º¸¾È Á¢¼Ó ·Î±×ÀÎ | ȸ¿ø°¡ÀÔ | Àå¹Ù±¸´Ï | °í°´¼¾ÅÍ
TEL : 02-798-9114
HPE-ARUBA[ÆÄ°Ý°¡]
CISCO [ƯÆǸðµ¨]
D-Link [Àü±¹ÃÖÀú°¡]
NETGEAR [ÃÖÀú°¡°ø±Þ]
Alcatel-Lucent Enterprise
½Ã½ºÄÚ Cisco
Cisco SB/Pro
ZyXEL
APC[ÀüÈ­¹®ÀÇ]
¼ÖÅØ(Soltech)
TP-LINK
¿¡ÀÌÅÙ[ATEN]
µðÆ÷±×(Defog)
DASAN(´Ù»ê)
UTM/VPN/¹æÈ­º®
ETK
¹«¼±·£/Wireless
¹«¼±°øÀ¯±â/¹«¼±AP/¾ÈÅ׳ª
À¯¼±Àåºñ/Network
½ºÀ§Ä¡/·£Ä«µå/ÇÁ¸°Åͼ­¹ö
POE ½ºÀ§Ä¡
10±â°¡ºñÆ® ÀÌ´õ³Ý
·£°ø±¸,CCTV ÀâÀÚÀç
FIBER Àåºñ/Á¡ÆÛÄÚµå
RACK/UPS/KVM
°¢Á¾ÄÉÀ̺í/Á¨´õ
¿µ»ó/À½Çâ/ºÐ¹è±â/°øÀ¯
½Ã¸®¾ó Åë½ÅÁ¦Ç°
¸ÖƼÆ÷Æ®/ÄÁ¹öÅÍ
»ê¾÷¿ë Á¦Ç°±º
CCTV ºñµð¿À¼­¹ö
USB/1394/ÁÖº¯±â±â
======================
AP
HIKVISION
INTEL
MOXA
Chesio (10G NIC)
IPTIME
Uniclass KVM
TYCO(AMP)
3COM
Britz
======================
°¡°ÝÁ¶Á¤
======================
802.11N
UBIQUITI
·£Àåºñ ¼Ò½Ä/¹®ÀÇ
°ø±Þ/±¸Ãà»ç·Ê
(ÁÖ)·£Àåºñ ÀÚ·á½Ç
 
ºñ¹Ð¹øÈ£ È®ÀÎ ´Ý±â
NETGEAR [ÃÖÀú°¡°ø±Þ]
NETGEAR [ÃÖÀú°¡°ø±Þ] > ±â°¡ºñÆ® ½ºÀ§Ä¡ > ½ºÅÂÅ· ½ºÀ§Ä¡ > ³Ý±â¾î GS728TXS, 24Æ÷Æ® 10/100/1000Base-T + 4Æ÷Æ® 10G SFP+
     
 ÀÌÀü»óÇ° ³Ý±â¾î GS728TXS, 24Æ÷Æ® 10/100/1000Base-T + 4Æ÷Æ® 10G SFP+ ´ÙÀ½»óÇ°
 
 
     
ÆǸŰ¡°Ý : GS728TX·Î ´ëü
¼ö·® EA
 
 
 
 
 
 
 
 
 
»óÇ° »ó¼¼ ¼³¸í
 
 

