ÀÇ(Ping¸¸), RFC 3019 MLDv1 MIB, RFC 3315 DHCPv6(Ŭ¶óÀ̾ðÆ®¸¸), RFC 3484 IPv6¿ë ±âº» ÁÖ¼Ò ¼±ÅÃ, RFC 3587 IPv6 ±Û·Î¹ú À¯´Ïij½ºÆ® ÁÖ¼Ò Çü½Ä, RFC 3596 IPv6¿ë DNS È®Àå, RFC 3810 MLDv2(È£½ºÆ® Á¶Àθ¸), RFC 4022 TCP¿ë MIB, RFC 4087 IP ÅͳΠMIB, RFC 4113 UDP¿ë MIB, RFC 4213 IPv6 È£½ºÆ® ¹× ¶ó¿ìÅÍÀÇ ±âº» Àüȯ ¸ÞÄ¿´ÏÁò, RFC 4251 SSHv6 ¾ÆÅ°ÅØó, RFC 4252 SSHv6 ÀÎÁõ, RFC 4253 SSHv6 Àü¼Û °èÃþ, RFC 4254 SSHv6 ¿¬°á, RFC 4291 IP ¹öÀü 6 ÁÖ¼Ò ÁöÁ¤ ¾ÆÅ°ÅØó, RFC 4293 IP¿ë MIB, RFC 4294 IPv6 ³ëµå ¿ä±¸ »çÇ×, RFC 4419 SSH¿ë Å° ±³È¯, RFC 4443 ICMPv6, RFC 4541 IGMP ¹× MLD ½º´©ÇÎ ½ºÀ§Ä¡, RFC 4861 IPv6 ÀÎÁ¢ °Ë»ö, RFC 4862 IPv6 »óÅ ¾ø´Â ÁÖ¼Ò ÀÚµ¿ ±¸¼º, RFC 5095 IPv6¿¡¼­ À¯Çü 0 ¶ó¿ìÆà Çì´õÀÇ »ç¿ë Áß´Ü, RFC 5340 IPv6¿ë OSPFv3, RFC 5453 ¿¹¾àµÈ IPv6 ÀÎÅÍÆäÀ̽º ½Äº°ÀÚ, RFC 5519 ¸ÖƼij½ºÆ® ±×·ì ¸â¹ö½Ê °Ë»ö MIB(MLDv2¸¸), RFC 5722 °ãÄ¡´Â IPv6 Á¶°¢ ó¸®
¼­ºñ½º º¸È£ °ÅºÎ CPU DoS º¸È£
QoS/Cos RFC 2474 DiffServ ¿ì¼± ¼øÀ§, Æ÷Æ® ´ç 8 ´ë±â¿­ Æ÷ÇÔ; RFC 2597 DiffServ AF(Assured Forwarding); RFC 2598 DiffServ EF(Expedited Forwarding)
°ü¸® Æ¯Â¡ IMC(Áö´ÉÇü °ü¸® ¼¾ÅÍ); ¸í·ÉÁÙ ÀÎÅÍÆäÀ̽º; À¥ ºê¶ó¿ìÀú; ±¸¼º ¸Þ´º
ÀåÄ¡ °ü¸®ÀÚ RFC 1591 DNS(Ŭ¶óÀ̾ðÆ®); HTML ¹× ÅÚ³Ý °ü¸®
OSPF RFC 2328 OSPFv2, RFC 3101 OSPF NSSA, RFC 3623 Á¤»ó OSPF Àç½ÃÀÛ(°èȹÇÏÁö ¾ÊÀº °³ÀÔÀÌ ÀÖÀ» °æ¿ì¿¡¸¸); RFC 5340 IPv6¿ë OSPFv3
MIB IEEE 802.1ap(MSTP ¹× STP MIB¸¸), RFC 1213 MIB II, RFC 1493 ºê¸®Áö MIB, RFC 1724 RIPv2 MIB, RFC 1850 OSPFv2 MIB, RFC 2021 RMONv2 MIB, RFC 2096 IP Àü´Þ Å×À̺í MIB, RFC 2613 SMON MIB, RFC 2618 RADIUS Ŭ¶óÀ̾ðÆ® MIB, RFC 2620 RADIUS °ú±Ý MIB, RFC 2665 Ethernet-Like-MIB, RFC 2668 802.3 MAU MIB, RFC 2674 802.1p ¹× IEEE 802.1Q ºê¸®Áö MIB, RFC 2737 ¿£ÅÍƼ MIB(¹öÀü 2), RFC 2787 VRRP MIB, RFC 2863 ÀÎÅÍÆäÀ̽º ±×·ì MIB, RFC 2925 Ping MIB, RFC 2933 IGMP MIB
