º¸¾È Á¢¼Ó
·Î±×ÀÎ
|
ȸ¿ø°¡ÀÔ
|
Àå¹Ù±¸´Ï
|
°í°´¼¾ÅÍ
TEL : 02-798-9114
HPE-ARUBA
[ÆÄ°Ý°¡]
CISCO
[ƯÆǸðµ¨]
D-Link
[Àü±¹ÃÖÀú°¡]
NETGEAR
[ÃÖÀú°¡°ø±Þ]
Alcatel-Lucent Enterprise
½Ã½ºÄÚ Cisco
Cisco SB/Pro
ZyXEL
APC
[Àüȹ®ÀÇ]
¼ÖÅØ(Soltech)
TP-LINK
¿¡ÀÌÅÙ[ATEN]
µðÆ÷±×(Defog)
DASAN(´Ù»ê)
UTM/VPN/¹æȺ®
ETK
¹«¼±·£/Wireless
¹«¼±°øÀ¯±â/¹«¼±AP/¾ÈÅ׳ª
À¯¼±Àåºñ/Network
½ºÀ§Ä¡/·£Ä«µå/ÇÁ¸°Åͼ¹ö
POE ½ºÀ§Ä¡
10±â°¡ºñÆ® ÀÌ´õ³Ý
·£°ø±¸,CCTV ÀâÀÚÀç
FIBER
Àåºñ/Á¡ÆÛÄÚµå
RACK/UPS/KVM
°¢Á¾ÄÉÀ̺í/Á¨´õ
¿µ»ó/À½Çâ/ºÐ¹è±â/°øÀ¯
½Ã¸®¾ó Åë½ÅÁ¦Ç°
¸ÖƼÆ÷Æ®/ÄÁ¹öÅÍ
»ê¾÷¿ë Á¦Ç°±º
CCTV ºñµð¿À¼¹ö
USB/1394/ÁÖº¯±â±â
======================
AP
HIKVISION
INTEL
MOXA
Chesio (10G NIC)
IPTIME
Uniclass KVM
TYCO(AMP)
3COM
Britz
======================
°¡°ÝÁ¶Á¤
======================
802.11N
UBIQUITI
·£Àåºñ ¼Ò½Ä/¹®ÀÇ
°ø±Þ/±¸Ãà»ç·Ê
(ÁÖ)·£Àåºñ ÀÚ·á½Ç
ºñ¹Ð¹øÈ£
À¯¼±Àåºñ/Network
½ºÀ§Ä¡/·£Ä«µå/ÇÁ¸°Åͼ¹ö
À¯¼±Àåºñ/Network
½ºÀ§Ä¡/·£Ä«µå/ÇÁ¸°Åͼ¹ö
>
½Ã½ºÄÚ ½ºÀ§Ä¡
>
Cisco [WS-C3550-24-EMI]
ÀÌÀü»óÇ°
Cisco [WS-C3550-24-EMI]
´ÙÀ½»óÇ°
ÆǸŰ¡°Ý :
12,463,000¿ø
¼ö·®
EA
Cisco Catalyst 3550 Series
Intelligent Ethernet Switches for
Metro Access
Á¦Ç° °³¿ä
CCisco Catalyst¢ç 3550 Series Intelligent Ethernet Switch´Â Áö´É¼ºÀ» ¸ÞÆ®·Î ¾×¼¼½º ¿¡Áö·Î È®ÀåÇÏ¿©
¼ºñ½º Æø, °¡¿ë¼º, º¸¾È ¹× Á¦¾î ±â´ÉÀ» Á¦°øÇÏ´Â »õ·Ó°í °·ÂÇÑ °íÁ¤ ±¸¼ºÇü ¸ÖƼ·¹ÀÌ¾î ½ºÀ§Ä¡ Á¦Ç°
±ºÀÔ´Ï´Ù . Cisco Metro Ethernet Switching Æ÷Æ®Æú¸®¿ÀÀÇ ÇÙ½É ¿ä¼ÒÀÎ ÀÌ ½ºÀ§Ä¡´Â ¼öÀͼº ÀÖ´Â ÀÌ´õ³Ý
¼ºñ½º¸¦ Á¦°øÇÏ¸é¼ Àüü ¼ÒÀ¯ ºñ¿ëÀº ÃÖ¼ÒÈÇÏ·Á´Â ¼ºñ½º Á¦°ø ¾÷üµé¿¡°Ô ¸Å¿ì ÀûÇÕÇÕ´Ï´Ù. °í¼Ó
ÀÌ´õ³Ý, ±â°¡ºñÆ® ÀÌ´õ³Ý, DC Àü¿ø ¹× ±¤¼¶À¯ ±¸¼º µîÀ» Æø³Ð°Ô ¼ö¿ëÇÏ´Â Cisco Catalyst 3550 Series´Â
¾ØÅÍÇÁ¶óÀÌÁî ¹× Áß¼Ò ±â¾÷ ½ÃÀå¿¡ ÀÌ»óÀûÀÎ ¸ÞÆ®·Î ¾×¼¼½º ½ºÀ§Ä¡ÀÔ´Ï´Ù. ÀÌ °í¼º´ÉÀÇ ºñ¿ë È¿À²ÀûÀÎ
½ºÀ§Ä¡ Á¦Ç°±ºÀº 802.1Q Åͳθµ, °í¼º´É IP ¶ó¿ìÆà ¹× ¼ºê¼¼ÄÁµå STP(Spanning-Tree Protocol) ÄÁ¹ö
Àü½º ±â´ÉÀ» °®Ãç.TLS(Transparent LAN Services) ¹× ºñÁî´Ï½º±Þ ÀÎÅÍ³Ý ¾×¼¼½º °°Àº ´Ù¾çÇÑ ¸ÞÆ®·Î
¼ºñ½º¸¦ Á¦°øÇÕ´Ï´Ù.
Cisco Catalyst 3550 Series Intelligent Ethernet Switch´Â ´ÙÀ½°ú °°Àº ±¸¼ºÀ¸·Î ÀÌ·ç¾îÁ® ÀÖ½À´Ï´Ù.
Cisco Catalyst 3550-24 Switch-
24°³ÀÇ 10/100 Æ÷Æ®, 2°³ÀÇ GBIC(Gigabit Interface Converter) ±â¹Ý ±â°¡ºñÆ® ÀÌ´õ³Ý Æ÷Æ® ¹× 1RU(rack
unit)
Cisco Catalyst 3550-24-DC Switch- 24 °³ÀÇ 10/100 Æ÷Æ®, 2°³ÀÇ GBIC ±â¹Ý ±â°¡ºñÆ® ÀÌ´õ³Ý Æ÷Æ®
¹× DC Àü¿øÀÇ 1 RU
Cisco Catalyst 3550-24-FX Switch- 24 °³ÀÇ100FX ¸ÖƼ¸ðµå ÆÄÀ̹ö Æ÷Æ®, 2 °³ÀÇ GBIC ±â¹Ý ±â°¡ºñ
Æ® ÀÌ´õ³Ý Æ÷Æ® ¹× 1 RU
Cisco Catalyst 3550-48 Switch-
48 °³ÀÇ 10/100 Æ÷Æ®, 2°³ÀÇ GBIC ±â¹Ý ±â°¡ºñÆ® ÀÌ´õ³Ý Æ÷Æ® ¹× 1 RU
Cisco Catalyst 3550-12G Switch- 10 °³ÀÇ GBIC ±â¹Ý ±â°¡ºñÆ® ÀÌ´õ³Ý Æ÷Æ®, 2°³ÀÇ
10/100/1000BaseT Æ÷Æ® ¹× 1.5 RU
Cisco Catalyst 3550-12T Switch- 10 °³ÀÇ 10/100/1000BaseT Æ÷Æ®, 2 °³ÀÇ GBIC ±â¹Ý ±â°¡ºñÆ® ÀÌ
´õ³Ý Æ÷Æ® ¹× 1.5 RU
³»ÀåµÈ ±â°¡ºñÆ® ÀÌ´õ³Ý Æ÷Æ®¿¡´Â Cisco CWDM(Course Wave Division Multipelxing) GBIC ¼Ö·ç¼Ç,
GigaStack¢ç GBIC, 1000BaseT, 1000BaseSX, 1000BaseLX/LH ¹× 1000BaseZX¸¦ ºñ·ÔÇØ ´Ù¾çÇÑ
GBIC Æ®·£½Ã¹ö¸¦ ¿¬°áÇÒ ¼ö ÀÖ½À´Ï´Ù. ¶ÇÇÑ ÀÌÁß ¸®´ø´ø½ÃÇü ±â°¡ºñÆ® ÀÌ´õ³Ý ¾÷¸µÅ©, UplinkFast ¹× ¾÷
¸µÅ© ·Îµå ¹ë·±½ÌÀ» À§ÇÑ PVST+(Per-VLAN Spanning Tree Plus)¸¦ Áö¿øÇÔÀ¸·Î½á ³ôÀº ¼öÁØÀÇ º¹¿ø·Â
À» ±¸ÇöÇÒ ¼ö ÀÖ½À´Ï´Ù. ÀÌ·¯ÇÑ ±â°¡ºñÆ® ÀÌ´õ³ÝÀÇ À¯¿¬¼ºÀ¸·Î Cisco Catalyst 3550 Series ½ºÀ§Ä¡´Â
Cisco 7600 Series ÀÎÅÍ³Ý ¶ó¿ìÅÍ ¹× Catalyst 6500 Series ¸ÞÆ®·Î ÀÌ´õ³Ý ½ºÀ§Ä¡¸¦ º¸¿ÏÇÏ´Â ¸ÞÆ®·Î ¾×
¼¼½º ¿¡Áö·Î ÀÌ»óÀûÀÔ´Ï´Ù.
Cisco Catalyst 3550-24 ¹× 3550-48¿¡´Â SMI(Standard Multilayer Software Image) ¶Ç´Â EMI
(Enhanced Multilayer Software Image)°¡ Æ÷ÇԵǾî ÀÖ½À´Ï´Ù. EMI´Â VLAN(Virtual LAN) °£ ¶ó¿ìÆÃ,
RACL(Router Access Control List) ¹× HSRP(Hot Standby Router Protocol)¸¦ ºñ·ÔÇØ º¸´Ù dzºÎÇÑ ±â
´ÉÀ» Á¦°øÇÕ´Ï´Ù. Ãʱ⠼³Ä¡°¡ ¿Ï·áµÇ¸é Enhanced Multilayer Software Image ¾÷±×·¹À̵å Å°Æ®¸¦ »ç¿ë
ÇÏ¿© EMI·Î ¾÷±×·¹À̵åÇÒ ¼ö ÀÖ½À´Ï´Ù. EMI¸¦ »ç¿ëÇØ ¾÷±×·¹À̵尡 °¡´ÉÇÑ ¸ðµ¨·Î´Â Cisco Catalyst
3550-12T ¹× 3550-12G°¡ ÀÖ½À´Ï´Ù.
±×¸² 1
Cisco Catalyst 3550-24 Intelligent Ethernet Switch
±×¸² 2
Cisco Catalyst 3550-24-DC Intelligent Ethernet Switch
±×¸² 3
Cisco Catalyst 3550-24-FX Intelligent Ethernet Switch
±×¸² 4
Cisco Catalyst 3550-48 Intelligent Ethernet Switch
±×¸² 5
Cisco Catalyst 3550-12G ¹× 3550-12T Intelligent Ethernet Switch
Áö´ÉÇü ¸ÞÆ®·Î ¾×¼¼½º ¿¡Áö: ¼öÀͼº dzºÎÇÑ ÀÌ´õ³Ý ¼ºñ½º ½ÇÇö
¼ºñ½º Á¦°ø ¾÷üµéÀº ´ë±â¾÷ ¹× Áß¼Ò±â¾÷ °í°´µéÀÇ ¼ºñ½º ¿ä±¸¸¦ ¸¸Á·½ÃÅ°´Â µ¥ ÀÖ¾î ½É°¢ÇÑ ³Á¦¿¡
ºÎµúÈ÷°í ÀÖ½À´Ï´Ù. °í°´µéÀÌ ÀڽŵéÀÇ ³×Æ®¿öÅ©¿¡¼ Á¡Á¡ ´õ ¸¹Àº Áß¿ä ¾÷¹«¿ë ¾ÖÇø®ÄÉÀ̼ÇÀ» »ç¿ëÇÔ
¿¡ µû¶ó T1/E1º¸´Ù ºü¸¥ ¼Óµµ¿¡ °¡°Ý °æÀï·ÂÀ» °®Ãá °í´ë¿ªÆøÀ» ¿ä±¸ÇÏ°í ÀÖ½À´Ï´Ù. ´ë±â¾÷ ¹× Áß¼Ò±â¾÷
°í°´µéÀº LAN¿¡¼ ÀÌ´õ³ÝÀÌ °¡Á®´Ù ÁÖ´Â ¼Óµµ ¹× ºñ¿ë»óÀÇ ÀÌÁ¡À» °æÇèÇßÀ¸¸ç, ÀÌ·¯ÇÑ ÀÌÁ¡À» WAN
(Wide-Area Network) ¹× MAN(Metro-Area Network)À¸·Î È®ÀåÇÏ±æ ¹Ù¶ó°í ÀÖ½À´Ï´Ù. ÇÏÁö¸¸ ¿À´Ã³¯°ú
°°Àº °æÁ¦ »óȲ¿¡¼ °í°´µéÀÇ ¼ºñ½º ¿ä±¸¸¦ ¸¸Á·½ÃÅ°±â À§ÇØ ¼ºñ½º Á¦°ø ¾÷üµéÀº ¸î °¡Áö µµÀü¿¡ Á÷
¸éÇÏ°Ô µË´Ï´Ù. ¼ºñ½º Á¦°ø ¾÷üµéÀÌ Á÷¸éÇÏ°í ÀÖ´Â µµÀüµéÀº ´ÙÀ½°ú °°½À´Ï´Ù.
¼öÀͼº dzºÎÇÑ »õ·Î¿î ¼ºñ½º¸¦ Á¦°øÇÔ°ú µ¿½Ã¿¡ ¿î¿µ ¹× ÀÚº» ºñ¿ë Àý°¨
T1/E1º¸´Ù ºü¸¥ ¼ÓµµÀÇ °¡º¯ ´ë¿ªÆø ¿ä±¸¿¡ ºÎÇÕ
ÇÁ·¹ÀÓ ¸±·¹ÀÌ(Frame Relay) ¹× ATM(Asynchronous Transfer Mode) °°Àº ±âÁ¸ WAN ¼ºñ½ºÀÇ È¿
À²ÀûÀÎ ÅëÇÕ
°æÁ¦ÀûÀÌ¸é¼ È¿¿ë °¡Ä¡°¡ ³ô°í È®Àå °¡´ÉÇÑ ¸ÞÆ®·Î ÀÌ´õ³Ý ³×Æ®¿öÅ© ±¸Ãà
ƯÈ÷ ¸ÞÆ®·Î ¾×¼¼½º ¿¡Áö¿¡¼´Â ÀÌ·¯ÇÑ ³Á¦µéÀÌ ´õ¿í È®¿¬È÷ ³ªÅ¸³ª°í ÀÖ½À´Ï´Ù. ¼ºñ½º Á¦°ø ¾÷üµéÀÌ
Layer 2 VPN(Layer 2 Virtual Private Network)À̳ª ºñÁî´Ï½º ÀÎÅÍ³Ý ¾×¼¼½º °°ÀÌ ¼öÀͼº ÀÖ´Â ÀÌ´õ³Ý
¼ºñ½º¸¦ Á¦°øÇÏ·Á ÇÔ¿¡ µû¶ó ÀÌ·¯ÇÑ ¾÷üµéÀÇ CLE(Customer Located Equipment)¿¡´Â 802.1Q ÅͳÎ
¸µ, °í±Þ QoS ¹× ¼¼ºÐÈµÈ ¼Óµµ Á¦ÇÑ °°Àº CiscoÀÇ Áö´ÉÇü ±â´ÉµéÀÌ ÁßÃßÀûÀÎ ¿ªÇÒÀ» ¼öÇàÇÏ°í ÀÖ½À´Ï
´Ù. °Ô´Ù°¡ Cisco Catalyst 3550 Series ½ºÀ§Ä¡´Â ¼ºê¼¼ÄÁµå STP ÄÁ¹öÀü½º ¹× CWDM GBIC Áö¿ø °°Àº
Áö´ÉÇü ±â´Éµé°ú ÇÔ²² ¾×¼¼½º ¿¡Áö¿¡ ÇʼöÀûÀÎ ³×Æ®¿öÅ© °¡¿ë¼º ¹× È®À强À» Á¦°øÇÕ´Ï´Ù. Cisco
Catalyst 3550 Series Intelligent Ethernet Switch´Â ¼º´É, °æÁ¦¼º ¹× Áö´É¼º °£¿¡ ÃÖÀûÀÇ ±ÕÇüÀ» ÀÌ·ç¾î
¼öÀͼº ÀÖ´Â ¼ºñ½º Æø, °¡¿ë¼º, º¸¾È ¹× °ü¸®»óÀÇ ¿ëÀ̼ºÀ» ½ÇÇöÇÕ´Ï´Ù.
