º¸¾È Á¢¼Ó ·Î±×ÀÎ | ȸ¿ø°¡ÀÔ | Àå¹Ù±¸´Ï | °í°´¼¾ÅÍ
TEL : 02-798-9114
HPE-ARUBA[ÆÄ°Ý°¡]
CISCO [ƯÆǸðµ¨]
D-Link [Àü±¹ÃÖÀú°¡]
NETGEAR [ÃÖÀú°¡°ø±Þ]
Alcatel-Lucent Enterprise
½Ã½ºÄÚ Cisco
Cisco SB/Pro
ZyXEL
APC[ÀüÈ­¹®ÀÇ]
¼ÖÅØ(Soltech)
TP-LINK
¿¡ÀÌÅÙ[ATEN]
µðÆ÷±×(Defog)
DASAN(´Ù»ê)
UTM/VPN/¹æÈ­º®
ETK
¹«¼±·£/Wireless
¹«¼±°øÀ¯±â/¹«¼±AP/¾ÈÅ׳ª
À¯¼±Àåºñ/Network
½ºÀ§Ä¡/·£Ä«µå/ÇÁ¸°Åͼ­¹ö
POE ½ºÀ§Ä¡
10±â°¡ºñÆ® ÀÌ´õ³Ý
·£°ø±¸,CCTV ÀâÀÚÀç
FIBER Àåºñ/Á¡ÆÛÄÚµå
RACK/UPS/KVM
°¢Á¾ÄÉÀ̺í/Á¨´õ
¿µ»ó/À½Çâ/ºÐ¹è±â/°øÀ¯
½Ã¸®¾ó Åë½ÅÁ¦Ç°
¸ÖƼÆ÷Æ®/ÄÁ¹öÅÍ
»ê¾÷¿ë Á¦Ç°±º
CCTV ºñµð¿À¼­¹ö
USB/1394/ÁÖº¯±â±â
======================
AP
HIKVISION
INTEL
MOXA
Chesio (10G NIC)
IPTIME
Uniclass KVM
TYCO(AMP)
3COM
Britz
======================
°¡°ÝÁ¶Á¤
======================
802.11N
UBIQUITI
·£Àåºñ ¼Ò½Ä/¹®ÀÇ
°ø±Þ/±¸Ãà»ç·Ê
(ÁÖ)·£Àåºñ ÀÚ·á½Ç
 
ºñ¹Ð¹øÈ£ È®ÀÎ ´Ý±â
POE ½ºÀ§Ä¡
POE ½ºÀ§Ä¡ > POE 12Æ÷Æ® > 10/100 > Netgear FS728TLP 24Æ÷Æ® 10/100, 4Æ÷Æ® 10/100/1000 2Combo SFP SLOT, 12Æ÷Æ® POE, 100Watt
     
 ÀÌÀü»óÇ° Netgear FS728TLP 24Æ÷Æ® 10/100, 4Æ÷Æ® 10/100/1000 2Combo SFP SLOT, 12Æ÷Æ® POE, 100Watt ´ÙÀ½»óÇ°
 
 
     
ÆǸŰ¡°Ý : 297,000¿ø
¼ö·® EA
 
 
 
 
 
 
 
 
 
»óÇ° »ó¼¼ ¼³¸í
 
 
 

NETGEARÀÇ ÆнºÆ® ÀÌ´õ³Ý ½º¸¶Æ® ½ºÀ§Ä¡µéÀº °­·ÂÇÑ L2 ±â´É ¹× º¸´Ù ¾÷±×·¹À̵åµÈ ÆÛÆ÷¸Õ½º ¹× ³ôÀº È°¿ë¼ºÀ» Á¦°øÇÕ´Ï´Ù. ÀÌ ½ºÀ§Ä¡µéÀº ³×Æ®¿öÅ© È¿À²¼º, ¿î¿µ ºñ¿ë Àý¾à ¹× ¼Õ½¬¿î °ü¸® µîÀ» ÇÊ¿ä·Î ÇÏ¸ç ¾ÈÁ¤¼º°ú ÆÛÆ÷¸Õ½º¸¦ Áß¿ä½Ã ÇÏ´Â Áß¼Ò±Ô¸ð »çÀÌÁî ³×Æ®¿öÅ©¸¦ À§ÇØ Æ¯º°È÷ µðÀÚÀÎµÈ Á¦Ç°ÀÔ´Ï´Ù.