¸Þ¸ð¸® ¹× ÇÁ·Î¼¼¼­ HP ProVision ASIC/ARM @ 350MHz; Freescale P2020 @ 1200MHz; 4GB Ç÷¡½Ã; ÆÐŶ ¹öÆÛ Å©±â: 18MB µ¿Àû; 2GB SDRAM
ÀϹݠÇÁ·ÎÅäÄÝ IEEE 802.1ad Q-in-Q; IEEE 802.1AX-2008 ¸µÅ© ÅëÇÕ; IEEE 802.1D MAC ºê¸´Áö; IEEE 802.1p ¿ì¼±±Ç; IEEE 802.1Q VLANs; IEEE 802.1s ´ÙÁß ½ºÆÐ´× Æ®¸®; IEEE 802.1v VLAN ÇÁ·ÎÅäÄÝ ¹× Æ÷Æ® ±âÁØ ºÐ·ù; IEEE 802.1w ½ºÆÐ´× Æ®¸®ÀÇ ½Å¼ÓÇÑ À籸¼º; IEEE 802.3ad ¸µÅ© ÅëÇÕ Á¦¾î ÇÁ·ÎÅäÄÝ(LACP); IEEE 802.3af PoE(Power over Ethernet); IEEE 802.3x È帧 Á¦¾î; RFC 768 UDP; RFC 783 TFTP ÇÁ·ÎÅäÄÝ(°³Á¤ 2); RFC 792 ICMP; RFC 793 TCP; RFC 826 ARP; RFC 854 TELNET; RFC 868 ½Ã°£ ÇÁ·ÎÅäÄÝ; RFC 951 BOOTP; RFC 1058 RIPv1; RFC 1350 TFTP ÇÁ·ÎÅäÄÝ(°³Á¤ 2); RFC 1519 CIDR; RFC 1542 BOOTP È®Àå; RFC 2030 SNTP(Simple Network Time Protocol) v4; RFC 2131 DHCP; RFC 2453 RIPv2; RFC 2548(MS-RAS-Vendor¸¸ ÇØ´ç); RFC 3046 DHCP ¸±·¹ÀÌ ¿¡ÀÌÀüÆ® Á¤º¸ ¿É¼Ç; RFC 3576 RADIUS È®Àå(CoA¸¸); RFC 3768 VRRP; RFC 4675 RADIUS VLAN ¹× ¿ì¼±±Ç; ´Ü¹æÇâ ¸µÅ© °¨Áö(UDLD)
¼º´É
½ºÀ§Äª ±â´É 88Gbps
󸮷® ÃÖ´ë 65.4Mpps
Æ÷Æ®
Æ÷Æ® 24°³ÀÇ RJ-45 ÀÚµ¿ °¨Áö 10/100/1000 PoE+ Æ÷Æ®; 2°³ÀÇ °íÁ¤ 1000/10000 SFP+ Æ÷Æ®; ±¸¼ºÇ°
Àü·Â
Àü·Â °ø±ÞÀåÄ¡ À̸§ 1 x J9580A
Àü·Â °ø±ÞÀåÄ¡ PoE 720 W PoE+
¼Òºñ Àü·Â ÃÖ´ë 127W
ÀԷ Àü¾Ð 100~120/200~240VAC
ÀԷ ¿î¿µ Àü·ù 9.4/7.8A
Àü¿ø ´ÜÀÏ 120V ÀÔ·Â Àü¿ø °ø±ÞÀåÄ¡ »ç¿ë ½Ã, ÃÖ´ë 572W PoE Àü·ÂÀ» »ç¿ëÇÒ ¼ö ÀÖ½À´Ï´Ù.