¹«¾ùº¸´Ùµµ Cisco Catalyst 3550 Series´Â Cisco Metro Ethernet Switching ±¸¼º ¿ä¼ÒÀÇ ÇÙ½ÉÀÔ´Ï´Ù .
Cisco Metro Ethernet SwitchingÀº ¼ºñ½º Á¦°ø ¾÷üµéÀÌ Áö¿ª ¸ÞÆ®·Î, ¸ÞÆ®·Î ÁýÇÕ ¹× ¸ÞÆ®·Î ¾×¼¼½º¸¦
À§ÇØ ¼öÀͼº ÀÖ´Â Á¾ÇÕÀûÀÎ ÀÌ´õ³Ý ¼ºñ½º¸¦ Á¦°øÇÒ ¼ö ÀÖ°Ô ÇØ ÁÝ´Ï´Ù. Cisco Metro Ethernet
SwitchingÀº ÇÁ·¹ÀÓ ¸±·¹ÀÌ ¹× ATM °°Àº ±âº» WAN ¼ºñ½º¿ÍÀÇ È¿À²ÀûÀÎ ÅëÇÕÀ¸·Î ÃÖ»óÀÇ ¼ºñ½º Àü´Þ
¸ÞÄ¿´ÏÁò ÆøÀ» °®Ãß°í ÀÖ½À´Ï´Ù. Cisco´Â ¶ÇÇÑ ±¤¹üÀ§ÇÑ ÀÚµ¿È ¿î¿µ Áö¿øÀ» ÅëÇØ ¼ºñ½º Á¦°ø ¾÷üµéÀÌ
Àüü ¼ÒÀ¯ ºñ¿ëÀ» ÃÖ¼ÒÈÇϵµ·Ï µµ¿ÍÁÝ´Ï´Ù. ±â¼ú ¸®´õ½Ê, À繫ÀûÀÎ ¾ÈÁ¤¼º ¹× °í°´ Áö¿øÀ» ÇâÇÑ °ø¾àÀ»
¹ÙÅÁÀ¸·Î Cisco´Â ½ÃÀÛ¿¡¼ È®Àå ¼ºñ½º±îÁöÀÇ ¼º°øÀ» Ã¥ÀÓÁö°í ÀÖ½À´Ï´Ù.
802.1Q Åͳθµ, °í±Þ QoS ¹× ¼Óµµ Á¦ÇÑÀ» ÅëÇÑ ¼ºñ½º Æø
Cisco Catalyst 3550´Â 802.1Q Åͳθµ ±â´ÉÀ¸·Î ¼ºñ½º Á¦°ø ¾÷üµéÀÌ ´ë±â¾÷ ¹× Áß¼Ò±â¾÷ °í°´ ³×Æ®¿ö
Å©¿¡¼ ÀڽŵéÀÇ ³×Æ®¿öÅ©¸¦ ¿ÏÀüÈ÷ ºÐ¸®ÇÏ¿© Layer 2 TLS(Transparent LAN Service)¸¦ »ý¼ºÇÒ ¼ö ÀÖ
°Ô ÇØ ÁÝ´Ï´Ù. 802.1Q Åͳθµ ±¸ÇöÀ» ÀÌ¿ëÇÏ¸é ¼ºñ½º Á¦°ø ¾÷üµéÀÇ VLAN Á¤º¸(802.1Q ű×)´Â ÆÐŶÀÌ
¼ºñ½º Á¦°ø ¾÷üÀÇ ³×Æ®¿öÅ©¿¡ À¯ÀԵʿ¡ µû¶ó °í°´ÀÇ º»·¡ 802.1Q·Î ÅÂ±×µÈ ÆÐŶ¿¡ Ãß°¡µË´Ï´Ù. ¼ºñ½º
Á¦°ø ¾÷üÀÇ 802.1Q ű״ ÆÐŶÀÌ ³×Æ®¿öÅ©¸¦ ºüÁ®³ª°¡¸é Á¦°ÅµÇ¾î º»·¡ÀÇ Ã³¸®µÇÁö ¾ÊÀº »óÅ·Π³²¾Æ
ÀÖ½À´Ï´Ù. STP, VTP(VLAN Trunk Protocol) ¹× CDP(Cisco Discovery Protocol) °°Àº ´Ù¸¥ Layer 2 ÇÁ
·ÎÅäÄݵµ ¼ºñ½º Á¦°ø ¾÷üÀÇ ³×Æ®¿öÅ©¸¦ ÅëÇØ Åͳθµ µË´Ï´Ù. 802.1Q Åͳθµ ±â´ÉÀº ¼ºñ½º Á¦°ø ¾÷ü
µéÀÌ ´ÜÀÏ VLAN(ÃÖ´ë 4,096°³ÀÇ VLAN ID)À» ÀÌ¿ëÇÏ¿© ¿©·¯ °³ÀÇ VLANÀ» °®°í ÀÖ´Â °í°´À» Áö¿øÇÒ ¼ö
ÀÖ½À´Ï´Ù. ÀÌ ±â´ÉÀº ¶ÇÇÑ °í°´ÀÌ µ¿ÀÏÇÑ VLAN IDÀ» »ç¿ëÇÏ´Â °æ¿ì¿¡µµ ¼ºñ½º Á¦°ø¾÷ü ÀÎÇÁ¶ó ³»¿¡¼
°í°´ÀÇ º»·¡ VLAN ID¸¦ À¯ÁöÇÏ°í ¼·Î ´Ù¸¥ °í°´µé¿¡°Ô¼ Æ®·¡ÇÈÀ» ºÐ¸®ÇÕ´Ï´Ù. °á°úÀûÀ¸·Î TLS¸¦ ÀÌ
¿ëÇÏ´Â ±â¾÷ °í°´µéÀº µ¿ÀÏÇÑ ±â¾÷ LAN¿¡ ÀÖ´Â Àå¼Ò¶ó°í Çصµ ´Ù¸¥ ¸ÞÆ®·Î Àå¼Ò¿¡¼ ¼ºñ½º Á¦°ø¾÷ü±î
Áö Æ®·¡ÇÈÀ» º¸ÀÌÁö ¾Ê°Ô Àü¼ÛÇÏ°í ¼ö½ÅÇÒ ¼ö ÀÖ½À´Ï´Ù.
Layer 2 VPN ¼ºñ½º »Ó¸¸ ¾Æ´Ï¶ó Cisco Catalyst 3550¿¡ ´ëÇÑ VRF-lite(Virtual Routing Forwarding-
lite) ¹× BGP(Border Gateway Protocol)ÀÇ ÇâÈÄ ¼ÒÇÁÆ®¿þ¾î Áö¿øÀº °³º° ¶ó¿ìÆà Å×À̺íÀ» VPN °í°´¸¶
´Ù À¯ÁöÇØ Layer 3 VPN ¼ºñ½º¸¦ °¡´ÉÇÏ°Ô ÇÒ °ÍÀÔ´Ï´Ù.
Cisco Catalyst 3550Àº ¶Ù¾î³ Layer 3 ¼¼ºÐÈ QoS ±â´ÉÀ» Á¦°øÇÏ¿© ¼ºñ½º Á¦°ø ¾÷üµéÀÌ °íÇ°Áú ¼ºñ
½º¿¡ SLA(Service-Level Agreement)¸¦ Á¦°øÇÒ ¼ö ÀÖ°Ô ÇØ ÁÝ´Ï´Ù. ÀÌ·¯ÇÑ QoS ±â´ÉÀº ÃÖÀûÀÇ ¹æ¹ýÀ¸
·Î ³×Æ®¿öÅ© Æ®·¡ÇÈÀÇ ºÐ·ù ¹× ¿ì¼± ¼øÀ§¸¦ ÁöÁ¤ÇÒ »Ó¸¸ ¾Æ´Ï¶ó, ÆøÁÖ Çö»óÀ» ¹æÁöÇÒ ¼ö ÀÖ°Ô ÇØ ÁÝ´Ï´Ù.
Cisco Catalyst 3550Àº ÆÐŶÀÌ °øÀ¯ ¹öÆÛ¿¡ À§Ä¡Çϱâ Àü¿¡ À¯ÀÔ ÆÐŶÀ» ºÐ·ù, ÀçºÐ·ù, Æú¸®½Ì ¹× ¸¶Å·ÇÒ
¼ö ÀÖ½À´Ï´Ù. ÆÐŶ ºÐ·ù ±â´ÉÀº ´Ù¾çÇÑ Æ®·¡ÇÈ ÇÃ·Î¿ì »çÀÌ¿¡¼ ³×Æ®¿öÅ© ¿ä¼Ò¸¦ ±¸º°ÇÒ ¼ö ÀÖ°Ô ÇØ ÁÖ
¸ç, Layer2¿Í 3 QoS Çʵ带 ±â¹ÝÀ¸·Î ÇÏ´Â Á¤Ã¥µéÀ» ½ÇÇàÇÕ´Ï´Ù.
Cisco Catalyst 3550 ½ºÀ§Ä¡´Â QoS¸¦ ±¸ÇöÇϱâ À§ÇØ ¸ÕÀú Æ®·¡ÇÈ Ç÷ο쳪 ÆÐŶ ±×·ìÀ» ½Äº°ÇÏ°í
DSCP(Differentiated Services Code Point) Çʵ峪 802.1p CoS(class-of-service) ÇÊµå ¶Ç´Â ÀÌ µÑÀ»
¸ðµÎ ÀÌ¿ëÇØ ÀÌ·¯ÇÑ ±×·ìµéÀ» ºÐ·ù ¶Ç´Â ÀçºÐ·ùÇÕ´Ï´Ù . ºÐ·ù ¹× ÀçºÐ·ù´Â ¹ß½ÅÁö/¼ö½ÅÁö IP ÁÖ¼Ò, ¹ß½Å
Áö/¼ö½ÅÁö MAC(Media Access Control) ÁÖ¼Ò ¶Ç´Â Layer 4 TCP/UDP(Transmission Control
Protocol/User Datagram Protocol) Æ÷Ʈó·³ ±¸Ã¼ÀûÀÎ ±âÁØÀ» ±Ù°Å·Î ÀÌ·ç¾îÁý´Ï´Ù. Cisco Catalyst
3550Àº ¶ÇÇÑ ¼ö½Å ½Ã ÆÐŶÀÇ Æú¸®½Ì°ú ¸¶Å·µµ ¼öÇàÇÕ´Ï´Ù. Æú¸®½Ì ¹× ¸¶Å·À» ÆÐŶº° ±âÁØÀ¸·Î ÀûÀýÈ÷ ¼ö
ÇàÇϱâ À§ÇØ ¸ðµç Æ÷Æ®¿¡ Á¦¾î Ç÷¹ÀÎ ¹× µ¥ÀÌÅÍ Ç÷¹ÀÎ ACL(Access Control List)ÀÌ Áö¿øµË´Ï´Ù.
ÆÐŶÀº ºÐ·ù¿Í Æú¸®½Ì ¹× ¸¶Å· ÀýÂ÷¸¦ °ÅÄ£ ´ÙÀ½, ÀûÇÕÇÑ Å¥¿¡ ÁöÁ¤µÇ¾ú´Ù°¡ ½ºÀ§Ä¡¸¦ ºüÁ®³ª°¡°Ô µË´Ï
´Ù. Cisco Catalyst 3550 Series´Â Æ÷Æ® ´ç 4°³ÀÇ ¼Û½Å(¹ß½Å Æ÷Æ®) Å¥¸¦ Áö¿øÇϹǷÎ, ¼ºñ½º Á¦°ø ¾÷üµé
Àº ´Ù¾çÇÑ ¾ÖÇø®ÄÉÀ̼ÇÀ» À§ÇØ ´õ ¼¼¹ÐÇÏ°Ô ºÐ·ùÇÏ°í ´õ ±¸Ã¼ÀûÀ¸·Î ¿ì¼± ¼øÀ§¸¦ ÁöÁ¤ÇÒ ¼ö ÀÖ½À´Ï´Ù.
ÀÌ ½ºÀ§Ä¡´Â ¼Û½Å ½Ã ½ºÄÉÁÙ¸µ ¹× ÆøÁÖ Á¦¾î ±â´ÉÀ» ¼öÇàÇÕ´Ï´Ù. ½ºÄÉÁÙ¸µÀº Å¥°¡ 󸮵Ǵ ¼ø¼¸¦ °áÁ¤
ÇÏ´Â ¾Ë°í¸®ÁòÀÔ´Ï´Ù. ÀÌ ½ºÀ§Ä¡´Â WRR(Weighted Round Robin) ½ºÄÉÁÙ¸µ ¹× ¾ö°ÝÇÑ ¿ì¼± ¼øÀ§ Å¥À×À»
Áö¿øÇÕ´Ï´Ù. WRR Å¥À× ¾Ë°í¸®ÁòÀº ³·Àº ¿ì¼± ¼øÀ§ ÆÐŶµéÀÌ ±Ø½ÉÇÑ ´ë¿ªÆø ºÎÁ·À» °ÞÁö ¾Êµµ·Ï ÇÏ°í, ³×
Æ®¿öÅ© °ü¸®ÀÚ°¡ °ü¸®ÇÏ´Â ¿ì¼± ¼øÀ§¿¡ ¿µÇâÀ» ÁÖÁö ¾ÊÀ¸¸é¼ ¼ºñ½º¸¦ Á¦°ø¹Þµµ·Ï º¸ÀåÇÕ´Ï´Ù. ¾ö°ÝÇÑ
¿ì¼± ¼øÀ§ ½ºÄÉÁÙ¸µÀº ÃÖ¿ì¼± ¼øÀ§ ÆÐŶÀÌ Ç×»ó ´Ù¸¥ ¸ðµç Æ®·¡ÇÈ¿¡ ¿ì¼±ÇÏ¿© ¼ºñ½º¸¦ ¹ÞÀ» ¼ö ÀÖµµ·Ï
ÇØ ÁÝ´Ï´Ù. Cisco Catalyst 3550 Series ±â°¡ºñÆ® ÀÌ´õ³Ý Æ÷Æ®´Â ½ºÄÉÁÙ¸µ ±â´É°ú ¿¬°èÇÏ¿© WRED
(Weighted Random Early Detection)À» ÅëÇØ ÆøÁÖ Çö»ó Á¦¾î¸¦ Áö¿øÇÕ´Ï´Ù. WRED´Â ÆøÁÖ Çö»óÀÌ ¹ß»ý
Çϱâ Àü¿¡ ÆÐŶÀÌ µå·ÓµÇ´Â ÇÑ°è°ªÀ» ¼³Á¤ÇÔÀ¸·Î½á ÀÌ·¯ÇÑ ÆøÁÖ Çö»óÀ» ¹æÁöÇÕ´Ï´Ù.
