³ôÀº À¯¿¬¼ºÀ» Áö´Ñ ½ºÅà °¡´É ¿£ÅÍÇÁ¶óÀÌÁî±Þ L3 ½ºÀ§Äª
NETGEARÀÇ È¿À²ÀûÀÎ ºñ¿ëÀ» ÀÚ¶ûÇÏ´Â ±â°¡ºñÆ® ÀÌ´õ³Ý ½ºÀ§Ä¡´Â ÃÖ´ëÀÇ µ¥ÀÌÅÍ Àü¼Û·ü°ú À¯¿¬¼ºÀ» Á¦°øÇÏ¿© ³×Æ®¿öÅ© ÇÏ´ÜÀÇ °í¼Ó, °í¹ÐµµÀÇ ¿öÅ©±×·ì ½ºÀ§Ä¡ ȤÀº ¼ºÀåÇÏ´Â ³×Æ®¿öÅ© ¹× ³ôÀº ´ë¿ªÆøÀ» ¿ä±¸ÇÏ´Â ÆÄÀÏ ¹× ¾îÇø®ÄÉÀÌ¼Ç ¼¹ö¸¦ À§ÇÑ ¹éº»À¸·Î ¾È¼º¸ÂÃãÀÎ Á¦Ç°ÀÔ´Ï´Ù.
ProSafe GSM7328S GSM7352S °ü¸®Çü ½ºÀ§Ä¡´Â °¢°¢ 24°³ ¹× 48°³ÀÇ °í¹Ðµµ Copper Á¢¼ÓÀ» À§ÇÑ ÀÚµ¿ÀÎ½Ä 10/100/1000Mbps ÀÎÅÍÆäÀ̽º Æ÷Æ®¸¦ ³»ÀåÇÏ°í ÀÖÀ¸¸ç 4°³ÀÇ Hot Swappable small form-factor pluggable (SFP) ±â°¡ºñÆ® ÀÎÅÍÆäÀ̽º¸¦ Áö³à ±¤¹üÀ§ ±â°¡ºñÆ® ÀÌ´õ³Ý Á¢¼ÓÀ» À§ÇÑ ¿É¼ÇÀÇ ±¤Á¢¼ÓÀ» Áö¿øÇÕ´Ï´Ù. ÀÌ ¸ðµç ½ºÀ§Ä¡µéÀº 2°³ÀÇ 10 ±â°¡ºñÆ® ÀÌ´õ³Ý small form-factor pluggable(SFP+) ÀÎÅÍÆäÀ̽º¿Í 10 ±â°¡ºñÆ® ÀÌ´õ³Ý ȤÀº 48 ±â°¡ºñÆ® ½ºÅÂÅ· Á¢¼ÓÀ» À§ÇÑ È®Àå ¸ðµâ ½½·ÔÀ» Á¦°øÇÕ´Ï´Ù. ÀÌ ½ºÀ§Ä¡µéÀÇ non-blocking µðÀÚÀÎÀº ¸ðµç Æ÷Æ®¿¡¼ ÃÖ´ëÀÇ À¯¼±¼Óµµ Áö¿ø ¹× ³·Àº latency throughputÀ» Áö¿øÇÕ´Ï´Ù.
Layer 3 ½ºÀ§Ä¡ÀÇ ¸ðµç °ü¸® ±â´ÉµéÀº ¾î¶°ÇÑ Ãß°¡ ºñ¿ë ¾øÀÌ ¾ðÁ¦ ¾îµð¼³ª VLAN ¹× ³×Æ®¿öÅ© ¼¼±×¸ÕÆ® »çÀÌ¿¡¼ ¾ÈÁ¤ÀûÀÎ ¶ó¿ìÆà ±â´ÉÀ» º¸ÀåÇÏ°í ÀÖ½À´Ï´Ù. ÀÌ ½ºÀ§Ä¡µéÀº 48Gbps ¾ç¹æÇâ ¸µÀ» ÅëÇØ ÃÖ´ë 8´ë±îÁö ½ºÅÂÅ·À» ÅëÇØ ÇϳªÀÇ IP·Î ÅëÁ¦°¡ °¡´ÉÇÑ °í¹Ðµµ ½ºÀ§Ä¡·Î Àçź»ýÇÒ ¼ö ÀÖ½À´Ï´Ù.