±Þ¼Óµµ·Î Áõ°¡ÇÏ´Â 10±â°¡ºñÆ® ¼­¹ö¿ÍÀÇ È¯»óÀÇ Á¶È­, NETGEAR ProSafe¢ç 28 port Gigabit Stackable Smart Switch´Â µ¥ÀÌÅÍ º¹»ç ¹× ¹é¾÷, °¡»óÈ­, Video on Demand ¹× ´ë¿ë·® Àü¼Û ÇÁ·Î¼¼½Ì µî°ú °°Àº ³ôÀº ´ë¿ªÆøÀ» ¿ä±¸ÇÏ´Â SMB ³×Æ®¿öÅ© ȯ°æ¿¡¼­ ÃÖ´ëÀÇ throughputÀ» º¸ÀåÇϱâ À§ÇØ 10 ±â°¡ºñÆ® Á¢¼ÓÀ» Áö¿øÇÏ´Â ¾÷°è ÃÖÃÊÀÇ ½º¸¶Æ® ½ºÀ§Ä¡ÀÔ´Ï´Ù. 
±âÁ¸ ¸Å´ÏÁöµå ½ºÀ§Ä¡ ´ëºñ ¹Ý°ªÀÇ ºñ¿ëÀ¸·Î ProSafe 28 Port Gigabit Smart Switch´Â µðÁöÅÐ Àåºñ ¿¬°áÀ» À§ÇÑ 24°³ÀÇ ±â°¡ºñÆ® Æ÷Æ®¿Í ¼­¹ö·ÎÀÇ ¾÷¸µÅ©, ȤÀº ½ºÅÂÅ·À» À§ÇÑ 4°³ÀÇ 10GE SFP+ Æ÷Æ®µéÀ» Á¦°øÇÕ´Ï´Ù. GS728TXS´Â GS752TXS¿Í °°Àº ½ºÅÃÀ» ÅëÇØ È¥¿ëÀ¸·Î ¿¬°áÇÒ ¼ö ÀÖÀ¸¸ç, ÃÖ´ë 6´ëÀÇ ½ºÀ§Ä¡µéÀ» ½ºÅÃÇÔÀ¸·Î½á ÅäÅ» 300°³ÀÇ ³×Æ®¿öÅ© Æ÷Æ®µéÀ» Á¦°ø ¿ùµîÇÑ ½Å·Ú¼ºÀ» À§ÇÑ Ç® ¸®´ø´ø½Ã¸¦ º¸ÀåÇÕ´Ï´Ù. GS728TXS´Â °í±Þ Æ®·¡ÇÈ °ü¸® ¹× º¸¾È ±â´É µîÀ» Æ÷ÇÔÇÑ Ç³ºÎÇÑ ¿£ÅÍÇÁ¶óÀÌÁî±Þ ±â´ÉÀ» Á¦°øÇϸç À¥ ±â¹ÝÀÇ ±×·¡ÇÈ À¯Àú ÀÎÅÍÆäÀ̽º¸¦ ÅëÇØ º¸´Ù ¼Õ½¬¿î ¼³Á¤ ¹× ¸ð´ÏÅ͸µÀ» µµ¿ÍÁÝ´Ï´Ù. 


¿£ÅÍÇÁ¶óÀÌÁî °ü¸® ±â´É

dzºÎÇÑ Layer 2 °ü¸® ±â´ÉµéÀ» ÅëÇØ GS728TXS´Â ¹Ì·¡ ȯ°æ¿¡µµ ÀûÇÕÇÑ È¿À²¼º°ú ¾ÈÀü¼ºÀ» ¾à¼ÓÇÕ´Ï´Ù. Static RoutingÀº ÀÌ ½ºÀ§Ä¡¸¦ ÅëÇØ ³»ºÎ ¶ó¿ìÆÃÀ» °¡Áö°í ³×Æ®¿öÅ©¸¦ ¼¼±×¸ÕÆ® ÇÒ ¼ö ÀÖ°Ô µµ¿ÍÁÖ¸ç ¶ó¿ìÅÍ´Â ¿ÀÁ÷ ¿ÜºÎ Æ®·¡ÇÈ ¶ó¿ìÆÿ¡ °ü¿©Çϵµ·Ï µµ¿ÍÁÖ¾î Àüü ³×Æ®¿öÅ©¸¦ ´õ¿í È¿À²ÀûÀ¸·Î ¸¸µé¾î ÁÝ´Ï´Ù. Dynamic 
VLAN ÁöÁ¤Àº Áö¼ÓÀûÀÎ Á¤Ã¥ ¹× ³×Æ®¿öÅ©¿¡ Á¢¼Ó °¡´ÉÇÑ »ç¿ëÀÚ¸¦ ½É¾îÁÜÀ¸·Î½á »ç¿ëÀÚ°¡ ¾îµð¿¡ Á¢¼ÓÇØ ÀÖµçÁö »ó°ü¾øÀÌ ³ôÀº º¸¾È ¼öÁØÀ» º¸ÀåÇÕ´Ï´Ù. MLD Snooping Áö¿øÀº ¸ðµç Æ÷Æ®µé¿¡¼­ ¸ÖƼij½ºÆ® ÆÐŶµéÀ» »Ñ·ÁÁö±â º¸´Ù´Â ¿ÀÁ÷ ÁöÁ¤µÈ È£½ºÆ®¿¡°Ô¸¸ ¸ÖƼij½ºÆ® Æ®·¡ÇÈÀ» Àü´ÞÇÔÀ¸·Î½á ³×Æ®¿öÅ© È¿À²¼ºÀ» Áõ´ë½Ãų ¼ö ÀÖ½À´Ï´Ù. GS728TXS´Â Ç® IPv6 Áö¿øÀº ¹°·Ð ±¤¹üÀ§ÇÑ º¸¾È ±â´É, °í±Þ ¸ÖƼij½ºÆ® °ü¸® ±â´É µîÀ» Á¦°øÇÕ´Ï´Ù. 