Cisco Catalyst 3550´Â CIR(Committed Information Rate) ±â´É Áö¿øÀ» ÅëÇØ ¼Óµµ Á¦ÇÑÀ» ¼öÇàÇÒ ¼ö ÀÖ
½À´Ï´Ù. CIRÀ» ÅëÇÏ¸é ´ë¿ªÆøÀº 8 Kbps Á¤µµ·Î ³·Àº Áõ°¡·®À» º¸Àå ¹ÞÀ» ¼ö ÀÖ½À´Ï´Ù. ´ë¿ªÆø ÇÒ´çÀº
MAC ¹ß½ÅÁö ÁÖ¼Ò, MAC ¼ö½ÅÁö ÁÖ¼Ò, IP ¹ß½ÅÁö ÁÖ¼Ò, IP ¼ö½ÅÁö ÁÖ¼Ò ¹× TCP/UDP Æ÷Æ® ¹øÈ£¸¦ ºñ·ÔÇØ
¿©·¯ °¡Áö ±âÁØÀ» ±Ù°Å·Î ÀÌ·ç¾îÁú ¼ö ÀÖ½À´Ï´Ù. ÇâÈÄ Ãâ½ÃµÇ´Â ¼ÒÇÁÆ®¿þ¾î¿¡¼´Â ¼ö½Å ½Ã VALNº°, Æ÷
Æ®º° Æú¸®½Ì(Policing)ÀÌ Áö¿øµÉ ¿¹Á¤ÀÔ´Ï´Ù. Cisco Catalyst 3550 SeriesÀÇ °¢ 10/100 Æ÷Æ®´Â 8°³ÀÇ Áý
ÇÕ ¶Ç´Â °³º° ¼ö½Å Æú¸®¼¿Í 8°³ÀÇ ÁýÁß ¼Û½Å Æú¸®¼¸¦ Áö¿øÇÕ´Ï´Ù. Cisco Catalyst 3550 SeriesÀÇ °¢ ±â
°¡ºñÆ® ÀÌ´õ³Ý Æ÷Æ®´Â 128°³ÀÇ ÁýÁß ¶Ç´Â °³º° ¼ö½Å Æú¸®¼¿Í 8°³ÀÇ ÁýÁß ¼Û½Å Æú¸®¼¸¦ Áö¿øÇÕ´Ï´Ù. ÀÌ
·¯ÇÑ ¼º´ÉÀ¸·Î ¼ºñ½º Á¦°ø¾÷ü´Â º¸´Ù ¼¼ºÐÈµÈ ¼ºñ½º¸¦ Á¦°øÇϱâ À§ÇØ À¯¿¬¼ºÀ» È®º¸ÇÒ ¼ö ÀÖ½À´Ï´Ù.
ÀÌ¿Ü¿¡µµ Cisco Catalyst 3550 Series´Â OSPF(Open Shortest Path First), IGRP(Interior Gateway
Routing Protocol), EIRGP(Enhanced IGRP), BGP(Border Gateway Protocol)(ÇâÈÄ ¼ÒÇÁÆ®¿þ¾î Ãâ½Ã
¿¹Á¤), RIP(Routing Information Protocol) ¹× EMI¸¦ °®Ãá RIP v2, PIM(Protocol-Independent
Multicast) ±×¸®°í ¸ÖƼij½ºÆ® ¾ÖÇø®ÄÉÀ̼ÇÀ» À§ÇÑ Çϵå¿þ¾î ±â¹ÝÀÇ IGMP ½º´©ÇÎ °°Àº Çϵå¿þ¾î ±â¹Ý
ÀÇ °í¼º´É IP ¶ó¿ìÆÃÀ» Áö¿øÇÕ´Ï´Ù. Cisco Catalyst 3550 Series´Â VoIP¸¦ À§ÇØ À½¼º VLANÀ» Áö¿øÇÕ´Ï
´Ù. ¼ºñ½º Á¦°ø ¾÷üµéÀº ¾Õ¼ ¾ð±ÞÇÑ ¶Ù¾î³ QoS ¹× ¼Óµµ Á¦ÇÑ ±â´É°ú ÇÔ²² À½¼º, ºñµð¿À ¹× µ¥ÀÌÅÍ ¼
ºñ½º¸¦ ¸ðµÎ ÇϳªÀÇ ³×Æ®¿öÅ© ¾ÆÅ°ÅØó¿¡ Á¦°øÇÏ´Â Cisco Catalyst 3550 Series¸¦ ÀÌ¿ëÇÏ¿© À¯¿¬ÇÑ ³×Æ®
¿öÅ©¸¦ ±¸ÃàÇÒ ¼ö ÀÖ½À´Ï´Ù.
º¹¿ø·Â Çâ»ó ¹× ³×Æ®¿öÅ© ¸®´ø´ø½Ã¸¦ ÅëÇÑ ¼ºñ½ºÀÇ °¡¿ë¼º
Cisco Catalyst 3550 Series´Â dzºÎÇÑ º¹¿ø·Â Çâ»ó ±â´ÉÀ» Á¦°ø, Àå¾Ö º¹±¸¸¦ ½Å¼ÓÇÏ°Ô Ã³¸®ÇÏ¿© °¡¿ë¼º
ÀÌ ³ôÀº ³×Æ®¿öÅ©¸¦ ±¸ÃàÇÒ ¼ö ÀÖ°Ô ÇØÁÝ´Ï´Ù. IEEE 802.1w RST(Rapid Spanning Tree) Ç¥ÁØ Ã¤ÅÃÀ¸·Î
¼ºñ½º Á¦°ø ¾÷üµéÀº ³×Æ®¿öÅ©ÀÇ ¾ÈÁ¤¼º°ú ½Å·Úµµ¸¦ ±Ø´ëÈÇÒ ¼ö ÀÖ´Â ¼ºê¼¼ÄÁµå ½ºÆÐ´× Æ®¸® ÄÁ¹öÀü
½º ½Ã°£À» ¾òÀ» ¼ö ÀÖ½À´Ï´Ù. IEEE 802.1s MST(Multiple Spanning Tree) Ç¥ÁØÀ» 802.1w Ç¥ÁØ°ú ¿¬°èÇÏ
¿© ¹èÄ¡Çϸé VLANÀ» ½ºÆÐ´× Æ®¸® ÀνºÅϽº·Î ºÐ·ùÇÏ¿© STPÀÇ È®À强À» Çâ»ó½Ãų »Ó¸¸ ¾Æ´Ï¶ó, 802.1D
STP¸¦ ½ÇÇàÇÏ´Â ÀåÄ¡µé °£ÀÇ ¿ª¹æÇâ ȣȯ¼ºÀ» Á¦°øÇÒ ¼öµµ ÀÖ½À´Ï´Ù.
¶ÇÇÑ ¼ºñ½º Á¦°ø ¾÷üµéÀº BPDU(Bridge Protocol Data Unit) º¸È£ ¹× STRG(Spanning Tree Root
Guard)¸¦ ±¸ÇöÇÏ¿© ³×Æ®¿öÅ©ÀÇ ½Å·Úµµ¸¦ Çâ»ó½Ãų ¼ö ÀÖ½À´Ï´Ù. BPDU º¸È£ ÀåÄ¡´Â ¼ºñ½º Á¦°ø ¾÷üµé
ÀÌ STP PortFast¸¦ »ç¿ëÇÒ ¼ö ÀÖ´Â ÀÎÅÍÆäÀ̽º¸¦ Áß´ÜÇÏ¿© °í°´ÀÇ ³×Æ®¿öÅ©¿¡¼ BPDU¸¦ ¼ö½ÅÇÏÁö ¸øÇÏ
°Ô Çϸç STRG´Â ¼ºñ½º Á¦°ø¾÷ü ³×Æ®¿öÅ© ¹Û¿¡ ÀÖ´Â °í°´ÀÇ ÀåÄ¡°¡ STP ·çÆ® ³ëµå°¡ µÇ´Â °ÍÀ» ¸·¾Æ
ÁÝ´Ï´Ù.
Cisco Catalyst 3550 Series´Â ¼ºñ½º Á¦°ø ¾÷üµéÀÌ Áߺ¹¼ºÀÌ ³ôÀº ³×Æ®¿öÅ©¸¦ ±¸ÃàÇÒ ¼ö ÀÖ°Ô ÇØ ÁÝ´Ï
´Ù. PVST+´Â Áߺ¹ ¸µÅ©¿¡ Layer 2 ·Îµå °øÀ¯¸¦ ±¸ÇöÇÏ¿© Áߺ¹ ¼³°èÀÇ °íÀ¯ÇÑ Ãß°¡ ¿ë·®À» È¿À²ÀûÀ¸·Î
È°¿ëÇÒ ¼ö ÀÖ°Ô ÇÕ´Ï´Ù. Cisco HSRP(Hot Standby Router Protocol)´Â Layer 3 ³×Æ®¿öÅ©¸¦ À§ÇØ Áߺ¹ Àå
¾Ö º¹±¸ ¶ó¿ìÆà ÅäÆú·ÎÁö¸¦ »ý¼ºÇϸç, µ¿ÀÏ ºñ¿ëÀÇ ¶ó¿ìÆÃÀº Layer 3 ·Îµå ¹ë·±½Ì ¹× ¸®´ø´ø½Ã¸¦ Á¦°øÇÕ
´Ï´Ù. ¼ºñ½º Á¦°ø ¾÷üµéÀº ¶ÇÇÑ Cisco EtherChannel¢ç±â¼úÀ» ÀÌ¿ëÇÏ¿© ±â°¡ºñÆ® EtherChannelÀ» Åë
Çؼ´Â 16 Gbps±îÁö, °í¼Ó EtherChannelÀ» ÅëÇؼ´Â 1.6 Gbps±îÁö ÁýÁßÇÒ ¼ö ÀÖ½À´Ï´Ù. ÀÌ·¯ÇÑ
EtherChannel ±â¼úÀº ³»°áÇÔ¼ºÀ» Çâ»ó½ÃÄÑÁÖ°í ½ºÀ§Ä¡µé »çÀÌ¿¡ ¶Ç´Â ¶ó¿ìÅÍ¿¡ º¸´Ù ³ôÀº ¼ÓµµÀÇ ÁýÁß
´ë¿ªÆøÀ» Á¦°øÇÕ´Ï´Ù.
Cisco Catalyst 3550 Series´Â º¹¿ø·Â ¹× ³×Æ®¿öÅ© ¸®´ø´ø½Ã ÀÌÁ¡ ¿Ü¿¡µµ CWDM GBIC ¼Ö·ç¼Ç Áö¿øÀ»
ÅëÇØ ¾×¼¼½º ¿¡Áö¿¡¼ÀÇ ¸ÞÆ®·Î ³×Æ®¿öÅ© È®À强À» ½ÇÇöÇÒ ¼ö ÀÖ½À´Ï´Ù. ÀÌ ¼Ö·ç¼ÇÀº ¼ºñ½º Á¦°ø ¾÷ü
µéÀÌ ÆÄÀ̹ö¸¦ Ãß°¡ÇÏÁö ¾Ê°íµµ ´ë¿ªÆøÀ» È®ÀåÇÒ ¼ö ÀÖ°Ô ÇØ ÁÝ´Ï´Ù. ¼ºñ½º Á¦°ø¾÷ü´Â ÃÖ´ë 120 kmÀÇ
°Å¸®¿¡¼ ÇÑ ½ÖÀÇ ´ÜÀÏ ¸ðµå ÆÄÀ̹ö¿¡ ´ë¿ªÆøÀ» ÃÖ´ë 8±â°¡ºñÆ®±îÁö È®ÀåÇÒ ¼ö ÀÖ½À´Ï´Ù. ¶ÇÇÑ Cisco
Catalyst 3550 Series¿¡ CWDM GBIC¸¦ Áö¿øÇÏ¸é ¿©·¯ °³ÀÇ Cisco Catalyst 3550 Series ½ºÀ§Ä¡µéÀ» ¸ð
¾Æ ±âÁ¸ÀÇ ÆÄÀ̹ö ÀÎÇÁ¶ó¸¦ ÀÌ¿ëÇØ ½±°Ô ³×Æ®¿öÅ© ´ë¿ªÆøÀ» ¾÷±×·¹À̵åÇÒ ¼ö ÀÖ½À´Ï´Ù.
¸ÞÆ®·Î ³×Æ®¿öÅ©ÀÇ È®À强Àº Cisco Catalyst 3550 SeriesÀÇ 4,096°³ÀÇ VLAN ID ¹× 1,005°³ÀÇ ½ºÀ§Ä¡º°
È°¼º VLANÀ» ÅëÇؼµµ Çâ»óµË´Ï´Ù. VALN Æ®··Å©´Â Ç¥ÁØ ±â¹ÝÀÇ 802.1Q ¶Ç´Â ISL(Inter-Switch Link)
VLAN Æ®··Å· ¾ÆÅ°ÅØó¸¦ »ç¿ëÇÏ´Â ¸ðµç Æ÷Æ®¿¡¼ »ý¼ºµÉ ¼ö ÀÖ½À´Ï´Ù.
ACL(Access Control List) ¹× Çâ»óµÈ º¸¾È ±â´ÉÀ» ÅëÇÑ ¼ºñ½º º¸¾È
Cisco Catalyst 3550 Series´Â ACL(Access Control List)À» ÀÌ¿ëÇÏ¿© °í±Þ µ¥ÀÌÅÍ º¸¾ÈÀ» Á¦°øÇÕ´Ï´Ù.
¹ß½ÅÁö ¹× ¼ö½ÅÁö MAC ÁÖ¼Ò, IP ÁÖ¼Ò ¶Ç´Â TCP/UDP Æ÷Æ®¿¡ ±Ù°ÅÇÏ¿© ÆÐŶÀ» °ÅºÎÇÔÀ¸·Î½á, »ç¿ëÀÚµé
Àº ³×Æ®¿öÅ©ÀÇ ¹Î°¨ÇÑ ºÎºÐ¿¡ ´ëÇÑ Á¢±ÙÀÌ Á¦Çѵ˴ϴÙ. ¶ÇÇÑ ¸ðµç ACL ·è¾÷ÀÌ Çϵå¿þ¾î¿¡¼ ÀÌ·ç¾îÁö¹Ç
·Î ³×Æ®¿öÅ©¿¡ ACL ±â¹Ý º¸¾ÈÀ» ±¸ÇöÇÒ ¶§ Àü¼Û ´É·ÂÀÌ ÀúÇϵÇÁö ¾Ê½À´Ï´Ù. Cisco Catalyst 3550 Series
´Â ¶Ù¾î³ º¸¾È °ü¸®¸¦ À§ÇØ VALN, Layer 3´Â ¹°·Ð Layer 2 ÀÎÅÍÆäÀ̽º¿¡µµ Ç¥ÁØ ¹× È®ÀåµÈ ACLÀ» Áö
¿øÇÕ´Ï´Ù.
¼ºñ½º Á¦°ø ¾÷üµéÀº ¶ÇÇÑ »ç¼³ VLAN ¿¡Áö¸¦ »ç¿ëÇÏ¿© ÇÑÃþ ³ôÀº ¼öÁØÀÇ µ¥ÀÌÅÍ º¸¾ÈÀ» ±¸ÇöÇÒ ¼ö ÀÖ
½À´Ï´Ù. ÀÌ ±â´ÉÀº ½ºÀ§Ä¡ÀÇ Æ÷Æ®µé °£¿¡ º¸¾È°ú °Ý¸®¸¦ Á¦°øÇÔÀ¸·Î½á, Æ®·¡ÇÈÀÌ Á÷Á¢ ÀÔ·ÂÁ¡¿¡¼ °¡»ó
°æ·Î¸¦ ÅëÇØ ÁýÇÕ ÀåÄ¡·Î À̵¿ÇÏ°í ´Ù¸¥ Æ÷Æ®·Î´Â ¹æÇâÀÌ ÁöÁ¤µÉ ¼ö ¾øµµ·Ï º¸ÀåÇÕ´Ï´Ù. Local Proxy
ARP(Address Resolution Protocol)´Â »ç¼³ VLAN ¿¡Áö¿Í °áÇÕµÇ¾î ºê·Îµåij½ºÆ®¸¦ ÃÖ¼ÒÈÇÏ°í °¡¿ë ´ë
¿ªÆøÀ» ±Ø´ëÈÇÕ´Ï´Ù.