öÀúÇÑ º¸¾È ±â´ÉÀ¸·Î´Â IEEE802.1x Æ÷Æ® ±â¹Ý ÀÎÁõ ¹× Access Control List·Î ¿ÀÁ÷ Çã°¡ ¹ÞÀº »ç¿ëÀÚ¸¸ ³×Æ®¿öÅ© Á¢¼ÓÀÌ °¡´ÉÇϵµ·Ï µµ¿ÍÁÖ¸ç ½ºÀ§Ä¡µéÀÇ º¸¾È °ü¸® ±â´ÉÀº Web GUI¸¦ À§ÇÑ Secure Sockets Layer(SSLv3) ¹× command line sessionÀ» À§ÇÑ Secured Shell(SSH) ȤÀº ³×Æ®¿öÅ© ¸Å´ÏÁö¸ÕÆ® ¼ÒÇÁÆ®¿þ¾î¸¦ À§ÇÑ SNMPv3¸¦ ÅëÇØ Áö¿øµË´Ï´Ù. Layer3 ½ºÀ§Äª, ±â°¡ºñÆ® Á¢¼Ó, ³ôÀº °¡Ä¡¿Í È¿À²ÀûÀÎ ºñ¿ë, ½ºÅÂÅ·ÀÇ À¯¿¬¼º, Àú·ÅÇÑ À¯Áö °ü¸® ºñ¿ë µî ºñ¿ë¿¡ ¹Î°¨ÇÑ Á¶Á÷¿¡¼ ¿öÅ©±×·ìÀ¸·ÎÀÇ ¹èÄ¡¿¡ ÀÌ»óÀûÀÎ Á¦Ç°ÀÎ NETGEAR ProSafe Gigabit Layer 3 Stackable ½ºÀ§Ä¡»ÓÀÔ´Ï´Ù.
ÅõÀÚ ´ëºñ ³ôÀº È¿À²¼ºÀ» Áö´Ñ NETGEAR ½ºÀ§Ä¡´Â ÇϳªÀÇ ³×Æ®¿öÅ© ÀÎÇÁ¶ó¸¦ ÅëÇØ º¸´Ù ¾ÈÁ¤ÀûÀÌ°í ½Å·Ú¼º ÀÖ´Â À½¼º, µ¿¿µ»ó, µ¥ÀÌÅÍ ¼ºñ½º Àü¼ÛÀ» À§ÇÑ ÃÖ¼±ÀÇ ¼±ÅÃÀÔ´Ï´Ù.
°·ÂÇÑ ³×Æ®¿öÅ·
µ¥½ºÅ©Åé ½ºÀ§Äª ȯ°æ¿¡¼ ¸ðµç 10/100/1000 ÀÎÅÍÆäÀ̽º¸¦ À§ÇÑ Ç® QoS ÄÁÆ®·Ñ ±â´ÉÀ» Áö´Ñ À¯¼± ÆÛÆ÷¸Õ½º´Â ¸Å¿ì Áß¿äÇÕ´Ï´Ù. 2°³ÀÇ ºôÆ®ÀÎ 10GE SFP+ ½½·Ô ¹× 2°³ÀÇ 10GE ȤÀº 48 ±â°¡ºñÆ® ½ºÅÂÅ· ¿¬°áÀ» À§ÇÑ ¸ðµâ º£ÀÌ´Â ½ºÀ§Ä¡µé°£ÀÇ ½ºÅÂÅ·À» ÇϵçÁö ¼¹ö¿¡ Á¢¼ÓÇϵçÁö ȤÀº µ¥ÀÌÅ͸¦ Áß¾ÓÀ¸·Î ÅëÇÕÇϵçÁö »ó°ü¾øÀÌ ÃÖ°íÀÇ ÆÛÆ÷¸Õ½º¸¦ º¸ÀåÇÕ´Ï´Ù.