³ôÀº ½Å·Ú¼º, Æí¸®ÇÑ È®À强

GS728TXS´Â ºñÁî´Ï½º¿Í ÇÔ²² ¼ºÀåÇÒ ¼ö ÀÖ´Â È®Àå °¡´É ¼Ö·ç¼Ç ÀÔ´Ï´Ù. ÇÑ´ëÀÇ ½ºÀ§Ä¡¿¡¼­ Ãâ¹ßÇÏ¿© GS752TXS¿Í ÇÔ²² µ¿½Ã ¿¬°áÀÌ °¡´ÉÇϸç ÃÖ´ë 6´ëÀÇ ½ºÀ§Ä¡±îÁö ½ºÅÃÀÌ °¡´ÉÇÏ¿© ÃÑ 300°³ÀÇ ³×Æ®¿öÅ© Æ÷Æ®¸¦ Á¦°øÇÒ ¼ö ÀÖ½À´Ï´Ù. °¢ ½ºÀ§Ä¡¿¡ ÀÖ´Â 4°³ÀÇ 10 ±â°¡ºñÆ® SFP+ Æ÷Æ®µé Áß 2°³´Â ±× ½ºÅÃÀ» À§ÇØ »ç¿ë °¡´ÉÇϸç ÃÖ´ë 40GbpsÀÇ ½ºÅÂÅ· backplaneÀ» °¡Áø ÇϳªÀÇ logical unitÀÎ ÇϳªÀÇ ½ºÀ§Ä¡·Î ¼³Á¤ ¹× °ü¸®°¡ °¡´ÉÇÏ¿© ¼Õ½¬¿î ¹èÄ¡¿Í À¯Áö °ü¸®ÀÇ Æí¸®¼ºÀ» ¸¸³£ÇÒ ¼ö ÀÖ½À´Ï´Ù. 
½ºÅÃµÈ ½ºÀ§Ä¡µéÀº SFP+ Fiber optic Á¢¼ÓÀ» »ç¿ëÇÔÀ¸·Î½á ´Ù¼öÀÇ ¹°¸®ÀûÀÎ Àå¼Ò¿¡ ¶³¾î¶ß·Á ¹èÄ¡ÇÏ´Â °Ô °¡´ÉÇÏ¿© ¿ø°ÝÁö ȤÀº Áö»ç¿¡¼­ »ç¿ëÇϴµ¥ ÀÌ»óÀûÀÎ ¼Ö·ç¼ÇÀÔ´Ï´Ù. ¸ðµç 4°³ÀÇ 10GE Æ÷Æ®µéÀº ¼­¹ö ¹× ½ºÅ丮Áö Àåºñ¿ÍÀÇ ¾÷¸µÅ© Á¢¼ÓÀ» À§ÇØ »ç¿ëÇÒ ¼ö ÀÖÀ¸¸ç, ȤÀº 2°³´Â ±Ù°Å¸® ȤÀº ¿ø°Å¸® ½ºÅÂÅ·À» À§ÇØ ³ª¸ÓÁö 2°³´Â ¾÷¸µÅ© ȤÀº Link aggregationÀ» À§ÇØ ºÐ¸®Çؼ­ »ç¿ëÀÌ °¡´ÉÇÕ´Ï´Ù. Auto Failover ±â´ÉÀº ½ºÅà »ó¿¡ ÀÖ´Â ÇϳªÀÇ ½ºÀ§Ä¡°¡ °íÀå ½Ã¿¡µµ ¸ðµç ´Ù¸¥ ½ºÀ§Ä¡µéÀÌ ¿µÇâÀ» ¹ÞÁö ¾Êµµ·Ï ¾ÈÀüÇÑ ³×Æ®¿öÅ© ÀÛµ¿À» º¸ÀåÇØ ÁÝ´Ï´Ù. 