¼ºñ½º Á¦°ø ¾÷üµéÀº ÀÌ·¯ÇÑ Cisco Catalyst 3550 Series¸¦ È°¿ëÇÏ¿© ³ôÀº ¼öÁØÀÇ º¸¾È ÄܼÖÀ» ±¸ÇöÇÒ
¼ö ÀÖ½À´Ï´Ù. ½ºÀ§Ä¡ Äְܼú À¥ ±â¹Ý °ü¸® ÀÎÅÍÆäÀ̽º¿¡¼ÀÇ ¸ÖƼ·¹º§ ¾×¼¼½º º¸¾ÈÀº ±ÇÇÑÀÌ ¾ø´Â »ç¿ë
ÀÚµéÀÌ ½ºÀ§Ä¡ ±¸¼º¿¡ Á¢±ÙÇϰųª º¯°æÇÒ ¼ö ¾øµµ·Ï ÇÕ´Ï´Ù. TACACS+(Terminal Access Controller
Access Control System) ¹× RADIUS(Remote Authentication Dial-In User Service) ÀÎÁõÀº ½ºÀ§Ä¡¿¡
´ëÇÑ Áß¾Ó ÁýÁᫎ ¾×¼¼½º Á¦¾î¸¦ °¡´ÉÇÏ°Ô Çϸç Çã°¡ ¹ÞÁö ¾ÊÀº »ç¿ëÀÚµéÀÌ ±¸¼ºÀ» º¯°æÇÏÁö ¸øÇϵµ·Ï
Á¦ÇÑÇÕ´Ï´Ù.
¼ºñ½º Á¦°ø¾÷ü´Â ¶ÇÇÑ °³º° °í°´ ÀÎÁõÀ» À§ÇÑ 802.1x Æ÷Æ® ±â¹Ý ÀÎÁõ, °í°´ È®ÀÎÀ» À§ÇÑ DHCP Option
82 ¸±·¹ÀÌ ±×¸®°í Æ÷Æ®º°·Î Çã¿ëµÈ µ¿½Ã MAC ÁÖ¼Ò¸¦ Á¦ÇÑÇϱâ À§ÇÑ MAC ÁÖ¼Ò ¿¡ÀÌ¡À» °®Ãá Æ÷Æ® º¸
¾ÈÀ» Ãß°¡ÇÏ¿© ³×Æ®¿öÅ©ÀÇ º¸¾ÈÀ» Çâ»ó½Ãų ¼ö ÀÖ½À´Ï´Ù.
Service Management through IE 2100 and SNMP
Cisco Catalyst 3550 Series´Â IE 2100 Series Intelligence Engine Áö¿ø ¹× SNMP(Simple Network
Management Protocol)À» ÅëÇØ ¶Ù¾î³ ¼ºñ½º °ü¸® ¼º´ÉÀ» Á¦°øÇÕ´Ï´Ù. ¼ºñ½º Á¦°ø¾÷üµéÀº ÀڽŵéÀÇ
OSS(Operations Support System)¿¡ Catalyst 2950 Series¸¦ ¸Å²ô·´°Ô ÅëÇÕÇÒ ¼ö ÀÖ¾î ÇÃ·Î¿ì ¾²·ç ÇÁ
·ÎºñÀú´×(Flow-Through Provisioning)À» Çâ»ó½Ãų ¼ö ÀÖ½À´Ï´Ù.
¼ºñ½º Á¦°ø ¾÷üµéÀÌ IE 2100 Series ³×Æ®¿öÅ© ÀåÄ¡¸¦ ÀÌ¿ëÇϸé Cisco Catalyst 3550 Series¸¦ ºñ·ÔÇÑ
Cisco IOS¢ç ÀåÄ¡µéÀ» È¿À²ÀûÀ¸·Î °ü¸®ÇÒ ¼ö ÀÖ½À´Ï´Ù. IE 2100 Series´Â ÀÛ¾÷ ÁöÇâÇü GUI(graphical
user interface), ÇÁ·Î±×·¡¸Óºí XML(extensible markup language), ±¸¼º ÅÛÇø´ °ü¸® ¹× ³»ÀåÇü ¸®Æ÷Áö
Å丮°¡ µé¾î ÀÖ´Â ¿ÏÀüÇÑ ÀÚ±ÞÇü ÀåÄ¡ÀÔ´Ï´Ù.
³×Æ®¿öÅ© °ü¸®ÀÚ´Â À¥ GUI¸¦ ÀÌ¿ëÇÏ¿© ±âÁ¸ IOS CLI(Command-Line Interface) ±¸¼º ÆÄÀÏÀ» ½Å¼ÓÇÏ°Ô
Àç»ç¿ë °¡´ÉÇÑ ÅÛÇø´À¸·Î ½Å¼ÓÇÏ°Ô ÀüȯÇÒ ¼ö ÀÖ½À´Ï´Ù. Cisco IE 2100 Series´Â ¿ÜºÎ ¸®Æ÷ÁöÅ丮 Áö¿ø
¹× È¿À²ÀûÀÎ ¿öÅ©Ç÷οì·Î Cisco ÀåÄ¡¸¦ ¹èÄ¡ÇÒ ¼ö ÀÖ´Â À̺¥Æ® ±â¹ÝÀÇ Cisco IOS XML ÀÎÅÍÆäÀ̽º¸¦
ÅëÇØ ±âÁ¸ °í°´ OSS³ª BSS(Business Support System) ¿Í ÇÁ·ÎºñÀú´× ½Ã½ºÅÛÀ» °£ÆíÇÏ°Ô ÅëÇÕÇÕ´Ï´Ù.
¼ºñ½º Á¦°ø ¾÷ü´Â ¶ÇÇÑ Á¾ÇÕÀûÀÎ ´ë¿ª ³» °ü¸®¸¦ À§ÇØ SNMP ¹öÀü 2 ¹× 3(ÇâÈÄ ¼ÒÇÁÆ®¿þ¾î Ãâ½Ã ¿¹Á¤)
°ú ÅÚ³Ý ÀÎÅÍÆäÀ̽º¸¦ ÀÌ¿ëÇÏ¿© Cisco Catalyst 3550À» °ü¸®ÇÒ ¼ö ÀÖ½À´Ï´Ù. CLI ±â¹ÝÀÇ °ü¸® ÄܼÖÀº ¼¼
ºÎÀûÀÎ ´ë¿ª ¿Ü °ü¸®¸¦ Á¦°øÇÕ´Ï´Ù.
´Ù¾çÇÑ ºô¸µ ¹æ½ÄÀ» À§ÇØ Catalyst 2950 Series¿¡ ´ëÇÑ Æ®·¡ÇÈ Á¤º¸¸¦ ¼öÁýÇϱâ À§ÇØ ¼ºñ½º Á¦°ø¾÷ü¿¡
°Ô Á¾ÇÕÀûÀÎ MIB(Management Information Base)°¡ Á¦°øµË´Ï´Ù.
Á¦Ç° ±â´É ¹× ÀÌÁ¡
±â´É
ÀÌÁ¡
¼ºñ½º Æø
Layer 2 ¹× Layer 3
VPN ¼ºñ½º
802.1Q ÅͳθµÀº VLAN-in-VLAN °èÃþ±¸Á¶¸¦ ÀÌ¿ëÇÏ°í, űëµÈ ÆÐŶÀ»
űëÇÏ¿© VLAN °ø°£À» È®ÀåÇÕ´Ï´Ù. 802.1Q Åͳθµ ±â´ÉÀº ¼ºñ½º Á¦°ø
¾÷üµéÀÌ ´ÜÀÏ VLANÀ» ÀÌ¿ëÇÏ¿© VALNÀÌ ¿©·¯ °³ÀÎ °í°´À» Áö¿øÇÏ´Â µ¿
½Ã¿¡ °í°´ÀÌ µ¿ÀÏÇÑ VLAN¿¡ ³ªÅ¸³ªµµ ¼ºñ½º Á¦°ø ¾÷üÀÇ ÀÎÇÁ¶ó ³»¿¡¼
°í°´ÀÇ VLAN ID¸¦ À¯ÁöÇÏ°í ¼·Î ´Ù¸¥ °í°´µé·ÎºÎÅÍ Æ®·¡ÇÈÀ» ºÐ¸®ÇÒ ¼ö
ÀÖ°Ô ÇØ ÁÝ´Ï´Ù.
VRF-lite(ÇâÈÄ ¼ÒÇÁÆ®¿þ¾î Áö¿ø ¿¹Á¤)´Â Çϳª ÀÌ»óÀÇ Layer 3 ÀÎÅÍÆäÀÌ
½º¸¦ °¢°¢ÀÇ VRF¿Í ¿¬°ü½ÃÄÑ ´ÜÀÏ Cisco Catalyst 3550 Series¿¡ ¿©·¯ °³
ÀÇ Layer 3 VPNÀ» »ý¼ºÇÔÀ¸·Î½á °¡»ó ÆÐŶ Àü¼Û Å×À̺íÀ» ±¸¼ºÇÕ´Ï´Ù.
VRFÀÇ ÀÎÅÍÆäÀ̽º´Â ÀÌ´õ³Ý Æ÷Æ®¿¡¼´Â ¹°¸®ÀûÀÌ°í VLAN SVI(switch
virtual interface)¿¡¼´Â ³í¸®ÀûÀÏ ¼ö ÀÖ½À´Ï´Ù.
À½¼º ¹× ºñµð¿À ¼ºñ½º
³×Æ®¿öÅ© ³»¿¡¼ÀÇ IP ¸ÖƼij½ºÆ® ¶ó¿ìÆÃÀ» À§ÇÑ PIM(Protocol-
Independent Multicast)Àº ³×Æ®¿öÅ©°¡ ¿äûÇÑ ¸ÖƼij½ºÆ® °ø±Þ(feed)À»
¼ö½ÅÇÒ ¼ö ÀÖ°Ô ÇØ ÁÖ¸ç, ½ºÀ§Ä¡°¡ ÇÁ·ç´×(Pruning)µÉ ¸ÖƼij½ºÆ®¿¡ Âü¿©
ÇÏÁö ¾Êµµ·Ï ÇØ ÁÝ´Ï´Ù(PIM-SM(PIM Àú¹Ðµµ ¸ðµå), PIM-DM(PIM °í¹Ðµµ
¸ðµå) ¹× PIM-Àú¹Ðµµ/°í¹Ðµµ ¸ðµå Áö¿ø).
DVMRP(Distance Vector Multicast Routing Protocol) ÅͳθµÀº ºñ¸Ö
Ƽij½ºÆ® ³×Æ®¿öÅ©¿¡¼ ¸ÖƼij½ºÆ®¸¦ »ç¿ëÇÒ ¼ö ÀÖ´Â µÎ °³ÀÇ ³×Æ®¿öÅ©¸¦
»óÈ£¿¬°áÇØ ÁÝ´Ï´Ù.
IGMP ÇÊÅ͸µÀº ½ºÀ§Ä¡ Æ÷Æ®ÀÇ »ç¿ëÀÚ°¡ ¼Ò¼ÓµÉ ¼ö ÀÖ´Â ¸ÖƼij½ºÆ® ±×
·ì¿¡ ´ëÇÑ Á¦¾î ±â´ÉÀ» Á¦°øÇÕ´Ï´Ù.
VoIP ¾ÖÇø®ÄÉÀ̼ÇÀ» À§ÇÑ À½¼º VLANÀÇ Áö¿øÀ¸·Î µ¿ÀÏÇÑ ¹°¸®Àû Æ÷Æ®
¿¡ µ¥ÀÌÅÍ ¹× À½¼º VLANÀ» »ý¼ºÇÒ ¼ö ÀÖ½À´Ï´Ù.
CGMP(Cisco Group Management Protocol) ¼¹ö ±â´ÉÀº ÇϳªÀÇ ½º
À§Ä¡°¡ EMI¸¦ ÇÊ¿ä·Î ÇÏ´Â ¿©·¯ CGMP Ŭ¶óÀ̾ðÆ® ½ºÀ§Ä¡µéÀ» À§ÇØ
CGMP ¶ó¿ìÅÍ·Î ¼ºñ½º¸¦ Á¦°øÇÒ ¼ö ÀÖ°Ô ÇÕ´Ï´Ù.
IGMP ½º´©ÇÎÀº ¸ÖƼij½ºÆ® ½ºÆ®¸²¿¡ ´ëÇØ Å¬¶óÀ̾ðÆ®°¡ ½Å¼ÓÇÏ°Ô 벐
¡À? ¹× 벯»Å?ÇÒ ¼ö ÀÖ°Ô ÇØ ÁÖ¸ç, ´ë¿ªÆø¿¡ ¹Î°¨ÇÑ ºñµð¿À Æ®·¡ÇÈÀ» ¿äûÀÚ
¿¡°Ô·Î¸¸ Á¦ÇÑÇÕ´Ï´Ù.
°í±Þ QoS
ÆÐŶº° ±âÁØÀ¸·Î ¸¶Å· ¹× ÀçºÐ·ù¸¦ ÅëÇÑ 802.1p CoS ¹× DSCP ÇʵåÀÇ
ºÐ·ù´Â ¹ß½ÅÁö/¼ö½ÅÁö IP ÁÖ¼Ò, ¹ß½ÅÁö/¼ö½ÅÁö MAC ÁÖ¼Ò ¶Ç´Â Layer4
TCP/UDP Æ÷Æ® ¹øÈ£¸¦ »ç¿ëÇÕ´Ï´Ù.
¸ðµç Æ÷Æ® »ó¿¡¼ÀÇ Cisco Á¦¾î Ç÷¹ÀÎ ¹× µ¥ÀÌÅÍ Ç÷¹ÀÎ QoS ACLÀº
ÆÐŶº° ±âÁØ¿¡ µû¶ó ÀûÀýÇÑ ¸¶Å·À» º¸ÀåÇÕ´Ï´Ù.
Çϵå¿þ¾î¿¡ Áö¿øµÇ´Â Æ÷Æ®º° 4°³ÀÇ ¼Û½Å Å¥´Â Æ®·¡ÇÈ À¯ÇüÀ» 4°³±îÁö
Â÷º°ÈÇÏ¿© °ü¸®ÇÒ ¼ö ÀÖ½À´Ï´Ù.
WRR(Weighted Round Robin) ½ºÄÉÁÙ¸µÀº ¼Û½Å Å¥¸¦ Áö´ÉÀûÀ¸·Î Áö¿ø
ÇÏ¿© ÆÐŶ È帧¿¡ ´ëÇØ Â÷º°ÀûÀ¸·Î ¿ì¼± ¼øÀ§¸¦ ÁöÁ¤ÇÒ ¼ö ÀÖ½À´Ï´Ù.
¸ðµç ±â°¡ºñÆ® ÀÌ´õ³Ý Æ÷Æ®»óÀÇ WRED(Weighted Random Early
Detection)´Â Áß´ÜÀÌ ¹ß»ýÇϱâ Àü¿¡ ¼Û½Å Å¥¿¡¼ ÆøÁÖ Çö»óÀ» ÇÇÇÒ ¼ö ÀÖ
°Ô ÇØ ÁÝ´Ï´Ù .
¾ö°ÝÇÑ ¿ì¼± ¼øÀ§ Å¥À×Àº °¡Àå ³ôÀº ¿ì¼± ¼øÀ§ÀÇ ÆÐŶÀÌ Ç×»ó ´Ù¸¥ ¸ð
µç Æ®·¡ÇÈ¿¡ ¾Õ¼ 󸮵ǵµ·Ï ÇÕ´Ï´Ù.