Æí¸®ÇÑ »ç¿ë
´Ù·ç±â ÆíÇÑ GUI ±â¹Ý ÀåºñÀÇ ¼³Á¤, »ê¾÷ Ç¥ÁØÀÇ command line interface(CLI)¸¦ ÅëÇØ IT ´ã´çÀÚµéÀÇ ¼ö°í¿Í ³×Æ®¿öÅ© °ü¸® ¹× ÅëÁ¦ ½Ã°£À» Çö°ÝÈ÷ ÁÙ¿©ÁÝ´Ï´Ù. EZ-Config ÅøÀº Ãʱ⠼³Á¤ ´Ü°è¸¦ °£°áÇÏ°í Æí¸®ÇÏ°Ô µµ¿ÍÁÖ¸ç Æ÷Æ® »ç¿ë¿¡ °üÇÑ ¼Õ¼ö¿î ÃßÀû ¹× Æ÷Æ®µéÀÌ ¾î¶»°Ô »ç¿ëµÇ¾ú´ÂÁö¸¦ ¾Ë·ÁÁÖ´Â ÅؽºÆ® ±â¹Ý ¼³¸í µîÀ» »ç¿ëÇÒ ¼ö ÀÖ½À´Ï´Ù.
À¯¿¬ÇÑ ½ºÅÂÅ·
½ºÅÂÅ· ´É·ÂÀº ÀÎÅÚ¸®ÀüÆ® ¾ç¹æÇâ ½ºÅÂÅ· ¸µÅ©¸¦ »ç¿ëÇÏ¸é¼ ÃÖ´ë 8°³ÀÇ ½ºÀ§Ä¡µéÀ» ÇϳªÀÇ ½Ì±Û IP Àåºñ·Î ÅëÇÕÇϵµ·Ï µµ¿ÍÁÝ´Ï´Ù. ÀÌ·¸°Ô À¯¿¬ÇÑ ½ºÅÂÅ·Àº ´õ ±ä Àå°Å¸®ÀÇ 10GE ±¤Á¢¼Ó ¾÷¸µÅ© ȤÀº 48 ±â°¡ºñÆ® ½ºÅÂÅ· Á¢¼ÓÀ» À§ÇÑ AX742 Å°Æ®¸¦ ÅëÇØ °¡´ÉÇÕ´Ï´Ù.
Non-Stop ¼ºñ½º
ÀÌ »õ·Î¿î 2°³ÀÇ ½ºÀ§Ä¡µéÀº ½ºÀ§Ä¡ÀÇ ¸ÞÀÎ ÆÄ¿ö ½áÇöóÀ̷μ ºÐ¸®°¡ °¡´ÉÇÑ Àü¿ø ¸ðµâÀ» »ç¿ëÇÏ°í ÀÖ½À´Ï´Ù. Àü¿ø °ø±Þ¿¡ ¹®Á¦°¡ ¹ß»ý ½Ã ÀÌ ½ºÀ§Ä¡µéÀº Àü¿ø °ø±ÞÀ» À§Çؼ ¿ÜºÎ RPS Àåºñ¸¦ »ç¿ëÇÏ°Ô µÇ¸ç Àüü ½ºÀ§Ä¡ÀÇ ±³Ã¼ ÇÊ¿ä ¾øÀÌ ³»ºÎ Àü¿ø ¸ðµâ¸¸ ±³Ã¼ ÇÏ´Â °ÍÀ¸·Î ¹®Á¦ ÇØ°áÀÌ °¡´ÉÇÕ´Ï´Ù. À̷νá Àü¿ø ¹®Á¦·Î ÀÎÇÑ ½Ã°£ ¼Òºñ ¹× ºñ¿ë ¹ß»ýÀ» Çö°ÝÈ÷ ÁÙÀÏ ¼ö°¡ ÀÖ½À´Ï´Ù.