ÀÌ ½Ã¸®Áî´Â ³× °¡Áö Á¦Ç°À¸·Î ±¸¼ºµÇ¾ú½À´Ï´Ù. Áï 26 ¹× 50 Æ÷Æ® ÆнºÆ® ÀÌ´õ³Ý ½º¸¶Æ® ½ºÀ§Ä¡¿Í 12°³ÀÇ PoE Æ÷Æ®¸¦ Áö´Ñ 28Æ÷Æ® ÆнºÆ® ÀÌ´õ³Ý ½º¸¶Æ® ½ºÀ§Ä¡ ¹× 24°³ÀÇ PoE/PoE+ Æ÷Æ®¸¦ Áö´Ñ 28Æ÷Æ® ÇÏÀÌ ÆÄ¿ö ½º¸¶Æ® ½ºÀ§Ä¡ ÀÌ·¸°Ô ³× °¡Áö ¸ðµ¨ÀÔ´Ï´Ù.  ÀÌ ¸ðµç ½ºÀ§Ä¡µéÀº  ±â°¡ºñÆ® ȤÀº ±¤Á¢¼ÓÀ» À§ÇØ Àü¿ë ±â°¡ºñÆ® SFP Æ÷Æ®¸¦ ³»ÀåÇÏ°í ÀÖ½À´Ï´Ù.

ÀÌ NETGEARÀÇ  ÆнºÆ® ÀÌ´õ³Ý ½º¸¶Æ® ½ºÀ§Ä¡µéÀº  ÇÕ¸®ÀûÀÎ ºñ¿ë°ú ³ôÀº °¡Ä¡¸¦ ¼±È£ÇÏ´Â SMB ȯ°æ¿¡ ÃÖÀûÀÇ Á¦Ç°ÀÔ´Ï´Ù.

 

ÇÏÀ̶óÀÌÆ®

ÇöÀç ³×Æ®¿öÅ©ÀÇ È¿À²¼ºÀ» À¯ÁöÇÏ¸ç ²÷±è¾ø´Â °í¼ÓÀÇ Áß¾Ó ³×Æ®¿öÅ©·Î ÅëÇÕ Áö¿ø
- ÆнºÆ® ÀÌ´õ³ÝÀº  ´ë´Ù¼öÀÇ ¼Ò±Ô¸ð ³×Æ®¿öÅ© Æ®·¡ÇÈ¿¡¼­ ÇÊ¿äÇÑ ÃÖ°íÀÇ °¡Ä¡¸¦ ÃæÁ·
- ¸ðµç ¸ðµ¨µéÀº ±â°¡ºñÆ® ¹éº»À̳ª ¼­¹ö¿ÍÀÇ ¼Õ½¬¿î ¿¬°áÀ» À§Çؼ­ Gigabit Copper ¹× Fiber ¾÷¸µÅ© Æ÷Æ®¸¦ žÀç
- Çʼö L2 ³×Æ®¿öÅ© ±â´ÉµéÀº ³×Æ®¿öÅ© ¼Óµµ¿Í »ó°ü¾øÀÌ Àüü ³×Æ®¿öÅ© »ó¿¡¼­ ¼³Á¤ ¹× Á¤Ã¥ÀÇ ÀÏ°ü¼ºÀ» º¸ÀåÇÔ.
- È¿À²ÀûÀÎ ³×Æ®¿öÅ© ´ë¿ªÆø °ü¸® ¹× °í±Þ ¸ÖƼij½ºÆà ÇÊÅ͸µÀ» Á¦°øÇÏ´Â IGMP ¹× MLD snooping