°íµµ·Î ¼¼ºÐÈµÈ QoS ±â´ÉÀº ¼º´É¿¡ ÀüÇô ¿µÇâÀ» ¹ÌÄ¡Áö ¾Ê½À´Ï´Ù.
¼¼ºÐÈµÈ ¼Óµµ Á¦ÇÑ
Cisco CIR(Committed Information Rate) ±â´ÉÀº ´ë¿ªÆøÀ» 8 Kbps¾¿
¹Ì¼¼ÇÏ°Ô Áõ°¡½Ãų ¼ö ÀÖ½À´Ï´Ù.
¹ß½ÅÁö/¼ö½ÅÁö IP ÁÖ¼Ò, ¹ß½ÅÁö/¼ö½ÅÁö MAC ÁÖ¼Ò, Layer 4
TCP/UDP Á¤º¸ ¶Ç´Â ÀÌ·¯ÇÑ ÇʵåÀÇ Á¶ÇÕÀ» ±âÁØÀ¸·Î ¼öÇàµÇ´Â ¼Óµµ Á¦ÇÑ. QoS ACL
(IP ACL ¶Ç´Â MAC ACL), Ŭ·¡½º ¸Ê(class map), Æú¸®½Ã ¸Ê(policy
map)À» »ç¿ëÇÕ´Ï´Ù. ¼ö½Å¿¡¼ÀÇ PVLAN(Per VLAN) Æ÷Æ®º° Æú¸®½ÌÀº Çâ
ÈÄ ¼ÒÇÁÆ®¿þ¾î°¡ Ãâ½ÃµÉ ¿¹Á¤ÀÔ´Ï´Ù.
¼ö½Å ¹× ¼Û½Å Æú¸®½ÌÀ» ÅëÇÏ¿© ÃÖÁ¾ ½ºÅ×À̼ÇÀ̳ª ¾÷¸µÅ©¿¡¼ ¾÷½ºÆ®
¸² ¹× ´Ù¿î½ºÆ®¸² ¾çÂÊÀÇ µ¥ÀÌÅÍ È帧À» ºñµ¿±âÀûÀ¸·Î ½±°Ô °ü¸®ÇÏ´Â ±â
´É
°¢ 10/100 Æ÷Æ®¿¡´Â 8°³ÀÇ ÁýÇÕ ¶Ç´Â °³º° ¼ö½Å Æú¸®¼¿Í 8°³ÀÇ ¼Û½Å
Æú¸®¼¸¦ Áö¿øÇÕ´Ï´Ù.
°¢ ±â°¡ºñÆ® ÀÌ´õ³Ý Æ÷Æ®¿¡´Â 128°³ÀÇ ÁýÇÕ ¶Ç´Â °³º° ¼ö½Å Æú¸®¼¿Í 8
°³ÀÇ ÁýÇÕ ¼Û½Å Æú¸®¼¸¦ Áö¿øÇÕ´Ï´Ù.
°í¼º´É IP ¶ó¿ìÆà ¸ðµç IP ¶ó¿ìÆà ±â´ÉÀº EMI
(Enhanced
Multilayer
Software
Image)
¸¦ ÇÊ¿ä·Î ÇÕ´Ï
´Ù.
Çϵå¿þ¾î¿¡¼ ¼öÇàµÇ´Â Cisco Express Forwarding ±â¹Ý ¶ó¿ìÆà ¾ÆÅ°
ÅØóÀÌ¸ç »ó´çÇÑ °í¼º´ÉÀÇ IP ¶ó¿ìÆÃÀ» Á¦°øÇÒ ¼ö ÀÖ½À´Ï´Ù.
·Îµå ¹ë·±½Ì ¹× È®Àå °¡´ÉÇÑ LAN ±¸¼ºÀ» À§ÇØ °øÅëÀûÀ¸·Î ¹èÄ¡µÇ´Â ¸ðµç ¾÷
°è Ç¥ÁØÇü IP À¯´Ïij½ºÆ® ¶ó¿ìÆà ÇÁ·ÎÅäÄÝ(RIPv1, RIPv2, OSPF, IGRP, EIGRP )
ÀÌ Áö¿øµË´Ï´Ù.
³×Æ®¿öÅ© °æ·Î Á¤º¸ÀÇ ¶ó¿ìÆà Å×À̺íÀ» ¼öµ¿À¸·Î ±¸¼ºÇϱâ À§ÇÑ Á¤Àû IP ¶ó¿ì
ÆÃÀÌ Áö¿øµË´Ï´Ù.
¼·Î ´Ù¸¥ AS(Autonomous System)¿¡¼ ¶ó¿ìÅÍµé °£¿¡ ¹èÄ¡ Á¤º¸¸¦ ±³È¯
Çϱâ À§ÇØ eGBP(Exterior BGP)°¡ Áö¿øµË´Ï´Ù. µ¿ÀÏÇÑ AS ³»¿¡ ÀÖ´Â ¶ó¿ìÅ͵é
°£ÀÇ ¹èÄ¡ Á¤º¸¸¦ ±³È¯Çϱâ À§ÇØ iGBP(Interior BGP)°¡ Áö¿øµË´Ï´Ù. (ÇâÈÄ ¼ÒÇÁ
Æ®¿þ¾î Áö¿ø ¿¹Á¤)
µÑ ÀÌ»óÀÇ VLAN »çÀÌ¿¡¼ ¿ÏÀüÇÑ Layer 3 ¶ó¿ìÆÃÀ» À§ÇÑ VLAN °£ IP ¶ó¿ì
ÆÃÀÌ Áö¿øµË´Ï´Ù.
·Îµå ¹ë·±½Ì ¹× Áߺ¹¼ºÀ» À§ÇÑ µ¿ÀÏÇÑ ºñ¿ëÀÇ ¶ó¿ìÆÃÀÌ Áö¿øµË´Ï´Ù.
µÑ ÀÌ»óÀÇ VLAN °£¿¡ ºñ IP Æ®·¡ÇÈÀ» Àü¼ÛÇϱâ À§ÇÑ Æú¹é ºê¸®Â¡(Fallback
Bridging)ÀÌ Áö¿øµË´Ï´Ù.
Áߺ¹ Àå¾Ö ¹æÁö ¶ó¿ìÆà ÅäÆú·ÎÁö¸¦ »ý¼ºÇϱâ À§ÇÑ CiscoÀÇ HSRP°¡ Áö¿øµË
´Ï´Ù.
¼ºñ½º °¡¿ë¼º
º¹¿ø·Â ¹× ½Å·Ú¼º
IEEE 802.1w RSTP(Rapid Spanning Tree Protocol)Àº Æ÷ÀÎÆ® Åõ Æ÷ÀÎÆ®
(point-to-point) ¿ÍÀ̾ÀÇ ÀÌÁ¡À» Àß È°¿ëÇÏ¸ç ½ºÆÐ´× Æ®¸® ½Ã°£°ú´Â º°°³ÀÎ
½ºÆÐ´× Æ®¸®ÀÇ °í¼Ó ÄÁ¹öÀü½º¸¦ Á¦°øÇÕ´Ï´Ù. ½ºÆÐ´× Æ®¸®ÀÇ À籸¼ºÀº 1ÃÊ ¾È¿¡
ÀÌ·ç¾îÁö¸ç, ÀÌ´Â À½¼º ¹× ºñµð¿À °°ÀÌ Áö¿¬¿¡ ¹Î°¨ÇÑ Æ®·¡ÇÈÀ» Àü¼ÛÇÏ´Â ³×Æ®
¿öÅ©¿¡ À־ ¸Å¿ì Áß¿äÇÑ ±â´ÉÀÔ´Ï´Ù.
°í¼Ó ÄÁ¹öÀü½º¸¦ À§ÇØ RSTP¸¦ »ç¿ëÇÏ´Â IEEE 802.1s MSTP(Multiple
Spanning Tree)´Â VLANÀ» ½ºÆÐ´× Æ®¸® ÀνºÅϽº·Î ºÐ·ùÇÒ ¼ö ÀÖÀ¸¸ç, °¢ ÀÎ
½ºÅϽº¿¡´Â ´Ù¸¥ ½ºÆÐ´× Æ®¸® ÀνºÅϽº¿Í´Â º°°³ÀÎ ½ºÆÐ´× Æ®¸® ÅäÆú·ÎÁö°¡
µé¾î ÀÖ½À´Ï´Ù. ÀÌ ¾ÆÅ°ÅØó´Â µ¥ÀÌÅÍ Æ®·¡ÇÈÀ» À§ÇÑ ´ÙÁß Àü¼Û °æ·Î¸¦ Á¦°ø
ÇÏ°í, ·Îµå ¹ë·±½ÌÀ» ½ÇÇöÇÏ¸ç ¸¹Àº ¾çÀÇ VALNÀ» Áö¿øÇϱâ À§ÇØ ½ºÆÐ´× Æ®¸®
ÀνºÅϽºÀÇ ¼ö¸¦ ÁÙ¿©ÁÝ´Ï´Ù.
º¹¿ø·Â ¹× ½Å·Ú¼º
(°è¼Ó)
Cisco UplinkFast/BackboneFast ±â¼úÀº Àå¾Ö º¹±¸¸¦ ½Å¼ÓÇÏ°Ô Ã³¸®ÇÏ¿©
Àü¹ÝÀûÀÎ ³×Æ®¿öÅ©ÀÇ ¾ÈÁ¤¼º ¹× ½Å·Ú¼ºÀ» Çâ»ó½ÃÄÑ ÁÝ´Ï´Ù.
Cisco CSUF(CrossStack UplinkFast) ±â¼úÀº µ¶¸³Çü ½ºÅà ¹éÇ÷¹ÀÎ ´Ü°è
½Ä ±¸¼º¿¡¼ Cisco GigaStack GBIC¸¦ »ç¿ëÇÏ´Â ½ºÀ§Ä¡ ½ºÅÃÀÇ °í¼Ó ½ºÆд×
Æ®¸® ÄÁ¹öÀü½º(2ÃÊ ÀÌÇÏ)¸¦ ÅëÇØ Çâ»óµÈ ¸®´ø´ø½Ã¿Í ³×Æ®¿öÅ© º¹¿ø·ÂÀ» Á¦°ø
ÇÕ´Ï´Ù.
½ºÅÂÅ· ¿¬°áÀ» ÀÌÁßÀ¸·Î ÇÏ¸é µ¶¸³ÀûÀÎ ½ºÅà ¹éÇ÷¹ÀÎ ´Ü°è½Ä ±¸¼º¿¡¼ ÃÖ
»óÇÏ´Ü ½ºÀ§Ä¡¸¦ À§ÇÑ ÀÌÁß ·çÇÁ¹é ¿¬°áÀÌ °¡´ÉÇÕ´Ï´Ù.
BPDU º¸È£´Â BPDU ¼ö½Å ½Ã STP PortFast¸¦ »ç¿ëÇÒ ¼ö ÀÖ´Â ÀÎÅÍÆäÀ̽º
¸¦ Áß´ÜÇÏ¿© ¿ì¹ßÀûÀÎ ½ºÆÐ´× Æ®¸® ÅäÆú·ÎÁöÀÇ º¯°æÀ» ¸·¾ÆÁÝ´Ï´Ù.
STRG´Â ³×Æ®¿öÅ© °ü¸®ÀÚÀÇ ÅëÁ¦ ¹üÀ§¿¡ ÀÖÁö ¾ÊÀº ¿¡Áö ÀåÄ¡µéÀÌ STP ·ç
Æ® ³ëµå°¡ µÇÁö ¾Êµµ·Ï ÇØ ÁÝ´Ï´Ù.
CMS(Cluster Management Suite) ¼ÒÇÁÆ®¿þ¾î¿¡¼ ½ÇÇàµÇ´Â ¸í·É ½ºÀ§Ä¡
¸®´ø´ø½Ã ±â´ÉÀº °í°´µéÀÌ ÁÖ ¸í·É ½ºÀ§Ä¡°¡ °íÀ峯 °æ¿ì Ŭ·¯½ºÅÍ °ü¸® ±â
´ÉÀ» ¶°¸Ã´Â ¹é¾÷ ¸í·É ½ºÀ§Ä¡¸¦ ÁöÁ¤ÇÒ ¼ö ÀÖ°Ô ÇØ ÁÝ´Ï´Ù.
UDLD(Unidirectional Link Detection) ±â´ÉÀº À߸øµÈ ±¤¼¶À¯ ¿ÍÀ̾À̳ª
Æ÷Æ®ÀÇ °áÇÔÀ¸·Î ÀÎÇÑ ±¤¼¶À¯ ÀÎÅÍÆäÀ̽º »óÀÇ ´Ü¹æÇâ ¸µÅ©¸¦ ŽÁöÇÏ¿© À̸¦
»ç¿ëÇÒ ¼ö ¾ø°Ô ÇØ ÁÝ´Ï´Ù.
Æ÷Æ®º° ºê·Îµåij½ºÆ®, ¸ÖƼij½ºÆ® ¹× À¯´Ïij½ºÆ® ÆøÁÖ Á¦¾î´Â Àå¾Ö¸¦ ÀÏÀ¸
Ų ¿£µå ½ºÅ×À̼ÇÀÌ Àüü ½Ã½ºÅÛ ¼º´ÉÀ» ÀúÇϽÃÅ°Áö ¸øÇϵµ·Ï ÇÕ´Ï´Ù.
RPS 300(Redundant Power System 300)(¿É¼Ç)ÀÇ Áö¿øÀ¸·Î 6°³ÀÇ ³×Æ®¿ö
Å· ÀåÄ¡¿¡ ¶Ù¾î³ ³»ºÎ Àü¿ø ¸®´ø´ø½Ã¸¦ Á¦°øÇÏ¿© ³»°áÇÔ¼º°ú ³×Æ®¿öÅ© °¡µ¿
½Ã°£À» Çâ»ó½ÃÄÑÁÝ´Ï´Ù.
Àå¾Ö ¹é¾÷¿¡ ´ëÇÑ
¶Ù¾î³ ¸®´ø´ø½Ã
Gigabit EtherChannel ¹× Fast EtherChannel ±â¼úÀ» ÅëÇÑ ÃÖ´ë 4 Gbps
¹× 1.6 GbpsÀÇ ´ë¿ªÆø ÁýÁßÀº ³»°áÇÔ¼ºÀ» Çâ»ó½ÃÅ°°í ½ºÀ§Ä¡ °£ ÃÊ°í¼Ó ÁýÁß
´ë¿ªÆøÀ» ¶ó¿ìÅÍ¿Í °³º° ¼¹ö¿¡ Á¦°øÇÕ´Ï´Ù.
ÀÌÁß Àå¾Ö ¹æÁö ¶ó¿ìÆà ÅäÆú·ÎÁö¸¦ »ý¼ºÇÏ´Â Cisco HSRP¸¦ Áö¿øÇÏ·Á¸é
EMI(Enhanced Multilayer Software Image )°¡ ÇÊ¿äÇÕ´Ï´Ù.
ÀÌÁß ¹éº» ¿¬°á ¹× ºñ·çÇÁ ³×Æ®¿öÅ©¸¦ À§ÇÑ IEEE 802.1D STP Áö¿øÀº ³×Æ®
¿öÅ© ±¸¼ºÀ» °£¼ÒÈÇÏ°í ³»°áÇÔ¼ºÀ» Çâ»óÇØ ÁÝ´Ï´Ù.
PVST+(Per VLAN Spanning Tree Plus)´Â ¸®´ø´ø½Ã ¼³°èÀÇ °íÀ¯ÇÑ ±â´É
ÀÎ ¿©ºÐ ¼ö¿ë´É·ÂÀ» È¿À²ÀûÀ¸·Î È°¿ëÇϱâ À§ÇØ ÀÌÁß ¸µÅ©¿¡¼ÀÇ Layer 2 °øÀ¯
¸¦ Çã¿ëÇÕ´Ï´Ù.