À¯¿¬ÇÑ ¸Å´ÏÁö¸ÕÆ® ¿É¼Ç

"Smart" Switch·Î¼­ IT°ü¸®ÀÚµéÀº GS728TXS¸¦ ¾î¶»°Ô °ü¸®ÇÒ °Í ÀÎÁö¸¸À» °áÁ¤ÇÏ¸é µË´Ï´Ù. °¢°¢ÀÇ ½ºÀ§Ä¡µéÀº ¸ðµÎ ÇϳªÀÇ °£ÆíÇÑ À¥ ±â¹Ý ±×·¡ÇÈ À¯Àú ÀÎÅÍÆäÀ̽º¸¦ ÅëÇØ °ü¸®µÉ ¼ö ÀÖ½À´Ï´Ù. GS728TXS´Â ¶ÇÇѱâÁ¸ SNMP ±â¹Ý ÄְܼúÀÇ È£È¯¼ºÀ» À§ÇØ SNMP ¼ÒÇÁÆ®¿þ¾î¸¦ ÅëÇØ °ü¸®µÉ ¼öµµ ÀÖ½À´Ï´Ù. º¸´Ù Å« ³×Æ®¿öÅ©¸¦ À§Çؼ­ NETGEARÀÇ Smart Control Center´Â ¹«·á Windows ±â¹Ý ¾îÇø®ÄÉÀ̼ÇÀ» Á¦°ø ³×Æ®¿öÅ© »ó¿¡ ÀÖ´Â ¸ðµç ½º¸¶Æ® ½ºÀ§Ä¡µéÀ» ŽÁöÇÏ°í, ¼³Á¤Çϸç, ¾÷±×·¹À̵åÇÒ ¼öÀÖ½À´Ï´Ù. ¸ðµç´Ù¸¥ NETGEARÀÇ ProSAFE ½º¸¶Æ® ½ºÀ§Ä¡µéó·³ GS728TXS ¿ª½Ã NETGEAR ProSAFE Lifetime Warranty¸¦ º¸Àå ¹ÞÀ» ¼ö ÀÖ½À´Ï´Ù.


 

Çϵå¿þ¾î ÁÖ¿ä ±â´É Àå Á¡
10±â°¡ºñÆ® Á¢¼Ó 10GE ¼­¹öµéÀÇ °­·ÂÇÑ ÆÄ¿ö Áö¿ø 

µ¥ÀÌÅÍ ¹é¾÷ ¹× º¹»ç, °¡»óÈ­, VoD, ´ë¿ë·® Àü¼Û ÇÁ·Î¼¼½Ì µî ³ôÀº ´ë¿ªÆø ¾îÇø®ÄÉÀÌ¼Ç Áö¿ø
ÃÖ´ë 6´ë ½ºÀ§Ä¡ ½ºÅà °­·ÂÇÑ 10GE ¼­¹öÀÇ ÈûÀ» ¸¸³£ÇÒ ¼ö ÀÖÀ½. 

µ¥ÀÌÅÍ ¹é¾÷, º¹Á¦, °¡»óÈ­, Video on demand ¹× °í¿ë·® µ¥ÀÌÅÍ Ã³¸® µî ³ôÀº ´ë¿ªÆøÀ» ¿äÇÏ´Â ¾îÇø®ÄÉÀÌ¼Ç Áö¿ø 

¿£ÅÍÇÁ¶óÀÌÁî¿Í ÇÔ²² ¼ºÀåÀÌ °¡´ÉÇÑ È®Àå°¡´ÉÇü ½ºÀ§Ä¡ 

½ºÅÃ»ó¿¡ ÀÖ´Â ½ºÀ§Ä¡ Çϳª°¡ °íÀ峪µµ ³ª¸ÓÁö ½ºÀ§Ä¡¿£ ¿µÇâÀ» ÁÖÁö ¾Ê´Â Auto Failover ±â´É
4°³ 10GE SFP+ ½ºÅÂÅ·/¾÷¸µÅ© Æ÷Æ® ÃÖ´ë 40GbpsÀÇ Stacking backplane 

