|
NETGEARÀÇ ÆнºÆ® ÀÌ´õ³Ý ½º¸¶Æ® ½ºÀ§Ä¡µéÀº °·ÂÇÑ L2 ±â´É ¹× º¸´Ù ¾÷±×·¹À̵åµÈ ÆÛÆ÷¸Õ½º ¹× ³ôÀº È°¿ë¼ºÀ» Á¦°øÇÕ´Ï´Ù. ÀÌ ½ºÀ§Ä¡µéÀº ³×Æ®¿öÅ© È¿À²¼º, ¿î¿µ ºñ¿ë Àý¾à ¹× ¼Õ½¬¿î °ü¸® µîÀ» ÇÊ¿ä·Î ÇÏ¸ç ¾ÈÁ¤¼º°ú ÆÛÆ÷¸Õ½º¸¦ Áß¿ä½Ã ÇÏ´Â Áß¼Ò±Ô¸ð »çÀÌÁî ³×Æ®¿öÅ©¸¦ À§ÇØ Æ¯º°È÷ µðÀÚÀÎµÈ Á¦Ç°ÀÔ´Ï´Ù.
ÀÌ ½Ã¸®Áî´Â ³× °¡Áö Á¦Ç°À¸·Î ±¸¼ºµÇ¾ú½À´Ï´Ù. Áï 26 ¹× 50 Æ÷Æ® ÆнºÆ® ÀÌ´õ³Ý ½º¸¶Æ® ½ºÀ§Ä¡¿Í 12°³ÀÇ PoE Æ÷Æ®¸¦ Áö´Ñ 28Æ÷Æ® ÆнºÆ® ÀÌ´õ³Ý ½º¸¶Æ® ½ºÀ§Ä¡ ¹× 24°³ÀÇ PoE/PoE+ Æ÷Æ®¸¦ Áö´Ñ 28Æ÷Æ® ÇÏÀÌ ÆÄ¿ö ½º¸¶Æ® ½ºÀ§Ä¡ ÀÌ·¸°Ô ³× °¡Áö ¸ðµ¨ÀÔ´Ï´Ù. ÀÌ ¸ðµç ½ºÀ§Ä¡µéÀº ±â°¡ºñÆ® ȤÀº ±¤Á¢¼ÓÀ» À§ÇØ Àü¿ë ±â°¡ºñÆ® SFP Æ÷Æ®¸¦ ³»ÀåÇÏ°í ÀÖ½À´Ï´Ù.
ÀÌ NETGEARÀÇ ÆнºÆ® ÀÌ´õ³Ý ½º¸¶Æ® ½ºÀ§Ä¡µéÀº ÇÕ¸®ÀûÀÎ ºñ¿ë°ú ³ôÀº °¡Ä¡¸¦ ¼±È£ÇÏ´Â SMB ȯ°æ¿¡ ÃÖÀûÀÇ Á¦Ç°ÀÔ´Ï´Ù.
ÇÏÀ̶óÀÌÆ®
ÇöÀç ³×Æ®¿öÅ©ÀÇ È¿À²¼ºÀ» À¯ÁöÇÏ¸ç ²÷±è¾ø´Â °í¼ÓÀÇ Áß¾Ó ³×Æ®¿öÅ©·Î ÅëÇÕ Áö¿ø - ÆнºÆ® ÀÌ´õ³ÝÀº ´ë´Ù¼öÀÇ ¼Ò±Ô¸ð ³×Æ®¿öÅ© Æ®·¡ÇÈ¿¡¼ ÇÊ¿äÇÑ ÃÖ°íÀÇ °¡Ä¡¸¦ ÃæÁ· - ¸ðµç ¸ðµ¨µéÀº ±â°¡ºñÆ® ¹éº»À̳ª ¼¹ö¿ÍÀÇ ¼Õ½¬¿î ¿¬°áÀ» À§Çؼ Gigabit Copper ¹× Fiber ¾÷¸µÅ© Æ÷Æ®¸¦ žÀç - Çʼö L2 ³×Æ®¿öÅ© ±â´ÉµéÀº ³×Æ®¿öÅ© ¼Óµµ¿Í »ó°ü¾øÀÌ Àüü ³×Æ®¿öÅ© »ó¿¡¼ ¼³Á¤ ¹× Á¤Ã¥ÀÇ ÀÏ°ü¼ºÀ» º¸ÀåÇÔ. - È¿À²ÀûÀÎ ³×Æ®¿öÅ© ´ë¿ªÆø °ü¸® ¹× °í±Þ ¸ÖƼij½ºÆà ÇÊÅ͸µÀ» Á¦°øÇÏ´Â IGMP ¹× MLD snooping