Àå¾Ö ¹é¾÷¿¡ ´ëÇÑ
¶Ù¾î³ ¸®´ø´ø½Ã
(°è¼Ó)
Layer 3 ·Îµå ¹ë·±½Ì ¹× ¸®´ø´ø½Ã¿¡ ´ëÇØ µ¿ÀÏÇÑ ºñ¿ëÀ» ¶ó¿ìÆÃÇÏ·Á¸é
EMI(Enhanced Multilayer Software Image)°¡ ÇÊ¿äÇÕ´Ï´Ù.
Local Proxy ARP´Â »ç¼³ VLAN ¿¡Áö¿Í ¿¬°èÇØ µ¿ÀÛÇÏ¿© ºê·Îµåij½ºÆ®¸¦
ÃÖ¼ÒÈÇÏ°í °¡¿ë ´ë¿ªÆøÀ» ±Ø´ëÈÇÕ´Ï´Ù.
VTP(VLAN Trunking Protocol) ÇÁ·ç´×(Pruning)Àº ¼ö½Å ÀåÄ¡¿¡ µµ´ÞÇÏ´Â
µ¥ ÇÊ¿äÇÑ Æ®··Å© ¸µÅ©¿¡¼¸¸ ¹æ¼Û¿ë Æ®·¡ÇÈÀÌ ¼âµµÇÏ°Ô ÇÔÀ¸·Î½á VTP Æ®··
Å©¿¡¼ÀÇ ´ë¿ªÆø ¼Òºñ¸¦ Á¦ÇÑÇÕ´Ï´Ù.
IGMP ½º´©ÇÎÀº ¸ÖƼij½ºÆ® ½ºÆ®¸²¿¡ ´ëÇÑ Å¬¶óÀ̾ðÆ®ÀÇ ½Å¼ÓÇÑ 벐¡À? ¹×
벯»Å?°¡ ÀÌ·ç¾îÁöµµ·Ï ÇÏ¸ç ´ë¿ªÆø¿¡ ¹Î°¨ÇÑ ºñµð¿À Æ®·¡ÇÈÀ» ¿äûÀÚ¿¡°Ô·Î
¸¸ Á¦ÇÑÇÕ´Ï´Ù.
MVR(Multicast VLAN Registration)Àº ¸ÖƼij½ºÆ® VALN¿¡ ¸ÖƼij½ºÆ® ½º
Æ®¸²À» ¿¬¼ÓÀûÀ¸·Î Àü¼ÛÇÏ´Â µ¿½Ã¿¡ ´ë¿ªÆø ¹× º¸¾È»óÀÇ ÀÌÀ¯·Î ½ºÆ®¸²À» °¡
ÀÔÀÚÀÇ VLANÀ¸·ÎºÎÅÍ °Ý¸®½Ãŵ´Ï´Ù.
È®À强
CWDM GBIC ¼Ö·ç¼ÇÀÌ Áö¿øµÇ¹Ç·Î ÆÄÀ̹ö¸¦ Ãß°¡·Î ¹èÄ¡ÇÏÁö ¾Ê°íµµ ´ë
¿ªÆøÀ» È®ÀåÇÒ ¼ö ÀÖ½À´Ï´Ù. ´ÜÀÏ ¸ðµå ÆÄÀ̹ö½Ö¿¡ 8±â°¡ºñÆ®ÀÇ ´ë¿ªÆøÀ» Á¦
°øÇÏ¿© µð½ºÅϽº°¡ ÃÖ´ë 100~120 km¿¡ À̸¨´Ï´Ù.
½ºÀ§Ä¡¸¶´Ù 1,005°³ÀÇ È°¼º VLANÀÌ ÀÖ´Â VALN ID¸¦ 4,096°³±îÁö Áö¿øÇÏ
´Â °ÍÀº ¹°·Ð, ½ºÀ§Ä¡º°·Î ½ºÆÐ´× Æ®¸® ÀνºÅϽº(Spanning Tree Instance)¸¦
64°³±îÁö Áö¿øÇÕ´Ï´Ù.
VLAN Æ®··Å©´Â Ç¥ÁØ ±â¹ÝÀÇ 802.1Q űëÀ̳ª ISL VLAN ¾ÆÅ°ÅØó¸¦ ÀÌ¿ë
ÇØ »ý¼ºµÉ ¼ö ÀÖ½À´Ï´Ù.
¼ºñ½º º¸¾È
³×Æ®¿öÅ© Àüü¿¡
°ÉÄ£ º¸¾È ±â´É
µ¿Àû Æ÷Æ® ±â¹ÝÀÇ º¸¾ÈÀ» À§ÇØ IEEE 802.1x°¡ Áö¿øµË´Ï´Ù.
¸ðµç VLAN»óÀÇ Cisco º¸¾È VLAN ACLÀº ±ÇÇÑÀÌ ¾ø´Â µ¥ÀÌÅÍ È帧ÀÌ
VLAN ³»¿¡¼ ¿¬°áµÇ´Â °ÍÀ» ¸·¾ÆÁÝ´Ï´Ù.
Á¦¾î Ç÷¹ÀÎ ¹× µ¥ÀÌÅÍ Ç÷¹ÀÎ Æ®·¡ÇÈÀ» À§ÇØ ¶ó¿ìÆÃµÈ ÀÎÅÍÆäÀ̽º¿¡ º¸¾È
Á¤Ã¥À» ±ÔÁ¤Çϱâ À§ÇÑ Cisco Ç¥ÁØ ¹× È®ÀåÇü IP º¸¾È RACL(Router ACL),
EMI(Enhanced Multilayer Software Image) ÇÊ¿ä.
Layer 2¿¡ ´ëÇÑ Æ÷Æ® ±â¹ÝÀÇ ACLÀº Layer 2 Æ÷Æ®º°·Î º¸¾È Á¤Ã¥ÀÌ Àû¿ëµÇ
µµ·Ï ÇØ ÁÝ´Ï´Ù.
½Ã°£À» ±âÃÊ·Î ÇÑ ACLÀº ÇÏ·ç Áß Æ¯Á¤ ±â°£ µ¿¾È º¸¾È ¼³Á¤ÀÌ ±¸ÇöµÇµµ·Ï
ÇØ ÁÝ´Ï´Ù.
»ç¼³ VLAN ¿¡Áö´Â ½ºÀ§Ä¡ Æ÷Æ®µé °£¿¡ º¸¾È°ú °Ý¸®¸¦ Á¦°øÇÔÀ¸·Î½á À½¼º
Æ®·¡ÇÈÀÌ Á÷Á¢ ÀÔ·ÂÁ¡¿¡¼ °¡»ó °æ·Î¸¦ ÅëÇØ ÁýÇÕ ÀåÄ¡·Î À̵¿ÇÏ°í ´Ù¸¥ Æ÷
Æ®·Î´Â °æ·Î°¡ ÁöÁ¤µÉ ¼ö ¾øµµ·Ï ÇÕ´Ï´Ù.
TACACS+ ¹× RADIUS(Remote Access Dial-In User Service) ÀÎÁõ Áö¿ø
Àº ½ºÀ§Ä¡ÀÇ ÅëÇÕ Á¦¾î¸¦ °¡´ÉÇÏ°Ô Çϸç, ±ÇÇÑÀÌ ¾ø´Â »ç¿ëÀÚ°¡ ±¸¼ºÀ» º¯°æ
ÇÏÁö ¸øÇϵµ·Ï ±ÔÁ¦ÇÕ´Ï´Ù.
¿¡ÀÌ¡ ±â´ÉÀ» °®Ãá MAC ÁÖ¼Ò ±â¹ÝÀÇ Æ÷Æ® ¼öÁØ º¸¾ÈÀº ±ÇÇÑÀÌ ¾ø´Â ½ºÅ×
À̼ǿ¡¼ ½ºÀ§Ä¡¿¡ ¾×¼¼½ºÇÏÁö ¸øÇϵµ·Ï ÇØ ÁÖ¸ç, Æ÷Æ® ´ç µ¿½Ã ÀåÄ¡ ¼ö¸¦ Á¦
ÇÑÇÕ´Ï´Ù .
ÄÜ¼Ö ¾×¼¼½º¿¡ ´ëÇÑ ¸ÖƼ·¹º§ º¸¾ÈÀº ±ÇÇÑÀÌ ¾ø´Â »ç¿ëÀÚ°¡ ½ºÀ§Ä¡ÀÇ ±¸¼º
À» º¯°æÇÏÁö ¸øÇϵµ·Ï ÇØ ÁÝ´Ï´Ù.
³×Æ®¿öÅ© Àü¹Ý¿¡
°ÉÄ£ º¸¾È ±â´É
(°è¼Ó)
»ç¿ëÀÚ°¡ ¼±ÅÃÇÒ ¼ö ÀÖ´Â ÁÖ¼Ò ÇнÀ ¸ðµå´Â ±¸¼ºÀ» ´Ü¼øÈÇØ ÁÖ¸ç º¸¾È ±â
´ÉÀ» Çâ»ó½ÃÄÑ ÁÝ´Ï´Ù.
DHCP Option 82 ¸±·¹ÀÌ´Â Àü¼Û DHCP°¡ DHCP Ŭ¶óÀ̾ðÆ®¿¡¼ DHCP ¼
¹ö¿¡ ¿äûÇÒ ¶§, DHCP ¸±·¹ÀÌ ¿¡ÀÌÀüÆ®(Cisco Catalyst 3550 Series
Switch)°¡ ÀÚüÀûÀÎ Á¤º¸¿Í ÷ºÎµÈ Ŭ¶óÀ̾ðÆ®ÀÇ Á¤º¸¸¦ Æ÷ÇÔÇÒ ¼ö ÀÖ°Ô ÇØ
ÁÝ´Ï´Ù.
Service
Management
¼ºñ½º °ü¸®
¿ì¼öÇÑ °ü¸®¼º
Cisco IE 2100 Series´Â ÇÁ·ÎºñÀú´×À» ÅëÇÑ Ç÷οì¿Í ÇÁ·Î±×·¡¹Ö °¡´ÉÇÑ
ÀÎÅÍÆäÀ̽º¸¦ ÅëÇÑ OSS ¾ÖÇø®ÄÉÀ̼ǰúÀÇ ÅëÇÕÀ» Áö¿øÇÕ´Ï´Ù.
SNMP(Simple Network Management Protocol) ¹öÀü 1°ú ¹öÀü 2c(¹öÀü 3
Àº ÇâÈÄ ¼ÒÇÁÆ®¿þ¾î Áö¿ø ¿¹Á¤) ¹× ÅÚ³Ý ÀÎÅÍÆäÀ̽º Áö¿øÀº Á¾ÇÕÀûÀÎ ´ë¿ª ³»
°ü¸®¸¦ Áö¿øÇÏ°í, CLI(command-line interface) ±â¹Ý °ü¸® ÄܼÖÀº ´ë¿ª ¿Ü
°ü¸®¸¦ Á¦°øÇÕ´Ï´Ù.
Cisco ¶ó¿ìÅÍ¿Í ½ºÀ§Ä¡ ¹× Çãºê¿¡ °øÅë °ü¸® ÀÎÅÍÆäÀ̽º¸¦ Á¦°øÇÏ´Â
CiscoWorks ³×Æ®¿öÅ© °ü¸® ¼ÒÇÁÆ®¿þ¾î¸¦ ÅëÇØ °³º° Æ÷Æ® ¹× °³º° ½ºÀ§Ä¡¸¶
´Ù °ü¸®ÇÒ ¼ö ÀÖ½À´Ï´Ù.
Cisco IOS CLI Áö¿øÀº ¸ðµç Cisco ¶ó¿ìÅÍ¿Í Cisco µ¥½ºÅ©Å¾ ½ºÀ§Ä¡¿¡ °ø
Åë »ç¿ëÀÚ ÀÎÅÍÆäÀ̽º¿Í ¸í·É ¼¼Æ®¸¦ Á¦°øÇÕ´Ï´Ù.
¼ºñ½º Á¦°ø¾÷ü¿¡ Á¾ÇÕÀûÀÎ MIB°¡ Á¦°øµÇ¾î ´Ù¾çÇÑ ºô¸µ ¹æ½ÄÀ» À§ÇØ
Cisco Catalyst 3550 Series¿¡ °üÇÑ Æ®·¡ÇÈ Á¤º¸¸¦ ¼öÁýÇÕ´Ï´Ù.
Cisco QPM(Quality Policy Manager) ¼Ö·ç¼ÇÀÇ Á¾´Ü°£ QoS Á¤Ã¥À» À§ÇÑ
Áö¿ø(ÇâÈÄ ¼ÒÇÁÆ®¿þ¾î Áö¿ø ¿¹Á¤)
CiscoWorks 2000 LAN °ü¸® ¼Ö·ç¼Ç Áö¿ø
SA(Service Assurance) AgentÀÇ Áö¿øÀ¸·Î LAN Àüü¿¡ °ÉÃÄ ¼ºñ½º ¼öÁØ
°ü¸®°¡ ¿ëÀÌÇÕ´Ï´Ù.
³»ÀåµÈ À¥ ±â¹Ý Cisco CMS(Cluster Management Suite) ¼ÒÇÁÆ®¿þ¾î´Â
Ç¥ÁØ À¥ ºê¶ó¿ìÀú¸¦ ÅëÇØ »ç¿ëÇϱ⠽¬¿î À¥ ±â¹Ý °ü¸® ÀÎÅÍÆäÀ̽º¸¦ Á¦°øÇÕ
´Ï´Ù.
¾×¼¼½º, ¶ó¿ìÆà ¹× VLAN ¹èÄ¡ ½Ã³ª¸®¿À¸¦ À§ÇÑ ½ºÀ§Ä¡ µ¥ÀÌÅͺ£À̽º °ü¸®
ÀÚ ÅÛÇø´Àº ³×Æ®¿öÅ© °ü¸®ÀÚ°¡ ¹èÄ¡º° ¿ä°ÇÀ» ±âÁØÀ¸·Î ¸Þ¸ð¸® ÇÒ´çÀ» ¿øÇÏ
´Â ±â´É¿¡ ½±°Ô ÃÖ´ëÈÇÒ ¼ö ÀÖ½À´Ï´Ù.
³»ÀåÇü RMON(Remote Monitoring) ¼ÒÇÁÆ®¿þ¾î ¿¡ÀÌÀüÆ®´Â Çâ»óµÈ Æ®·¡
ÇÈ °ü¸®, °¨½Ã ¹× ºÐ¼®À» À§ÇØ 4°³ÀÇ RMON ±×·ì(È÷½ºÅ丮, Åë°è, ¾Ë¸² ¹× ÀÌ
º¥Æ®)À» Áö¿øÇÕ´Ï´Ù.
´ÜÀÏ SPAN(Switch Port Analyzer) Æ÷Æ®¸¦ ÅëÇØ 9°³ÀÇ RMON ±×·ìÀ» ¸ðµÎ
Áö¿øÇÕ´Ï´Ù. µû¶ó¼ ´Ü ÇϳªÀÇ ³×Æ®¿öÅ© ºÐ¼®±â³ª RMON ÇÁ·Îºê(Probe)¿¡
¼ ÇϳªÀÇ Æ÷Æ®³ª Æ÷Æ® ±×·ì, ½ºÀ§Ä¡ Àüü¿¡ ´ëÇÑ Æ®·¡ÇÈ °¨½Ã°¡ °¡´ÉÇÕ´Ï´Ù.
DNS(Domain Name Services)´Â ºÎ¿©µÈ IP ÁÖ¼Ò¿¡ »ç¿ëÀÚ Á¤ÀÇ ÀåÄ¡ ÀÌ
¸§À» Á¦°øÇÕ´Ï´Ù.