NETGEAR¸¦ ÅëÇØ Ä£È¯°æÀûÀÎ ³×Æ®¿öÅ© ±¸Ãà
- PoE ¸ðµ¨ÀÌ ¾Æ´Ñ °æ¿ì ÆÒ¸®½º µðÀÚÀÎÀ¸·Î Á¶¿ëÇÑ ÀÛµ¿À¸·Î ÄèÀûÇÑ ¾÷¹« ȯ°æ Á¶¼º
- PoE ¸ðµ¨¿¡¼­ Áß¿äÇÑ °í¼ÓÀÇ ÆÒÀ» ÅëÇØ ¼ÒÀ½ ¼öÁØÀ» ÃÖ¼ÒÈ­Çϱâ À§ÇØ ÀÏÁ¤ ¿Âµµ À̻󿡼­¸¸ ÀÛµ¿Çϵµ·Ï ÆÒ ÅëÁ¦ °¡´É
- º¸´Ù ³ªÀº Á¦¾î ¹× ÃÖÀûÈ­µÈ Àåºñ »ç¿ëÀ» À§Çؼ­ PoE·Î Àü·ÂÀ» °ø±Þ ¹ÞÀº ÀåºñµéÀÇ Àü¿ø ¿Â/¿ÀÇÁ ŸÀÓ ½ºÄÉÁÙ¸µÀÌ °¡´ÉÇÑ PoE ŸÀÌ¸Ó ±â´É
- Energy Efficient Ethernet(IEEE802.3az)¸¦ ÅëÇØ ¿¡³ÊÁö Àý¾à ¹× OPEX °¨¼Ò



º¸´Ù ¼Õ½¬¿î ³×Æ®¿öÅ© ¼³Ä¡
- ¼Õ½¬¿î VoIP ¼³Ä¡¸¦ À§ÇÑ Auto Voice VLAN
- IP °¨½Ã ½Ã½ºÅÛÀÇ ¼Õ½¬¿î ¼³Ä¡¸¦ À§ÇÑ Auto Video
- ³×Æ®¿öÅ© Á¢¼Ó ÄÁÆ®·ÑÀÇ ¼³Á¤À» À§ÇÑ °£ÆíÇÑ °¡À̵åÀÎ ACL ¸¶¹ý»ç
- ´Ù¼öÀÇ ½ºÀ§Ä¡ Ž»ö, ¹èÄ¡, ¸ð´ÏÅ͸µ ¹× Æß¿þ¾î ¾÷±×·¹À̵带 À§ÇÑ °­·ÂÇÑ µµ±¸ÀÎ,  ½º¸¶Æ® ÄÁÆ®·Ñ ¼¾ÅÍ
- NMS300, NETGEAR Network Management SystemÀ» ÅëÇØ ¸ðµç NETGEAR ºñÁî´Ï½º Àåºñ¿Í µ¿½Ã¿¡ ¹èÄ¡ ¹× ÅëÇÕ °ü¸®°¡ °¡´É



'ºò IT'°¡ ¾Æ´Ñ '½º¸¶Æ® IT'
- ´Ù¼öÀÇ ½ºÀ§Ä¡ ¹èÄ¡¸¦ À§ÇÑ À¥ ±â¹Ý °ü¸® GUI ȤÀº ½º¸¶Æ® ÄÁÆ®·Ñ ¼¾Å͸¦ ÅëÇÑ Æí¸®ÇÑ °ü¸®
- ±âÁ¸ ³×Æ®¿öÅ©¿¡¼­ ¾î¶°ÇÑ Ç¥ÁØ ±â¹Ý ÀåºñÇÏ°íµµ »óÈ£ ȣȯÀÌ °¡´ÉÇÑ Ç¥ÁØ ±â¹Ý ±â¼ú Áö¿ø
- ³×Æ®¿öÅ©ÀÇ ¾ÈÁ¤¼º ¹× ½Å·Ú¼ºÀ» Çâ»ó½ÃÅ°´Â µà¾ó Æß¿þ¾î À̹ÌÁö
- NETGEARÀÇ Æò»ý Çϵå¿þ¾î Ç°Áú º¸Áõ Á¦µµ·Î ÇâÈÄ ¼­ºñ½º¿¡ ´ëÇÑ °ÆÁ¤ ÇؼÒ
- Æí¸®ÇÑ A/S Á¤Ã¥ ¹× ³×Æ®¿öÅ© ±â¼ú »ó´ã