ȣȯ¼º Á¤º¸

¸Ç À§ ¸Ç À§
Ç¥ÁØ
ÀüÀÚ±âÆĠȣȯ¼º FCC Class A; VCCI Class A; EN 55022/CISPR 22 Class A
¸éÃ¥ Ç¥ÁØ EN 55024, CISPR 24; IEC 61000-4-2; IEC 61000-4-3; 3 V/m; IEC 61000-4-4; 1.0kV(Àü·Â¼±), 0.5kV(½ÅÈ£ ¶óÀÎ); IEC 61000-4-5; 1kV/2kV AC; IEC 61000-4-6; 3V; IEC 61000-4-8; 1A/m, 50 ¶Ç´Â 60Hz; IEC 61000-4-11; > 95% °¨¼Ò, 0.5 ÁÖ±â; 30% °¨¼Ò, 25 ÁÖ±â; EN 61000-3-2, IEC 61000-3-2; EN 61000-3-3, IEC 61000-3-3

ȯ°æ Á¤º¸

¸Ç À§ ¸Ç À§
À½Ç⠾з ¹æÃâ
À½¾Ð ¹æÃâ Àü¿ø: 49dB, ¾Ð·Â: 33.7dB
¹æ¿­
¿­ ¼Õ½Ç 434BTU/½Ã°£(457.87kJ/½Ã°£)
±âŸ
ECO Äü ¸µÅ© ±âÈ£ 02 URL http://h71028.www7.hp.com/enterprise/us/en/solutions/hp-carbon-footprint-calculator.html?jumpid=re_r138_eco_home_carbon_footprint_learn_more
ECO Äü ¸µÅ© ±âÈ£ 01 URL http://www.hp.com/hpinfo/globalcitizenship/environment/recycling/unwanted-hardware.html
ECO Äü ¸µÅ© ±âÈ£ 01 URL ±¸¹® ÀçÈ°¿ë ¹× Àç»ç¿ë ¿É¼Ç
ECO Äü ¸µÅ© ±âÈ£ 02 URL ±¸¹® ź¼Ò ¹èÃâ·® °è»ê±â
ECO Äü ¸µÅ© ±âÈ£ 03 URL ±¸¹® HP¿Í ȯ°æ
ECO Äü ¸µÅ© ±âÈ£ 03 URL http://hp.com/environment
¿Âµµ
ÀÛµ¿ ¿Âµµ 0~55¡É

¹°¸®Àû Å©±â

¸Ç À§ ¸Ç À§
Weights
¹«°Ô 7.21kg
 
Åùè, È­¹°, Äü¼­ºñ½º µî ´Ù¾çÇÑ ¿î¼Û¹æ¹ýÀ» ÀÌ¿ëÇÏ¿© ¹è¼ÛÀÌ °¡´ÉÇÕ´Ï´Ù.

¿îÀÓºñ´Â ±¸¸ÅÀÚ ºÎ´ãÀÔ´Ï´Ù.
°¢ Á¦Á¶»çÀÇ A/S ±ÔÁ¤¿¡ µû¸¨´Ï´Ù.
¼ÒºñÀÚ º¸È£¹ý¿¡ µû¸¨´Ï´Ù.

¹®ÀÇ : 02-7989-114
 
 
 
 
 
À̸§ :
³»¿ë :
ÆòÁ¡
°í°´Æò°¡ : ÆòÁ¡ ¡Ú¡Ú¡Ú¡Ú¡Ú  
 
 
 
 
»óÇ°¿¡ ´ëÇØ ±Ã±ÝÇÑ Á¡À» ÇØ°áÇØ µå¸³´Ï´Ù.
¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ Á¶È¸
 
 
»óÇ°Èı⸦ ÀÛ¼ºÇØ ÁÖ¼¼¿ä.
 

Copyright ¨Ï ·£Àåºñ All Rights Reserved. TEL : 02-798-9114 , FAX : 02-716-7229
»óÈ£¸í : (ÁÖ)·£Àåºñ   »ç¾÷ÀÚµî·Ï¹øÈ£ : 106-86-16143 106-86-16143   Åë½ÅÆǸž÷½Å°í¹øÈ£ : Á¦ 2006-¼­¿ï¿ë»ê-00850È£   ´ëÇ¥ : ¾È±âÁß
[ÀÌ¿ë¾à°ü°³ÀÎÁ¤º¸Ãë±Þ¹æħ °³ÀÎÁ¤º¸´ã´çÀÚ : ¹Ú¿ë±¸ºÎÀå   »ç¾÷Àå¼ÒÀçÁö : ¼­¿ï ¿ë»ê±¸ ûÆÄ·Î 83, 4µ¿9¿­ 2,3È£(¿øÈ¿·Î3°¡,¿øÈ¿ÀüÀÚ»ó°¡)