Fiber optic Á¢¼ÓÀ» ÅëÇØ ½ºÀ§Ä¡µéÀº ¿ø°Ý ȤÀÎ Áö»ç¿Í °°Àº ´Ù¼öÀÇ ¹°¸®Àû Àå¼Ò¿¡ ¹èÄ¡ °¡´É
¼ÒÇÁÆ®¿þ¾î ÁÖ¿ä ±â´É Àå Á¡
Dynamic VLAN ÁöÁ¤ »ç¿ëÀÚÀÇ À§Ä¡¿¡ »ó°ü¾øÀÌ Áö¼ÓÀûÀÎ Á¤Ã¥°ú ³×Æ®¿öÅ© Á¢¼Ó »ç¿ëÀÚ Çã°¡¸¦ ºÎ¿©ÇÔÀ¸·Î½á º¸¾È °­È­
MLD snooping ¸ðµç Æ÷Æ®µé¿¡°Ô ¸ÖƼij½ºÆ® ÆÐŶÀ» Àü¼ÛÇϱ⺸´Ù´Â ÁöÁ¤µÈ È£½ºÆ®¿¡°Ô¸¸ ¸ÖƼij½ºÆ® Æ®·¡ÇÈÀ» Àü¼ÛÇÔÀ¸·Î½á ³×Æ®¿öÅ© È¿À²¼º Áõ´ë
IPv6 Ç® Áö¿ø Â÷¼¼´ë ¾îÇø®ÄÉÀÌ¼Ç ¹× È®Àå ¹öÀüÀ» ¸ðµÎ Áö¿øÇϵµ·Ï ¹Ì·¡ ÁöÇâ ³×Æ®¿öÅ©·Î ITÅõÀÚ ºñ¿ë Àý¾à
DHCP snooping IP to MAC binding Á¤º¸¸¦ È°¿ëÇÔÀ¸·Î½á DHCP ¼­¹ö °ø°Ý°ú °°Àº Access Layer Attack, ARP man-inthe-middle attack ¹× IP/MAC snooping attackµî ¿¹¹æ
Æ÷Æ® º¸È£ °°Àº ½ºÀ§Ä¡ »ó¿¡¼­µµ ƯÁ¤ Æ÷Æ®µéÀ» ´Ù¸¥ Æ÷Æ®µé°ú Ä¿¹Â´ÏÄÉÀÌ¼Ç Â÷´ÜÀ» ÅëÇØ º¸¾È °­È­ 

Áß¿äÇÑ ¼­ºñ½º ¹× Á¤º¸ ½ÀµæÀ» À§ÇØ °ø°ÝÀÚµéÀÇ ½Ã½ºÅÛ ½ºÄ³´× ¹æÁö
GS728TXS ¹× GS752TXS È¥ÇÕ ½ºÅà °¡´É ³×Æ®¿öÅ© ¼³Á¤½Ã À¯¿¬¼º Á¦°ø. 
³×Æ®¿öÅ© ¸®¼Ò½ºÀÇ ³ôÀº È°¿ëµµ¸¦ º¸ÀåÇϸ鼭 ±Í»ç¿¡ ÇÊ¿äÇÑ ³×Æ®¿öÅ© È®Àå °¡´É


GS728TXS Diagram


Network Protocol and Standards Compatibility

  • IEEE 802.3 10BASE-T
  • IEEE 802.3u 100BASE-TX
  • IEEE 802.3ab 1000BASE-T
  • IEEE 802.3z 1000BASE-X
  • IEEE 802.3x full-duplex flow control
  • IEEE802.3aq (10GBASE-LRM)
  • IEEE802.3ae (10Gbase Ethernet
  • IEEE802.3az (EEE)

Interfaces

  • 24 10/100/1000 Mbps switching ports
  • 4-10GEbps SFP+ slots (port 25~28) to support 10GEbps optical module and 1G optical module
  • Port 27 and port 28 can be used as the stacking ports or as uplink ports.
    • Auto-sensing and auto-negotiating capabilities for all copper ports
    • Auto Uplink¢â on all ports to make the right connection