ÅëÇÕµÈ ³×Æ®¿öÅ© ¾îÇø®ÄÉÀ̼Ç


NETGEARÀÇ ÆнºÆ® ÀÌ´õ³Ý ½º¸¶Æ® ½ºÀ§Ä¡µéÀº SMBÀÇ ³×Æ®¿öÅ©¸¦  À§ÇÑ ÃÖ¼±ÀÇ ¼±ÅÃÀ̸ç ÅõÀÚ ´ëºñ ³ôÀº °¡Ä¡¸¦ Á¦°øÇÕ´Ï´Ù.

  • ºñ¿ë È¿À²ÀûÀÎ ÆнºÆ® ÀÌ´õ³Ý
  • ³×Æ®¿öÅ© ¹éº» ¹× ¼­¹ö¿ÍÀÇ Á¢¼Ó¿¡ ÇÊ¿äÇÑ ¾ÈÁ¤ÀûÀÎ ´ë¿ªÆø Áö¿øÀ» À§ÇÑ ±â°¡ºñÆ® ¾÷¸µÅ©
  • Æ®·¡ÇÈ °ü¸® ±â´ÉÀ» ÅëÇØ ³×Æ®¿öÅ© ÇϴܱîÁö ÀÎÅÚ¸®ÀüÆ®ÇÑ ¼º´ÉÀ» Áö¿øÇÏ´Â ºñ¿ë È¿À²ÀûÀÎ ½º¸¶Æ® ½ºÀ§Ä¡
  • Voice, video ¹× WLANÀ» ÇϳªÀÇ ¶È°°Àº ÅëÇÕ Ç÷§Æû¿¡¼­ ¼Õ½±°í °£ÆíÇÏ°Ô ¹èÄ¡°¡ °¡´ÉÇÑ ³ôÀº È°¿ë¼º º¸Àå
  • Æò»ý Ç°Áú º¸Áõ ¹× öÀúÇÑ »çÈÄ Áö¿ø ¼­ºñ½º

1

FS526T_FS728TLP_FS728TP_FS750T2 Diagram 

.

 

±â¼ú »ç¾ç


Model

FS526Tv2

FS728TLP

FS728TP

FS750T2

10/100Mbps ports

24

24

24

48

Gigabit ports

2

2

4

2

SFP ports

¡¡

2

2

¡¡

# of PoE ports

¡¡

12

24

¡¡

Total PoE Power budget (Watts)

¡¡

100

192

¡¡

Max MAC entries

8K

8K

4K

8K

Buffer size

4Mb

4Mb

1Mb

2Mb

EEE

¡î

¡î

¡î

¡¡

FAN

0

1

1

0

Acoustic Noise
Level @25C (dBA)

0

30.7

38.1

0

MTBF

334,168 hrs

755,725 hrs

237,497 hrs

59,800 hrs

L2 Services - VLANs

VLAN (# Supported)

 128

128

128

64

IEEE 802.1Q VLAN Tagging

Yes

IP based VLANs

Yes

no

MAC based VLANs

Yes

no

Port- based VLAN

No

Yes

Voice VLAN

Based on phones OUI bytes (internal database, or user-maintained) or protocols (SIP, H323 and SCCP)

no

NetworkSecurity

IEEE 802.1x Radius PortAccess

 Authentication

Yes

No

Guest VLAN

Yes

No

RADIUS Accounting

Yes

No

MAC lockdown by the number of MACs

Yes

No

Dynamic learned entries per port

600

600

128

¡¡

Static entiries per port

20

20

20

¡¡

Network Storm Protection, DoS

Yes¡¡

No

Broadcast,Unicast,

 MulticastDoSProtection

Yes

No

DoS attacks

Yes

No

IP-based ACLs

Yes

 No

MAC (Trusted MAC)