NETGEAR¸¦ ÅëÇØ Ä£È¯°æÀûÀÎ ³×Æ®¿öÅ© ±¸Ãà - PoE ¸ðµ¨ÀÌ ¾Æ´Ñ °æ¿ì ÆÒ¸®½º µðÀÚÀÎÀ¸·Î Á¶¿ëÇÑ ÀÛµ¿À¸·Î ÄèÀûÇÑ ¾÷¹« ȯ°æ Á¶¼º - PoE ¸ðµ¨¿¡¼ Áß¿äÇÑ °í¼ÓÀÇ ÆÒÀ» ÅëÇØ ¼ÒÀ½ ¼öÁØÀ» ÃÖ¼ÒÈÇϱâ À§ÇØ ÀÏÁ¤ ¿Âµµ À̻󿡼¸¸ ÀÛµ¿Çϵµ·Ï ÆÒ ÅëÁ¦ °¡´É - º¸´Ù ³ªÀº Á¦¾î ¹× ÃÖÀûÈµÈ Àåºñ »ç¿ëÀ» À§Çؼ PoE·Î Àü·ÂÀ» °ø±Þ ¹ÞÀº ÀåºñµéÀÇ Àü¿ø ¿Â/¿ÀÇÁ ŸÀÓ ½ºÄÉÁÙ¸µÀÌ °¡´ÉÇÑ PoE ŸÀÌ¸Ó ±â´É - Energy Efficient Ethernet(IEEE802.3az)¸¦ ÅëÇØ ¿¡³ÊÁö Àý¾à ¹× OPEX °¨¼Ò
º¸´Ù ¼Õ½¬¿î ³×Æ®¿öÅ© ¼³Ä¡ - ¼Õ½¬¿î VoIP ¼³Ä¡¸¦ À§ÇÑ Auto Voice VLAN - IP °¨½Ã ½Ã½ºÅÛÀÇ ¼Õ½¬¿î ¼³Ä¡¸¦ À§ÇÑ Auto Video - ³×Æ®¿öÅ© Á¢¼Ó ÄÁÆ®·ÑÀÇ ¼³Á¤À» À§ÇÑ °£ÆíÇÑ °¡À̵åÀÎ ACL ¸¶¹ý»ç - ´Ù¼öÀÇ ½ºÀ§Ä¡ Ž»ö, ¹èÄ¡, ¸ð´ÏÅ͸µ ¹× Æß¿þ¾î ¾÷±×·¹À̵带 À§ÇÑ °·ÂÇÑ µµ±¸ÀÎ, ½º¸¶Æ® ÄÁÆ®·Ñ ¼¾ÅÍ - NMS300, NETGEAR Network Management SystemÀ» ÅëÇØ ¸ðµç NETGEAR ºñÁî´Ï½º Àåºñ¿Í µ¿½Ã¿¡ ¹èÄ¡ ¹× ÅëÇÕ °ü¸®°¡ °¡´É
'ºò IT'°¡ ¾Æ´Ñ '½º¸¶Æ® IT' - ´Ù¼öÀÇ ½ºÀ§Ä¡ ¹èÄ¡¸¦ À§ÇÑ À¥ ±â¹Ý °ü¸® GUI ȤÀº ½º¸¶Æ® ÄÁÆ®·Ñ ¼¾Å͸¦ ÅëÇÑ Æí¸®ÇÑ °ü¸® - ±âÁ¸ ³×Æ®¿öÅ©¿¡¼ ¾î¶°ÇÑ Ç¥ÁØ ±â¹Ý ÀåºñÇÏ°íµµ »óÈ£ ȣȯÀÌ °¡´ÉÇÑ Ç¥ÁØ ±â¹Ý ±â¼ú Áö¿ø - ³×Æ®¿öÅ©ÀÇ ¾ÈÁ¤¼º ¹× ½Å·Ú¼ºÀ» Çâ»ó½ÃÅ°´Â µà¾ó Æß¿þ¾î À̹ÌÁö - NETGEARÀÇ Æò»ý Çϵå¿þ¾î Ç°Áú º¸Áõ Á¦µµ·Î ÇâÈÄ ¼ºñ½º¿¡ ´ëÇÑ °ÆÁ¤ ÇØ¼Ò - Æí¸®ÇÑ A/S Á¤Ã¥ ¹× ³×Æ®¿öÅ© ±â¼ú »ó´ã
ÅëÇÕµÈ ³×Æ®¿öÅ© ¾îÇø®ÄÉÀ̼Ç
NETGEARÀÇ ÆнºÆ® ÀÌ´õ³Ý ½º¸¶Æ® ½ºÀ§Ä¡µéÀº SMBÀÇ ³×Æ®¿öÅ©¸¦ À§ÇÑ ÃÖ¼±ÀÇ ¼±ÅÃÀ̸ç ÅõÀÚ ´ëºñ ³ôÀº °¡Ä¡¸¦ Á¦°øÇÕ´Ï´Ù.