Administrative Switch Management

  • IEEE 802.1Q VLAN (256 groups, Static)
  • IEEE 802.1p Class of Service (CoS)
  • 8 hardware queues
  • Port-based QoS
  • IEEE 802.3ad Static or Dynamic Link Aggregation (LACP)
  • IEEE 802.1D Spanning Tree Protocol
  • IEEE 802.1w Rapid Spanning Tree Protocol
  • IEEE 802.1s Multiple Spanning Tree Protocol
  • SNMP v1, v2c, v3
  • RFC 1213 MIB II
  • RFC 1643 Ethernet Interface MIB
  • RFC 1493 Bridge MIB
  • RFC 2131 DHCP client
  • IEEE 802.1x (RADIUS)
  • IEEE 802.1x Dynamic VLAN Assignment
  • HTTPS/SSL: Secure HTTP GUI
  • RADIUS accounting
  • Layer 3 (DSCP) Quality of Service (QoS)
  • TACACS+
  • Port-based security by locked MAC addresses
  • TCP/UDP-based priority mapping
  • IGMP snooping v1, v2, v3
  • MLD Snooping
  • ACLs (MAC, IPv4, IPv6 and TCP/UDP based)
  • Storm control for broadcast, multicast and unknown unicast packets
  • Port-based rate limiting
  • SNTP
  • DNS
  • DoS and Auto DoS prevention
  • IPv6 management, multicast and QoS
  • Static Routing
  • DHCP Snooping
  • Green Features: Lower power consumption during link-down mode or EEE mode
  • Protocol and MAC based VLAN
  • RMON group 1, 2, 3, 9
  • Private Enterprise MIB
  • Port mirroring – many-to-one
  • IEEE 802.3ab LLDP
  • LLDP-MED
  • Protected ports
  • Cable test
  • Smart Control Center discovery
  • Web-based configuration
  • Configuration backup/restore
  • Password access control
  • Firmware upgradeable

Performance Specifications

  • Forwarding modes: Store-and-forward
  • Bandwidth: 128 Gbps
  • Stacking up to 6 switches or 300 ports per stack
  • Stacking bandwidth: 40 Gbps
  • Network latency: Less than 20 microseconds for 64-byte frames in store and forward mode for 1000 Mbps to 1000 Mbps transmission
  • Buffer memory: 2 MB
  • 128Mbytes System DDR SDRAM (32Mbx16).
  • 32Mbytes flash memory.
  • Address database size: 16K media access control (MAC) addresses per system
  • Addressing: 48-bit MAC address
  • 256 VLANs; Maximum VLAN id is 4093
  • 7 802.1p traffic classes
  • 8 LAGs
  • 32 static routes
  • 15 routed VLANs
  • 1024 ARP Cache entries
  • 7 queues used for DiffServ
  • 100 ACLs (MAC/IPv4/IPv6)
  • 8K DHCP snooping binding
  • 1024 DHCP static entries
  • Mean time between failures (MTBF):
    • 677,816 hours (~77.3 years) at 25 ¡ÆC
    • 200,444 hours (~22.9 years) at 55 ¡ÆC

LEDs

  • Unit: Power, master, stack ID, FAN
  • Per port: Link, speed, activity

Power Supply

  • Max Power consumption: 31.4w
  • 100-240V AC/50-60 Hz universal input

Physical Specifications

  • Dimensions: (h x w x d): 43 x 440 x 257 mm (1.69 x 17.32 x 10.13 in)
  • Weight: 3.55kg (7.83 lbs)
  • Acoustic Noise Level @ 25C: 32.9dBA MTBF: 677,816 hours

Environmental Specifications

  • Operating temperature: 32¡Æ to 104¡Æ F (0¡Æ to 50¡Æ C)
  • Storage temperature: -4¡Æ to 158¡Æ F (-20¡Æ to 70¡Æ C)
  • Operating humidity: 95% maximum relative humidity, non-condensing
  • Storage humidity: 95% maximum relative humidity, non-condensing
  • Operating altitude: 10,000 ft (3,000 m) maximum
  • Storage altitude: 10,000 ft (3,000 m) maximum

Electromagnetic Compliance

  • CE mark, commercial
  • FCC Part 15 Class A
  • VCCI Class A
  • EN 55022 (CISPR 22),
  • EN 55024 (CISPR 24)
  • C-Tick