Yes

 No

L4 ACL

Yes

 No

Protected Port

Yes

 No

Model

FS526Tv2

FS728TLP

FS728TP

FS750T2

L2 Services -Availability

IEEE 802.3ad - LAGs

Yes

No

    LACP

Yes ( (8 LAGS with max. of 8 members in each LAG))

6 LAGs with max of 8 memebers in each LAG

Broadcast Storm Control

Yes

No

IEEE 802.3x (Full Duplex and flow control)

Yes

IEEE 802.1D Spanning Tree Protocol

Yes

IEEE 802.1w Rapid Spanning Tree

Yes

IEEE 802.1s Multiple Spanning Tree

No

No

Yes

 No

BPDU Guard

Yes

 No

DoS Prevention

Yes

No

PoETimer

¡¡

Yes

Yes

¡¡

L2 Services - MulticastFiltering

IGMP Snooping (v1, v2 and v3)

Yes

 No

Max. Multicast Group

128

128

512

¡¡

IGMP Snooping queries

Yes 

 No

Block unknown Multicast

Yes

 No

L3 Services -DHCP

DNS Client

No

No

Yes

No

DHCP Filtering

Yes

 No

Network Monitoring and DiscoveryServices

802.1ab LLDP and LLDP-MED

Yes

 No

SNMP

V1, V2,V3

v1 and v2

RMON 1,2,3,9

Yes

 No

ifTable

Yes

Quality of Service (QoS)

Number of Priority Queues

8

8

8

4

TCP/UDP-baesd QoS

 No

 No

Yes 

 No

Rate limiting

Yes 

Yes 

Egress only

 No

DiffServ QoS 

 No

 No

Yes 

 No

IEEE 802.1p COS 

Yes 

DstMAC and IP 

Yes 

 No

IPv4 DSCP 

Yes 

 No

IPv4 TOS

Yes 

Yes

No

 No

Model

FS526Tv2

FS728TLP

FS728TP

FS750T2

Strick, or WRED (Weighted Deficit Round Robin) 

Both

WRR

Auto-VoIP

Yes, based on protocols (SIP, H323 and SCCP) or on OUI bytes (default database and user-based OUIs) in the phone source MACaddress

 No

Auto Video

Yes 

 No

Port Mirroring (ingress and egress)

Yes

IEEE NetworkProtocols

IEEE 802.3 Ethernet

IEEE 802.3z Gigabit Ethernet1000BASE-SX/LX

IEEE 802.1D Spanning Tree (STP)

IEEE 802.3i 10BASE-T

IEEE 802.3adTrunking(LACP)

IEEE 802.1s Multiple Spanning Tree (MSTP)

IEEE 802.3u 100BASE-T

IEEE 802.1AB LLDP with ANSI/TIA-1057 (LLDP-MED)

IEEE 802.1w Rapid Spanning Tree (RSTP)

IEEE 802.3ab 1000BASE-T

IEEE 802.1p Class ofService

IEEE 802.1X Radius network accesscontrol

IEEE 802.1Q VLAN Tagging

IEEE 802.3af(PoE)

 

IEEE 802.3x full-duplex flowcontrol

 

 

Management

Password management

Yes

Configurable Management VLAN

Yes

no

Admin access control via Radius and TACACS+

 No

 No

Yes 

 No

Web-based graphical user interface (GUI)

Yes

Smart Control Center (SCC) for multi-switch management

Yes

Dual Software (firmware) image

Yes

 No

Dual Configuration file

Yes

 No

Cable Test utility

Yes

 No

File transfers (uploads, downloads)

TFTP /HTTP

No

HTTP Download (firmware)

Yes

No

LEDs

Per port

Speed, Link,Activity

Per device

Power, Fan andPoEPower Status (PoEmodel only)

PhysicalSpecifications

Weight (kg)

1.35

2.92

3.57

3.2

Dimensions (WxDxH) mm

326x168x43

440x204x43

440x257x43

440x205x43

Power Consumption (when all ports used, line-rate traffic and maxPoEif applicable)