TFTP(Trivial File Transfer Protocol)´Â Áß¾Ó ÁöÁ¡¿¡¼ÀÇ ´Ù¿î·Îµå¸¦ ÅëÇØ
¼ÒÇÁÆ®¿þ¾î ¾÷±×·¹ÀÌµå °ü¸® ºñ¿ëÀ» Àý°¨½Ãŵ´Ï´Ù.
¿ì¼öÇÑ °ü¸®¼º
(°è¼Ó)
NTP(Network Timing Protocol)´Â ÀÎÆ®¶ó³Ý ³»ÀÇ ¸ðµç ½ºÀ§Ä¡¿¡ ´ëÇØ Á¤
È®ÇÏ°í ÀÏ°üµÈ ŸÀÓ½ºÅÆÇÁ¸¦ Á¦°øÇÕ´Ï´Ù.
½Ã½ºÅÛ, ÀÌÁß Àü¿ø ÀåÄ¡, ´ë¿ªÆø »ç¿ë¿¡ ´ëÇÑ ½ºÀ§Ä¡ ·¹º§ »óÅ LED´Â
¹°·Ð, Æ÷Æ® »óÅÂ, ¹ÝÀÌÁß(half-duplex)/ÀüÀÌÁß(full-duplex)
10BaseT/100BaseTX/1000BaseT Ç¥½Ã¸¦ À§ÇÑ Æ÷Æ®º° ´Ù±â´É LED´Â
Á¾ÇÕÀûÀÌ°í Æí¸®ÇÑ ½Ã°¢Àû °ü¸® ½Ã½ºÅÛÀ» Á¦°øÇÕ´Ï´Ù.
Á¦Ç° »ç¾ç
±â´É
¼³¸í
¼º´É
24 Gbps ½ºÀ§Äª Æк긯(Cisco Catalyst 3550-12G ¹× 3550-12T),
13.6 Gbps ½ºÀ§Äª Æк긯(Cisco Catalyst 3550-48), 8.8 Gbps ½ºÀ§Äª Æк긯
(Cisco Catalyst 3550-24, 3550-24-DC ¹× 3550-24-FX)
Layer 2¿Í Layer 3¿¡¼ 12 GbpsÀÇ ÃÖ´ë Æ÷¿öµù ´ë¿ªÆø(Cisco Catalyst
3550-12G ¹× 3550-12T), Layer 2¿Í Layer 3¿¡¼ 6.8 GbpsÀÇ ÃÖ´ë Æ÷¿öµù ´ë
¿ªÆø(Cisco Catalyst 3550-48), Layer 2¿Í Layer 3¿¡¼ 4.4 GbpsÀÇ ÃÖ´ë Æ÷
¿öµù ´ë¿ªÆø(Cisco Catalyst 3550-24, 3550-24-DC ¹× 3550-24-FX)
64 ¹ÙÀÌÆ® ÆÐŶ, 17.0 Mpps Æ÷¿öµù ¼Óµµ(Cisco Catalyst 3550-12G ¹×
3550-12T), 64 ¹ÙÀÌÆ® ÆÐŶ, 10.1 Mpps Æ÷¿öµù ¼Óµµ(Cisco Catalyst 3550-
48), 64 ¹ÙÀÌÆ® ÆÐŶ, 6.6 Mpps Æ÷¿öµù ¼Óµµ(Cisco Catalyst 3550-24, 3550-
24-DC ¹× 3550-24-FX)
4 MB ¸Þ¸ð¸® ¾ÆÅ°ÅØó, ¸ðµç Æ÷Æ® °øÀ¯(Cisco Catalyst 3550-12G, 3550-
12T ¹× 3550-48), 2 MB ¸Þ¸ð¸® ¾ÆÅ°ÅØó, ¸ðµç Æ÷Æ® °øÀ¯(Cisco Catalyst
3550-24, 3550-24-DC ¹× 3550-24-FX)
CPU ¼ºê½Ã½ºÅÛÀ» À§ÇÑ 64 MB DRAM ¹× 16 MB Ç÷¡½Ã ¸Þ¸ð¸®
ÃÖ´ë 12,000°³ MAC ÁÖ¼Ò ±¸¼º °¡´É(Cisco Catalyst 3550-12G ¹× 3550-
12T), ÃÖ´ë 8,000°³ MAC ÁÖ¼Ò ±¸¼º °¡´É(Cisco Catalyst 3550-48, 3550-24,
3550-24-DC ¹× 3550-24-FX)
ÃÖ´ë 24,000°³ À¯´Ïij½ºÆ® °æ·Î ±¸¼º °¡´É(Cisco Catalyst 3550-12G and
3550-12T), ÃÖ´ë 16,000°³ À¯´Ïij½ºÆ® °æ·Î ±¸¼º °¡´É(Cisco Catalyst 3550-
48, 3550-24, 3550-24-DC ¹× 3550-24-FX)
ÃÖ´ë 8,000°³ÀÇ ¸ÖƼij½ºÆ® °æ·Î ±¸¼º °¡´É(Cisco Catalyst 3550-12G ¹×
3550-12T), ÃÖ´ë 2,000°³ÀÇ ¸ÖƼij½ºÆ® °æ·Î ±¸¼º °¡´É(Cisco Catalyst 3550-
48, 3550-24, 3550-24-DC ¹× 3550-24-FX)
MPLS ÅÂ±× ÁöÁ¤ ÇÁ·¹ÀÓ ºê¸®Â¡À» À§ÇØ ÃÖ´ë 2,000 ¹ÙÀÌÆ®±îÁö MTU
(Maximum Transmission Unit) ±¸¼º °¡´É(Cisco Catalyst 3550-12G ¹×
3550-12T), MPLS ÅÂ±× ÁöÁ¤ ÇÁ·¹ÀÓ ºê¸®Â¡À» À§ÇØ ÃÖ´ë 1,546 ¹ÙÀÌÆ®±îÁö
MTU(Maximum Transmission Unit) ±¸¼º °¡´É(Cisco Catalyst 3550-48,
3550-24, 3550-24-DC ¹× 3550-24-FX)
°ü¸®
RFC 1213
IF MIB
CISCO-CDP-MIB
CISCO-IMAGE-MIB
CISCO-FLASH-MIB
OLD-CISCO-CHASSIS-MIB
CISCO-PAGP-MIB
CISCO-VTP-MIB
CISCO-HSRP-MIB
OLD-CISCO-TS-MIB
BRIDGE-MIB (RFC 1493)
CISCO-VLAN-MEMBERSHIP-MIB
CISCO-VLAN-IFINDEX-RELATIONSHIP-MIB
CISCO-STACK-MIB
RMON 1 MIB
IGMP MIB
PIM MIB
CISCO-STP-EXTENSIONS-MIB
OSPF-MIB (RFC 1253)
IPMROUTE-MIB
CISCO-MEMORY-POOL-MIB
CISCO-RTTMON-MIB
CISCO-PROCESS-MIB
OLD-CISCO-SYS-MIB
CISCO-CONFIG-MAN-MIB
SNMP MIB II
Ç¥ÁØ
IEEE 802.1x
IEEE 802.1w
IEEE 802.1s
10BaseT, 100BaseTX ¹× 1000BaseT Æ÷Æ®¿¡¼ IEEE 802.3x
ÀüÀÌÁß(full-duplex)
IEEE 802.1D Spanning-Tree Protocol
Ç¥ÁØ (°è¼Ó)
IEEE 802.1p CoS ¿ì¼± ¼øÀ§ ÁöÁ¤
IEEE 802.1Q VLAN
IEEE 802.3 10BaseT ±Ô°Ý
IEEE 802.3u 100BaseTX ±Ô°Ý
IEEE 802.3ab 1000BaseT ±Ô°Ý
IEEE 802.3z 1000BaseX ±Ô°Ý
1000BaseX (GBIC)
1000BaseSX
1000BaseLX/LH
1000BaseZX
1000Base-CWDM GBIC 1470nm
1000Base-CWDM GBIC 1490nm
1000Base-CWDM GBIC 1510nm
1000Base-CWDM GBIC 1530nm
1000Base-CWDM GBIC 1550nm
1000Base-CWDM GBIC 1570nm
1000Base-CWDM GBIC 1590nm
1000Base-CWDM GBIC 1610nm
RMON I ¹× II Ç¥ÁØ
SNMPv1 ¹× SNMPv2c (SNMPv3-ÇâÈÄ ¼ÒÇÁÆ®¿þ¾î Áö¿ø ¿¹Á¤)
Y2K
Y2K ȣȯ
Ä¿³ØÅÍ ¹× ÄÉÀÌºí¸µ
10BaseT Æ÷Æ®: RJ-45 Ä¿³ØÅÍ; Category 3, 4 2Á¶ ¶Ç´Â
ºñÀý¿¬ Æ®À§½ºÆ¼µå Æä¾î(UTP) ÄÉÀÌºí¸µ 5°³
100BaseTX Æ÷Æ®: RJ-45 Ä¿³ØÅÍ; Category 5 UTP ÄÉÀÌºí¸µ 2Á¶
100BaseFX Æ÷Æ®: MT-RJ Ä¿³ØÅÍ, 50/125 ¶Ç´Â 62.5/125 ¹ÌÅ©·Ð MMF
(Micron Multimode Fiber-Optic) ÄÉÀÌºí¸µ
ÄÉÀ̺í À¯Çü Cisco ºÎÇ° ¹øÈ£
Cisco ºÎÇ° ¹øÈ£
- 1¹ÌÅÍ, MT-RJ-to-SC ¸ÖƼ¸ðµå ÄÉÀ̺í
CAB-MTRJ-SC-MM-1M
- 3¹ÌÅÍ, MT-RJ-to-SC ¸ÖƼ¸ðµå ÄÉÀ̺í
CAB-MTRJ-SC-MM-3M
- 5¹ÌÅÍ, MT-RJ-to-SC ¸ÖƼ¸ðµå ÄÉÀ̺í
CAB-MTRJ-SC-MM-5M
- 1¹ÌÅÍ, MT-RJ-to-ST ¸ÖƼ¸ðµå ÄÉÀ̺í
CAB-MTRJ-ST-MM-1M
- 3¹ÌÅÍ, MT-RJ-to-ST ¸ÖƼ¸ðµå ÄÉÀ̺í
CAB-MTRJ-ST-MM-3M
- 5¹ÌÅÍ, MT-RJ-to-ST ¸ÖƼ¸ðµå ÄÉÀ̺í
CAB-MTRJ-ST-MM-5M
Ä¿³ØÅÍ ¹× ÄÉÀÌºí¸µ (°è¼Ó)
1000BaseT Æ÷Æ®: RJ-45; Category 5 UTP ÄÉÀÌºí¸µ 2Á¶
1000BaseT GBIC ±â¹Ý Æ÷Æ®: RJ-45 Ä¿³ØÅÍ; Category 5 UTP ÄÉÀÌºí¸µ
2Á¶
1000BaseSX, -LX/LH, -ZX ¹× CWDM GBIC ±â¹Ý Æ÷Æ®: SC ÆÄÀ̹ö Ä¿³Ø
ÅÍ, SMF(Single-mode) ¶Ç´Â MMF(Multimode fiber)
Cisco GigaStack GBIC Æ÷Æ®: ±¸¸®¼±À» ÀÌ¿ëÇÏ´Â Cisco GigaStack ÄÉÀÌ
ºí¸µ
°ü¸® ÄÜ¼Ö Æ÷Æ®: 8ÇÉ RJ-45 Ä¿³ØÅÍ, PC¿¡ ¿¬°áÇÒ ¼ö ÀÖ´Â RJ-45-to-DB9
¾î´ðÅÍ°¡ ´Þ¸° RJ-45-to-RJ-45 ·Ñ¿À¹ö ÄÉÀ̺í. ´Ü¸»±â¿¡ ¿¬°áÇÏ·Á¸é RJ-45-
to-DB25 ¿À¸ñÇü(female) DTE(Data-Terminal-Equipment) ¾î´ðÅÍ »ç¿ë
(Cisco¿¡¼ º°µµ ÁÖ¹® °¡´É, ºÎÇ° ¹øÈ£ ACS-DSBUASYN=)
Àü¿ø Ä¿³ØÅÍ
³»ºÎ Àü¿ø ÀåÄ¡¸¦ »ç¿ëÇϰųª Cisco RPS(Redundant Power System) 300À»
»ç¿ëÇÏ¿© ½ºÀ§Ä¡¿¡ Àü·ÂÀ» °ø±ÞÇÒ ¼ö ÀÖ½À´Ï´Ù. Ä¿³ØÅÍ´Â ½ºÀ§Ä¡ µÞ¸é¿¡ ÀÖ
½À´Ï´Ù.
³»ºÎ Àü¿ø ÀåÄ¡ Ä¿³ØÅÍ
³»ºÎ Àü¿ø ÀåÄ¡´Â ÀÚµ¿ ¹üÀ§ Á¶Á¤ ÀåÄ¡ÀÔ´Ï´Ù.
³»ºÎ Àü¿ø ÀåÄ¡´Â 100 ~ 240 VAC »çÀÌÀÇ °ø±Þ Àü¾ÐÀ» Áö¿øÇÕ´Ï´Ù.
Á¦°øµÈ AC Àü¿ø Äڵ带 »ç¿ëÇÏ¿© AC Àü¿ø Ä¿³ØÅ͸¦ AC Àü¿ø Äܼ¾Æ®¿¡
¿¬°áÇÕ´Ï´Ù.
Cisco RPS Ä¿³ØÅÍ
ÀÌ Ä¿³ØÅÍ´Â AC ÀÔ·ÂÀ» »ç¿ëÇÏ°í ½ºÀ§Ä¡¿¡ DC Ãâ·ÂÀ» °ø±ÞÇÏ´Â Cisco
RPS 300(¿É¼Ç)¿¡ ¿¬°áÇÒ ¼ö ÀÖ½À´Ï´Ù.
ÀÌ Ä¿³ØÅÍ´Â 6°³ÀÇ ¿ÜºÎ ³×Æ®¿öÅ© ÀåÄ¡¸¦ Áö¿øÇÒ ¼ö ÀÖ°í ÇÑ ¹ø¿¡ ÇÑ ´ëÀÇ
Àå¾Ö°¡ ¹ß»ýµÈ ÀåÄ¡¿¡ Àü·ÂÀ» °ø±ÞÇÏ´Â 300¿ÍÆ® ÀÌÁß Àü¿ø ½Ã½ºÅÛÀÔ´Ï´Ù.
ÀÌ Ä¿³ØÅÍ´Â ¿¬°áµÈ ÀåÄ¡ÀÇ ³»ºÎ Àü¿ø ÀåÄ¡¿¡ Àå¾Ö°¡ ¹ß»ýÇϸé À̸¦ ÀÚµ¿
À¸·Î °¨ÁöÇÏ¿© °íÀå³ ÀåÄ¡¿¡ Àü·ÂÀ» °ø±ÞÇÔÀ¸·Î½á ³×Æ®¿öÅ© Æ®·¡ÇÈÀÇ ¼Õ½Ç
À» ¹æÁöÇÕ´Ï´Ù.
³»ºÎ Àü¿ø ÀåÄ¡°¡ ÀÛµ¿À» ¸ØÃ߰ųª ±³Ã¼µÇ¾úÀ» °æ¿ì, Cisco RPS 300Àº ÀÚ
µ¿À¸·Î ÀåÄ¡¿¡ ´ëÇÑ Àü¿ø °ø±ÞÀ» Áß´ÜÇÕ´Ï´Ù.
ÀÌÁß Àü¿ø °ø±Þ ÀåÄ¡ ¼ÒÄÏ¿¡´Â Cisco RPS 300(¸ðµ¨ PWR300-AC-RPS-
N1)¸¸À» ¿¬°áÇØ¾ß ÇÕ´Ï´Ù.