Safety

  • CE mark, commercial
  • CUL 60950 (Listed)/EN 60950 (Low Voltage Directive)

System Requirements

  • Category 5 UTP Network cables or better
  • Network card for each PC
  • Network software (e.g., Windows7)

Warranty and Support

  • ProSafe Lifetime Warranty¢Ó
  • ProSupport 24x7 Advanced Technical Support, 1 year (included)*

ProSupport¢â Service Packs Available

  • XPressHW, Category 2: PRR0332 (3-year next-business day hardware replacement contract)
  • OnCall 24x7, Category 2: PMB0332 (3-year Advanced Technical Support contract, including Remote Diagnostics performed by our technical experts for prompt resolution of technical issues, and next-business day hardware replacement)

Package Contents

  • ProSAFE¢ç 28-Port Gigabit Stackable Smart Switch with 10GE uplinks
  • Rubber footpads
  • Power cord
  • Rack-mount kit
  • Resource CD installation guide
  • Warranty/support information card

Modules

  • AXM761 ProSAFE 10GEBASE-SR SFP+ GBIC
  • AXM762 ProSAFE 10GEBASE-LR SFP+ GBIC
  • AXM763 ProSAFE 10GEBASE-LRM SFP+ GBIC
  • AXC761 1m Direct Attach SFP+ Cable
  • AXC763 3m Direct Attach SFP+ Cable
  • AGM731F ProSAFE 1000BASE-SX SFP GBIC: Module with LC connectors for 50um or 62.5um multi-mode fiber cable
  • AGM732F ProSafe 1000BASE-LX SFP GBIC: Module with LC connectors for 9um single-mode fiber cable
  • AGM733 ProSAFE

Ordering Information

  • North America: GS728TXS-100NES
  • Europe, Korea: GS728TXS-100NES
  • Asia/Japan: GS728TXS-100AJS
  • China: GS728TXS-100PRS




 
Åùè, È­¹°, Äü¼­ºñ½º µî ´Ù¾çÇÑ ¿î¼Û¹æ¹ýÀ» ÀÌ¿ëÇÏ¿© ¹è¼ÛÀÌ °¡´ÉÇÕ´Ï´Ù.

¿îÀÓºñ´Â ±¸¸ÅÀÚ ºÎ´ãÀÔ´Ï´Ù.
°¢ Á¦Á¶»çÀÇ A/S ±ÔÁ¤¿¡ µû¸¨´Ï´Ù.
¼ÒºñÀÚ º¸È£¹ý¿¡ µû¸¨´Ï´Ù.

¹®ÀÇ : 02-7989-114
 
 
 
 
 
À̸§ :
³»¿ë :
ÆòÁ¡
°í°´Æò°¡ : ÆòÁ¡ ¡Ú¡Ú¡Ú¡Ú¡Ú  
 
 
 
 
»óÇ°¿¡ ´ëÇØ ±Ã±ÝÇÑ Á¡À» ÇØ°áÇØ µå¸³´Ï´Ù.
¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ Á¶È¸
 
 
»óÇ°Èı⸦ ÀÛ¼ºÇØ ÁÖ¼¼¿ä.
 

Copyright ¨Ï ·£Àåºñ All Rights Reserved. TEL : 02-798-9114 , FAX : 02-716-7229
»óÈ£¸í : (ÁÖ)·£Àåºñ   »ç¾÷ÀÚµî·Ï¹øÈ£ : 106-86-16143 106-86-16143   Åë½ÅÆǸž÷½Å°í¹øÈ£ : Á¦ 2006-¼­¿ï¿ë»ê-00850È£   ´ëÇ¥ : ¾È±âÁß
[ÀÌ¿ë¾à°ü°³ÀÎÁ¤º¸Ãë±Þ¹æħ °³ÀÎÁ¤º¸´ã´çÀÚ : ¹Ú¿ë±¸ºÎÀå   »ç¾÷Àå¼ÒÀçÁö : ¼­¿ï ¿ë»ê±¸ ûÆÄ·Î 83, 4µ¿9¿­ 2,3È£(¿øÈ¿·Î3°¡,¿øÈ¿ÀüÀÚ»ó°¡)