Worst case, all ports used, line-rate traffic, max PoE 

12w

124w

256w

19.65w

Model

FS526Tv2

FS728TLP

FS728TP

FS750T2

EnvironmentalSpecifications

Operating: 

Operating Temperature 

32¡Æ to 122¡ÆF (0¡Æ to 50¡ÆC) 

Humidity 

90% maximum relative humidity, non-condensing 

Altitude

10,000 ft (3,000 m)maximum

Storage:

Storage Temperature 

– 4¡Æ to 158¡ÆF (–20¡Æ to 70¡ÆC) 

Humidity 

95% maximum relative humidity, non-condensing 

Altitude

10,000 ft (3,000 m)maximum

Electromagnetic Emissions andImmunity

Certifications

CE mark, commercial 

FCC Part 15 Class A, VCCI Class A 

Class A EN 55022 (CISPR 22) Class A 

Class A C-Tick 

EN 50082-1 

EN55024

CCC

Safety

Certifications

CE mark, commercial 

CSA certified (CSA 22.2 #950) 

UL listed (UL 1950)/cUL IEC 950/EN60950

Warranty andSupport

ProSafe Lifetime Warranty¢Ó

Included,lifetime

ProSupportLifetime 24x7 Advanced

TechnicalSupport*

Included, OneYear

PackageContent

All models

ProSafe¢ç Fast Ethernet Smart Switch

¡¡

Power cord 

¡¡

Rack-mounting kit 

¡¡

Resource CD with links to online documentation, installation guides, Web-management user manual, Smart Control Center (SCC) software and user guide.

Optional Modules andAccessories

    AFM735

100Base-FX SFP GBIC (Multimode)

    AGM731F

1000Base-SX SFP GBIC (Multimode)

    AGM732F

1000Base-LX SFP GBIC (Single mode)

 
Åùè, È­¹°, Äü¼­ºñ½º µî ´Ù¾çÇÑ ¿î¼Û¹æ¹ýÀ» ÀÌ¿ëÇÏ¿© ¹è¼ÛÀÌ °¡´ÉÇÕ´Ï´Ù.

¿îÀÓºñ´Â ±¸¸ÅÀÚ ºÎ´ãÀÔ´Ï´Ù.
°¢ Á¦Á¶»çÀÇ A/S ±ÔÁ¤¿¡ µû¸¨´Ï´Ù.
¼ÒºñÀÚ º¸È£¹ý¿¡ µû¸¨´Ï´Ù.

¹®ÀÇ : 02-7989-114
 
 
 
 
 
À̸§ :
³»¿ë :
ÆòÁ¡
°í°´Æò°¡ : ÆòÁ¡ ¡Ú¡Ú¡Ú¡Ú¡Ú  
 
 
 
 
»óÇ°¿¡ ´ëÇØ ±Ã±ÝÇÑ Á¡À» ÇØ°áÇØ µå¸³´Ï´Ù.
¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ Á¶È¸
 
 
»óÇ°Èı⸦ ÀÛ¼ºÇØ ÁÖ¼¼¿ä.
 

Copyright ¨Ï ·£Àåºñ All Rights Reserved. TEL : 02-798-9114 , FAX : 02-716-7229
»óÈ£¸í : (ÁÖ)·£Àåºñ   »ç¾÷ÀÚµî·Ï¹øÈ£ : 106-86-16143 [»ç¾÷ÀÚÁ¤º¸È®ÀÎ]   Åë½ÅÆǸž÷½Å°í¹øÈ£ : Á¦ 2006-¼­¿ï¿ë»ê-00850È£   ´ëÇ¥ : ¾È±âÁß
[ÀÌ¿ë¾à°ü°³ÀÎÁ¤º¸Ãë±Þ¹æħ °³ÀÎÁ¤º¸´ã´çÀÚ : ¹Ú¿ë±¸ºÎÀå   »ç¾÷Àå¼ÒÀçÁö : ¼­¿ï ¿ë»ê±¸ ûÆÄ·Î 83, 4µ¿9¿­ 2,3È£(¿øÈ¿·Î3°¡,¿øÈ¿ÀüÀÚ»ó°¡)