Technical Specifications
Physical Interfaces
- 24 or 48 RJ45 10/100/1000 ports with
Auto-Uplink¢â
- 4 shared SFP ports for fiber Gigabit
interfaces
- 2 built-in 10 Gigabit SFP+ ports
- 2 optional 10 Gigabit module bays
- RS-232 console
- USB port
Layer 2 Services
- IEEE 802.1Q Static VLAN (Up to 4k VLAN ID)
- IEEE 802.1p Class of Service (CoS)
- IEEE 802.1D Spanning Tree Protocol
- IEEE 802.1v Protocol VLAN & Port VLAN
- Voice VLAN
- Guest VLAN
- IP subnet VLAN
- MAC-based VLAN
- IEEE 802.1 Q-in-Q
- IEEE 802.1w Rapid Spanning Tree
- IEEE 802.1s Multiple Spanning Tree
- IEEE 802.3ad Link Aggregation (Static or LACP) up to 48 trunks
- IEEE 802.1x Port Access Authentication
- IGMP v1, v2, v3 snooping support
- IGMP querier
- Network storm protection including broadcast, multicast and unicast traffic
- Static multicast filtering
- Port locking
- Ingress rate limit in 1 Kbps increments
- GARP/GVRP/GMRP
- DHCP snooping
- IP source guard
- Dynamic ARP inspection
- TACACS+
- LLDP
- LLDP-MED
- ISDP
- sFlow
- DoS
- Private group
- Protected port
- DHCP L2 relay
- MLD v1, v2 snooping
Layer 3 Services
- VLAN routing
- Port routing
- RIP v1/v2 (RFC 1058, 2453)
- OSPF v2/v3 (RFC 1583, 2328)
- OSPF equal-cost multi-path (4 - ECMP routes)
- VRRP (RFC 2338, 2787) 64 instances
- Access control lists (ACL) - MAC, IP, TCP
- ACLs - 1,024 Global
- ACL over VLAN
- Dynamic ACL
- COS
- DiffServ QoS (RFC 2998)
- DNS Caching
- DHCP/BOOTP relay -primary and backup (RFC 3046, option 82)
- ICMP throttling
- DHCP v4/v6 server
- Captive portal
- Auto VoIP
- IP Helper
- PIM-DM (RFC 3973)
- PIM-SM (RFC 4601)
- IGMP v2,v3
- IGMP proxy
- DVMRP (RFC 1075)
- IPv6 unicast routing
- Neighbor discovery
- IPv6 tunnel
- OSFPv3 (RFC 2740)
- IPv6 PIM-SM
- IPv6 PIM-DM
- MLD (RFC 2710)
- MLD proxy
- DNSv6 (RFC 4472)
Switch Management Specifications
- SNMP v1, v2c, v3 with multiple IP addresses
- RFC 1157, 1901-1910, 2574, 2575
- RFC 768 UDP
- UDP Relay
- RFC 854-859 telnet
- RFC 951 BOOTP
- RFC 1213 MIB II
- RFC 1757 RMON groups 1,2,3, and 9
- RFC 1215 SNMP traps
- RFC 1493 Bridge MIB
- RFC 1643 Ethernet Interface MIB
- RFC 1534 DHCP and BOOTP interoperation
- RFC 2131, 2132 DHCP and BOOTP
- RFC 2865 RADIUS (both switch and management access)
- RFC 2866 RADIUS accounting
- RFC 3580 VLAN assignment via RADIUS (Dynamic VLAN)
- Private enterprise MIB
- Port mirroring support
- Flow-based mirroring
- RFC 2030 Simple Network Time Protocol (SNTP)
- RFC 1027 Proxy ARP
- SYSLOG
- TFTP, SFTP, HTTP, SCP, or local USB flash firmware upgrade
- RFC 1519 CIDR
- Proxy ARP
- DNS lookup
- Port description
- Auto install
- IPv6 management
- Dual image
Single IP Address Management
(firmware version 7.3 or higher)
- Manage up to 48 fully managed switches
- Feature can be used with the following models:
- FSM726E, FSM7226RS, FSM7250RS
- FSM7328S, FSM7352S, FSM7328PS, FSM7352PS
- GSM7224R, GSM7248R
- GSM7328S, GSM7352S
Performance Specifications
- Forwarding modes: Store-and-forward
- GSM7328S: 144 Gbps; 107.1 Mpps
- GSM7352S: 192 Gbps; 285.7 Mpps
- Switch latency: < 6 us for 64-byte frames (10 G to 10 G) < 2 us for 64-byte frames (1 G to 1 G)
- System memory: 256 MB
- Packet buffer memory: 786 KB