- ºñ¿ë È¿À²ÀûÀÎ ÆнºÆ® ÀÌ´õ³Ý
- ³×Æ®¿öÅ© ¹éº» ¹× ¼¹ö¿ÍÀÇ Á¢¼Ó¿¡ ÇÊ¿äÇÑ ¾ÈÁ¤ÀûÀÎ ´ë¿ªÆø Áö¿øÀ» À§ÇÑ ±â°¡ºñÆ® ¾÷¸µÅ©
- Æ®·¡ÇÈ °ü¸® ±â´ÉÀ» ÅëÇØ ³×Æ®¿öÅ© ÇϴܱîÁö ÀÎÅÚ¸®ÀüÆ®ÇÑ ¼º´ÉÀ» Áö¿øÇÏ´Â ºñ¿ë È¿À²ÀûÀÎ ½º¸¶Æ® ½ºÀ§Ä¡
- Voice, video ¹× WLANÀ» ÇϳªÀÇ ¶È°°Àº ÅëÇÕ Ç÷§Æû¿¡¼ ¼Õ½±°í °£ÆíÇÏ°Ô ¹èÄ¡°¡ °¡´ÉÇÑ ³ôÀº È°¿ë¼º º¸Àå
- Æò»ý Ç°Áú º¸Áõ ¹× öÀúÇÑ »çÈÄ Áö¿ø ¼ºñ½º
1
.
±â¼ú »ç¾ç
Model |
FS526Tv2 |
FS728TLP |
FS728TP |
FS750T2 |
10/100Mbps ports |
24 |
24 |
24 |
48 |
Gigabit ports |
2 |
2 |
4 |
2 |
SFP ports |
¡¡ |
2 |
2 |
¡¡ |
# of PoE ports |
¡¡ |
12 |
24 |
¡¡ |
Total PoE Power budget (Watts) |
¡¡ |
100 |
192 |
¡¡ |
Max MAC entries |
8K |
8K |
4K |
8K |
Buffer size |
4Mb |
4Mb |
1Mb |
2Mb |
EEE |
¡î |
¡î |
¡î |
¡¡ |
FAN |
0 |
1 |
1 |
0 |
Acoustic Noise Level @25C (dBA) |
0 |
30.7 |
38.1 |
0 |
MTBF |
334,168 hrs |
755,725 hrs |
237,497 hrs |
59,800 hrs |
L2 Services - VLANs |
VLAN (# Supported) |
128 |
128 |
128 |
64 |
IEEE 802.1Q VLAN Tagging |
Yes |
IP based VLANs |
Yes |
no |
MAC based VLANs |
Yes |
no |
Port- based VLAN |
No |
Yes |
Voice VLAN |
Based on phones OUI bytes (internal database, or user-maintained) or protocols (SIP, H323 and SCCP) |
no |
NetworkSecurity |
IEEE 802.1x Radius PortAccess
Authentication |
Yes |
No |
Guest VLAN |
Yes |
No |
RADIUS Accounting |
Yes |
No |
MAC lockdown by the number of MACs |
Yes |
No |
Dynamic learned entries per port |
600 |
600 |
128 |
¡¡ |
Static entiries per port |
20 |
20 |
20 |
¡¡ |
Network Storm Protection, DoS |
Yes¡¡ |
No |
Broadcast,Unicast,
MulticastDoSProtection |
Yes |
No |
DoS attacks |
Yes |
No |
IP-based ACLs |
Yes |
No |
MAC (Trusted MAC) |
Yes |
No |
L4 ACL |
Yes |
No |
Protected Port |
Yes |
No |
Model |
FS526Tv2 |
FS728TLP |
FS728TP |
FS750T2 |
L2 Services -Availability |
IEEE 802.3ad - LAGs |
Yes |
No |
LACP |
Yes ( (8 LAGS with max. of 8 members in each LAG)) |
6 LAGs with max of 8 memebers in each LAG |
Broadcast Storm Control |
Yes |
No |
IEEE 802.3x (Full Duplex and flow control) |
Yes |
IEEE 802.1D Spanning Tree Protocol |
Yes |
IEEE 802.1w Rapid Spanning Tree |
Yes |
IEEE 802.1s Multiple Spanning Tree |
No |
No |
Yes |
No |
BPDU Guard |
Yes |
No |
DoS Prevention |
Yes |
No |
PoETimer |
¡¡ |
Yes |
Yes |
¡¡ |
L2 Services - MulticastFiltering |
IGMP Snooping (v1, v2 and v3) |
Yes |
No |
Max. Multicast Group |
128 |
128 |
512 |
¡¡ |
IGMP Snooping queries |
Yes |
No |
Block unknown Multicast |
Yes |
No |
L3 Services -DHCP |
DNS Client |
No |
No |
Yes |
No |
DHCP Filtering |
Yes |
No |
Network Monitoring and DiscoveryServices |
802.1ab LLDP and LLDP-MED |
Yes |
No |
SNMP |
V1, V2,V3 |
v1 and v2 |
RMON 1,2,3,9 |
Yes |
No |
ifTable |
Yes |
Quality of Service (QoS) |
Number of Priority Queues |
8 |
8 |
8 |
4 |
TCP/UDP-baesd QoS |
No |
No |
Yes |
No |
Rate limiting |
Yes |
Yes |
Egress only |
No |
DiffServ QoS |
No |
No |
Yes |
No |
IEEE 802.1p COS |
Yes |
DstMAC and IP |
Yes |
No |
IPv4 DSCP |
Yes |
No |
IPv4 TOS |
Yes |
Yes |
No |
No |