Ç¥½Ã±â
Æ÷Æ® »óź° LED: Æ÷Æ® »óź° LED: ¸µÅ© ¹«°á¼º, »ç¿ë ºÒ´É, È°¼º, ¼Óµµ
¹× ÀüÀÌÁß(full-duplex) Ç¥½Ã
½Ã½ºÅÛ »óÅ LED: ½Ã½ºÅÛ »óÅ LED: ½Ã½ºÅÛ, RPS ¹× ´ë¿ªÆø »ç¿ë Ç¥½Ã
Ä¡¼ö ¹× Áß·®(H x W x D)
6.7 x 40.4 x 44.5 cm(2.63 x 15.9 x 17.5 in.)
(Cisco Catalyst 3550-12G ¹× 3550-12T)
4.45 x 36.6 x 44.5 cm(1.75 x 14.4 x 17.5 in.)
(Cisco Catalyst 3550-24 ¹× 3550-24-DC)
Ä¡¼ö ¹× Áß·®(HxWxD) (°è¼Ó) Ä¡¼ö ¹× Áß·®(H x W x D) (°è¼Ó)
4.45 x 41.3 x 44.5 cm(1.75 x 16.3 x 17.5 in.)
(Cisco Catalyst 3550-48 ¹× 3550-24-FX)
1.5 RU(rack-unit) ³ôÀÌ(Cisco Catalyst 3550-12G ¹× 3550-12T)
1.0 RU(Rack-Unit) ³ôÀÌ(Cisco Catalyst 3550-48, 3550-24,
3550-24-DC ¹× 3550-24-FX)
7.26 kg(16 lb)(Cisco Catalyst 3550-12G ¹× 3550-12T)
5.0 kg(11 lb)(Cisco Catalyst 3550-24 ¹× 3550-24-DC)
5.9 kg(13 lb)(Cisco Catalyst 3550-48)
5.45 kg(12 lb)(Cisco Catalyst 3550-24-FX)
ȯ°æ ¹üÀ§
ÀÛµ¿ ¿Âµµ: 0 ~ 45¡Æ C(32 ~ 113¡Æ F)
º¸°ü ¿Âµµ: -25 ~ 70¡Æ C(-13 ~ 158¡Æ F)
ÀÛµ¿ »ó´ë ½Àµµ: 10 ~ 85% (ºñÀÀ°á)
ÀÛµ¿ °íµµ: ÃÖ´ë 3,049 m(10,000 ft}
º¸°ü °íµµ: ÃÖ´ë 4,573 m(15,000 ft)
Àü¿ø ¿ä°Ç
Àü·Â ¼Òºñ: 190W(ÃÖ´ë), ½Ã°£ ´ç 650 BTU(Cisco Catalyst 3550-12G ¹×
3550-12T); 65W(ÃÖ´ë), ½Ã°£ ´ç 222 BTU(Cisco Catalyst 3550-24); 86W
(ÃÖ´ë), ½Ã°£ ´ç 294 BTU(Cisco Catalyst 3550-48); 72W(ÃÖ´ë), ½Ã°£
´ç 250 BTU(Cisco Catalyst 3550-24-DC); 125W(ÃÖ´ë), ½Ã
°£ ´ç 425 BTU(Cisco Catalyst 3550-24-FX)
AC °ø±Þ Àü¾Ð/ÁÖÆļö: 100 ~ 127/200 ~ 240 VAC
(ÀÚµ¿ Á¶Á¤), 50 ~ 60 Hz
DC °ø±Þ Àü¾Ð: -36 ~ -72VDC@2A(Cisco
Catalyst 3550-24-DC)
MTBF(Mean time between failure)
110,332 ½Ã°£(Cisco Catalyst 3550-12G)
113,658 ½Ã°£(Cisco Catalyst 3550-12T)
193,000 ½Ã°£(Cisco Catalyst 3550-24)
163,000 ½Ã°£(Cisco Catalyst 3550-48)
183, 000 ½Ã°£(Cisco Catalyst 3550-24-DC)
186,000 ½Ã°£(Cisco Catalyst 3550-24-FX)
±ÔÁ¦ ±â°ü ½ÂÀÎ
¾ÈÀü ÀÎÁõ
UL to UL 1950, Third Edition
c-UL to CAN/CSA 22.2 No.
950-95, Third Edition
TUV/GS to EN 60950(¼öÁ¤
Á¶Ç× A1-A4 ¹× A11)
CB to IEC 60950(±¹°¡º°
·Î ÆíÂ÷ ÀÖÀ½)
NOM to NOM-019-SCFI
CE Marking
ÀüÀÚÆÄ ¹æÃâ ÀÎÁõ
FCC Part 15 Class A
EN 55022 Class A
(CISPR 22 Class A)
VCCI Class A
AS/NZS 3548 Class A
BSMI
CE Marking
NEBS(Network Equipment Building Systems) (3550-24-DC) NEBS
(Network Equipment Building Systems) (3550-24-DC)
Bellcore
GR-1089-CORE
GR-63-CORE
SR-3580 Level 3
º¸Áõ
Á¦ÇÑÀû Æò»ý º¸Áõ
¼ºñ½º ¹× Áö¿ø
¾Æ·¡ Ç¥¿¡ ¼³¸íµÈ ¼ºñ½º ¹× Áö¿ø ÇÁ·Î±×·¥Àº Cisco Desktop Switching Service and Support ¼Ö·ç¼ÇÀÇ
ÀϺηΠÁ¦°øµÇ¸ç, Cisco·ÎºÎÅÍ Á÷Á¢, ȤÀº ÆǸŠ´ë¸®Á¡À» ÅëÇØ ±¸ÇÒ ¼ö ÀÖ½À´Ï´Ù.
¼ºñ½º ¹× Áö¿ø
±â´É
ÀÌÁ¡
°í±Þ ¼ºñ½º
Cisco Total Implementation Solutions (TIS)-Cisco¿¡
¼ Á÷Á¢ ±¸ÀÔ °¡´ÉPackaged Total
Implementation Solutions (Packaged TIS)-¸®¼¿
·¯¸¦ ÅëÇØ ±¸ÀÔ °¡´É
ÇÁ·ÎÁ§Æ® °ü¸®
»çÀÌÆ® ¼³¹® Á¶
»ç, ±¸¼º ¹èÄ¡
¼³Ä¡, ÅؽºÆ® ¹×
ÄÆ¿À¹ö
±³À°
ÁÖ¿ä À̵¿, Ãß°¡,
º¯°æ(MAC)
¼³°è °ËÅä ¹× Á¦Ç° ½ºÅ×ÀÌ¡
±âÁ¸ Á÷¿ø º¸¿Ï
±â´É¼º°ú ¿ä±¸ÀÇ ÀÏÄ¡
À§Çè °æ°¨
±â¼ú Áö¿ø ¼ºñ½º
SMARTnet¢â ¹× SMARTnet Onsite(OS)-Cisco¿¡
¼ Á÷Á¢ ÀÌ¿ëPackaged SMARTnet-ÆÇ
¸Å ´ë¸®Á¡À» ÅëÇØ ÀÌ¿ë °¡´É
1³â 365ÀÏ ¼ÒÇÁÆ®¿þ
¾î ¾÷µ¥ÀÌÆ® Áö¿ø
±â¼ú ÀÚ·á¿¡ À¥ ¾×
¼¼½º °¡´É
±â¼ú Áö¿ø ¼¾Å͸¦
ÅëÇÑ ÀüÈ Áö¿ø
Çϵå¿þ¾î ºÎÇ° Á¶
±â ±³Ã¼
»çÀü Á¶Ä¡ ¹× ¿¹»ó ¹®Á¦ ÇØ°á °¡´É
CiscoÀÇ Àü¹®Áö½Ä°ú Á¤º¸ÀÇ È°¿ë
À» ÅëÇÑ ¼ÒÀ¯ ºñ¿ë Àý°¨
³×Æ®¿öÅ© ´Ù¿îŸÀÓ ÃÖ¼ÒÈ
ÁÖ¹® Á¤º¸
¸ðµ¨ ¹øÈ£
±¸¼º
WS-C3550-12G
10°³ 1000BaseX Æ÷Æ® + 2°³ 10/100/1000BaseT Æ÷Æ®
1.5 RU(Rack Unit) ½ºÅÃÇü, ¸ÖƼ·¹ÀÌ¾î ±â°¡ºñÆ® ÀÌ´õ³Ý ½ºÀ§Ä¡
¿ÏÀüÇÑ µ¿Àû IP ¶ó¿ìÆà Á¦°ø
WS-C3550-12T
10°³ 10/100/1000BaseT Æ÷Æ® + 2°³ 1000BaseX Æ÷Æ®
1.5 RU(rack unit) ½ºÅÃÇü, ¸ÖƼ·¹ÀÌ¾î ±â°¡ºñÆ® ÀÌ´õ³Ý ½ºÀ§Ä¡
¿ÏÀüÇÑ µ¿Àû IP ¶ó¿ìÆà Á¦°ø
WS-C3550-24-SMI
24°³ 10/100 Æ÷Æ® + 2°³ 1000BaseX Æ÷Æ®
1°³ RU ½ºÅÃÇü, ¸ÖƼ·¹ÀÌ¾î ½ºÀ§Ä¡
SMI(Standard Multilayer Software Image)°¡ ¼³Ä¡µÇ¾î ÀÖÀ¸¸ç, ¿ÏÀüÇÑ µ¿Àû
IP ¶ó¿ìÆÃÀ¸·Î ¾÷±×·¹ÀÌµå °¡´É
WS-C3550-24-DC-SMI
24 10/100 Æ÷Æ® + 2 1000BaseX ports 24°³ 10/100 Æ÷Æ® + 2°³ 1000BaseX Æ÷Æ®
1°³ RU ½ºÅÃÇü, DC Àü¿ø ¸ÖƼ·¹ÀÌ¾î ½ºÀ§Ä¡
SMI(Standard Multilayer Software Image)°¡ ¼³Ä¡µÇ¾î ÀÖÀ¸¸ç, ¿ÏÀüÇÑ µ¿Àû
IP ¶ó¿ìÆÃÀ¸·Î ¾÷±×·¹ÀÌµå °¡´É
WS-C3550-24-FX-SMI
24°³ 100FX Æ÷Æ® + 2°³ 1000BaseX Æ÷Æ®
1°³ RU ½ºÅÃÇü, ¸ÖƼ·¹ÀÌ¾î ½ºÀ§Ä¡
SMI(Standard Multilayer Software Image)°¡ ¼³Ä¡µÇ¾î ÀÖÀ¸¸ç, ¿ÏÀüÇÑ µ¿Àû
IP ¶ó¿ìÆÃÀ¸·Î ¾÷±×·¹ÀÌµå °¡´É
WS-C3550-24-EMI
24°³ 10/100 Æ÷Æ® + 2°³ 1000BaseX Æ÷Æ®
1°³ RU ½ºÅÃÇü, ¸ÖƼ·¹ÀÌ¾î ½ºÀ§Ä¡
EMI(Enhanced Multilayer Software Image) ¼³Ä¡
¿ÏÀüÇÑ µ¿Àû IP ¶ó¿ìÆà Á¦°ø
WS-C3550-48-SMI
48°³ 10/100 Æ÷Æ® + 2°³ 1000BaseX Æ÷Æ®
1°³ RU ½ºÅÃÇü, ¸ÖƼ·¹ÀÌ¾î ½ºÀ§Ä¡
SMI(Standard Multilayer Software Image)°¡ ¼³Ä¡µÇ¾î ÀÖÀ¸¸ç, ¿ÏÀüÇÑ µ¿Àû IP µ¿Àû ¶ó¿ìÆÃÀ¸·Î ¾÷±×·¹ÀÌµå °¡´É
WS-C3550-48-EMI
48°³ 10/100 Æ÷Æ® + 2°³ 1000BaseX Æ÷Æ®
1°³ RU ½ºÅÃÇü, ¸ÖƼ·¹ÀÌ¾î ½ºÀ§Ä¡
EMI(Enhanced Multilayer Software Image) ¼³Ä¡
¿ÏÀüÇÑ µ¿Àû IP Á¦°ø
CD-3550-EMI=
Cisco Catalyst 3550-24 ¹× 3550-48 ½ºÀ§Ä¡ Ç¥ÁØ ¹öÀüÀ» À§ÇÑ EMI(Enhanced
Multilayer Software Image) ¾÷±×·¹À̵å Å°Æ®
¿ÏÀüÇÑ µ¿Àû IP ¶ó¿ìÆà Á¦°ø
RCKMNT-3550-1.5RU=
Cisco Catalyst 3550-12G ¹× 3550-12T ½ºÀ§Ä¡¸¦ À§ÇÑ ¿¹ºñ ·¢ ÀåÂø Å°Æ®
RCKMNT-1RU=
Cisco Catalyst 3550-24 ¹× 3550-48 ½ºÀ§Ä¡¸¦ À§ÇÑ ¿¹ºñ ·¢ ÀåÂø Å°Æ®
Cisco Á¦Ç°¿¡ °üÇÑ ÀÚ¼¼ÇÑ ³»¿ëÀº ¾Æ·¡ ¿¬¶ôó·Î ¹®ÀÇÇϽʽÿÀ.
¹Ì±¹ ¹× ij³ª´Ù: 800 553-NETS (6387)
À¯·´: 32 2 778 4242
¿À½ºÆ®·¹Àϸ®¾Æ: 612 9935 4107
±âŸ ±¹°¡: 408 526-7209
À¥ URL:
http://www.cisco.com
<¾÷µ¥ÀÌÆ®µÈ: 2002³â 6¿ù 21ÀÏ>
Åùè, ȹ°, Äü¼ºñ½º µî ´Ù¾çÇÑ ¿î¼Û¹æ¹ýÀ» ÀÌ¿ëÇÏ¿© ¹è¼ÛÀÌ °¡´ÉÇÕ´Ï´Ù.
¿îÀÓºñ´Â ±¸¸ÅÀÚ ºÎ´ãÀÔ´Ï´Ù.
°¢ Á¦Á¶»çÀÇ A/S ±ÔÁ¤¿¡ µû¸¨´Ï´Ù.
¼ÒºñÀÚ º¸È£¹ý¿¡ µû¸¨´Ï´Ù.
¹®ÀÇ : 02-7989-114
À̸§ :
³»¿ë :
ÆòÁ¡
¡Ú
¡Ú¡Ú
¡Ú¡Ú¡Ú
¡Ú¡Ú¡Ú¡Ú
¡Ú¡Ú¡Ú¡Ú¡Ú
°í°´Æò°¡ :
ÆòÁ¡
¡Ú¡Ú¡Ú¡Ú¡Ú
»óÇ°¿¡ ´ëÇØ ±Ã±ÝÇÑ Á¡À» ÇØ°áÇØ µå¸³´Ï´Ù.
¹øÈ£
Á¦¸ñ
ÀÛ¼ºÀÚ
ÀÛ¼ºÀÏ
Á¶È¸
[»èÁ¦]
[Ãë¼Ò]
»óÇ°Èı⸦ ÀÛ¼ºÇØ ÁÖ¼¼¿ä.
Copyright ¨Ï
·£Àåºñ
All Rights Reserved.
TEL : 02-798-9114 , FAX : 02-716-7229
»óÈ£¸í : (ÁÖ)·£Àåºñ »ç¾÷ÀÚµî·Ï¹øÈ£ : 106-86-16143 106-86-16143 Åë½ÅÆǸž÷½Å°í¹øÈ£ : Á¦ 2006-¼¿ï¿ë»ê-00850È£ ´ëÇ¥ : ¾È±âÁß
[
ÀÌ¿ë¾à°ü
]
°³ÀÎÁ¤º¸Ãë±Þ¹æħ
°³ÀÎÁ¤º¸´ã´çÀÚ :
¹Ú¿ë±¸ºÎÀå
»ç¾÷Àå¼ÒÀçÁö : ¼¿ï ¿ë»ê±¸ ûÆÄ·Î 83, 4µ¿9¿ 2,3È£(¿øÈ¿·Î3°¡,¿øÈ¿ÀüÀÚ»ó°¡)