- Code storage (flash): 32 MB
- Address database size: 8 K media access control (MAC) addresses
- Number of VLANs: 4 k
- Number of multicast groups: 1024
- Number of trunks: 64
- Number of queues: 8
- Number of routes: 480
- Jumbo frame support: up to 9 K packet size
- Acoustic noise:
GSM7328S 44 dB
GSM7352S 44 dB
- Heat dissipation:
GSM7328S 260.49 BTU/hr
GSM7352S 389.20 BTU/hr
- Mean time between failures (MTBF):
GSM7328S: 211,069.9 hours (~24.1 years) at 25¨¬ C
GSM7352S: 169,522.96 hours (~19.4 years) at 25¨¬ C
GSM7328Sv2: 98,705.41hours (~11.3 years) at 55¨¬ C
GSM7352Sv2: 83,550.17 hours (~9.5 years) at 55¨¬ C
User Interfaces
- Command Line Interface (CLI) via console port
- Web-based management via embedded HTTP server protected with Secured Sockets Layer
- (SSLv3) or Transport Layer Security (TLS v1)
- Telnet remote login (5 sessions) securable with Secured Shell (SSH v1.5, v2)
LEDs
- Per port: Speed, link, activity
- Per device: Power, fan status, stack ID, RPS, master
Network Standards Compatibility
- IEEE 802.3i 10BASE-T
- IEEE 802.3u 100BASE-TX
- IEEE 802.3u 100BASE-FX*
- IEEE 802.3ab 1000BASE-T
- IEEE 802.3z 1000BASE-X
- IEEE 802.3x Flow Control
- IEEE 802.3ae 10000BASE-X
*Tested with Fiberxon SFP Modules
Physical Specifications
- Dimensions (w x d x h): 440 x 391 x 43 mm (17.3 x 15.4 x 1.7 in)
- Weight:
GSM7328Sv2: 6.3 kg (13.89 lb)
GSM7352Sv2: 6.8 kg (14.99 lb)
Environmental Specifications
- Operating temperature:
GSM7328S/GSM7352S: 0¡É to 50¡É (32 to 122¢µ) Thermal sensor with SNMP Trap settings
- Storage temperature: -20¡É to 70¡É (-4 to 158¢µ)
- Operating humidity: 90% maximum relative humidity, non-condensing
- Storage humidity: 95% maximum relative humidity, non-condensing
- Operating altitude: 3,000 m (10,000 ft) maximum
- Storage altitude: 3,000 m (10,000 ft) maximum
Electrical Specifications
- Power Consumption:
-GSM7328S 65.64W maximum
-GSM7352S 91.8W maximum
Electromagnetic Emissions
- CE mark
- EN 55022 Class A - Emissions
- EN 55024 - Immunity
- FCC Part 15 Class A
- VCCI Class A
- C-Tick
Electromagnetic Safety
- CE mark
- EN 60950-1
- UL/cUL 60950-1
- CB
- CCC
Warranty
- NETGEAR Lifetime Warranty¢Ó
GBICs
- AGM731F (SFP 1000BASE-SX LC)
- AGM732F (SFP 1000BASE-LX LC)
- AXM761 (SFP+ 10GBASE-SR LC)
- AXM762 (SFP+ 10GBASE-LR LC)
- AXM751 (XFP 10GBASE-SR LC)
- AXM752 (XFP 10GBASE-LR LC)
Modules
- AX742 (24 Gigabit Stacking Kit, comes with 2 modules and one stacking cable)
- AX741 (10 Gigabit XFP adapter module)
- AX743 (10 Gigabit SFP+ adapter module)
- AX744 (10 Gigabit CX4 module, 1 port CX4)
- APS135W (Extractible power module)
Package Contents
- ProSafe Gigabit L3 Managed Switch
(GSM7328Sv2 or GSM7352Sv2)
- Null modem cable
- Rubber footpads
- Power cable
- Rack-mount kit
- Installation guide
- Resource CD-ROM
- Warranty/support information card
Ordering Information
- North America
GSM7328S-200NAS
GSM7352S-200NAS
- Europe, Korea
GSM7328S-200EUS
GSM7352S-200EUS
- Asia
GSM7328S-200AJS
GSM7352S-200AJS
ProSupport Service Packs Available
GSM7328S
OnCall 24x7, Category 3
- PMB0333
XPressHW, Category 3
- PRR0333-100
GSM7352S
OnCall 24x7, Category 4
- PMB0334
XPressHW, Category 4
- PRR0334-100
|