Model |
FS526Tv2 |
FS728TLP |
FS728TP |
FS750T2 |
Strick, or WRED (Weighted Deficit Round Robin) |
Both |
WRR |
Auto-VoIP |
Yes, based on protocols (SIP, H323 and SCCP) or on OUI bytes (default database and user-based OUIs) in the phone source MACaddress |
No |
Auto Video |
Yes |
No |
Port Mirroring (ingress and egress) |
Yes |
IEEE NetworkProtocols |
IEEE 802.3 Ethernet |
IEEE 802.3z Gigabit Ethernet1000BASE-SX/LX |
IEEE 802.1D Spanning Tree (STP) |
IEEE 802.3i 10BASE-T |
IEEE 802.3adTrunking(LACP) |
IEEE 802.1s Multiple Spanning Tree (MSTP) |
IEEE 802.3u 100BASE-T |
IEEE 802.1AB LLDP with ANSI/TIA-1057 (LLDP-MED) |
IEEE 802.1w Rapid Spanning Tree (RSTP) |
IEEE 802.3ab 1000BASE-T |
IEEE 802.1p Class ofService |
IEEE 802.1X Radius network accesscontrol |
IEEE 802.1Q VLAN Tagging |
IEEE 802.3af(PoE) |
|
IEEE 802.3x full-duplex flowcontrol |
|
|
Management |
Password management |
Yes |
Configurable Management VLAN |
Yes |
no |
Admin access control via Radius and TACACS+ |
No |
No |
Yes |
No |
Web-based graphical user interface (GUI) |
Yes |
Smart Control Center (SCC) for multi-switch management |
Yes |
Dual Software (firmware) image |
Yes |
No |
Dual Configuration file |
Yes |
No |
Cable Test utility |
Yes |
No |
File transfers (uploads, downloads) |
TFTP /HTTP |
No |
HTTP Download (firmware) |
Yes |
No |
LEDs |
Per port |
Speed, Link,Activity |
Per device |
Power, Fan andPoEPower Status (PoEmodel only) |
PhysicalSpecifications |
Weight (kg) |
1.35 |
2.92 |
3.57 |
3.2 |
Dimensions (WxDxH) mm |
326x168x43 |
440x204x43 |
440x257x43 |
440x205x43 |
Power Consumption (when all ports used, line-rate traffic and maxPoEif applicable) |
Worst case, all ports used, line-rate traffic, max PoE |
12w |
124w |
256w |
19.65w |
Model |
FS526Tv2 |
FS728TLP |
FS728TP |
FS750T2 |
EnvironmentalSpecifications |
Operating: |
Operating Temperature |
32¡Æ to 122¡ÆF (0¡Æ to 50¡ÆC) |
Humidity |
90% maximum relative humidity, non-condensing |
Altitude |
10,000 ft (3,000 m)maximum |
Storage: |
Storage Temperature |
– 4¡Æ to 158¡ÆF (–20¡Æ to 70¡ÆC) |
Humidity |
95% maximum relative humidity, non-condensing |
Altitude |
10,000 ft (3,000 m)maximum |
Electromagnetic Emissions andImmunity |
Certifications |
CE mark, commercial |
FCC Part 15 Class A, VCCI Class A |
Class A EN 55022 (CISPR 22) Class A |
Class A C-Tick |
EN 50082-1 |
EN55024 |
CCC |
Safety |
Certifications |
CE mark, commercial |
CSA certified (CSA 22.2 #950) |
UL listed (UL 1950)/cUL IEC 950/EN60950 |
Warranty andSupport |
ProSafe Lifetime Warranty¢Ó |
Included,lifetime |
ProSupportLifetime 24x7 Advanced
TechnicalSupport* |
Included, OneYear |
PackageContent |
All models |
ProSafe¢ç Fast Ethernet Smart Switch |
¡¡ |
Power cord |
¡¡ |
Rack-mounting kit |
¡¡ |
Resource CD with links to online documentation, installation guides, Web-management user manual, Smart Control Center (SCC) software and user guide. |
Optional Modules andAccessories |
AFM735 |
100Base-FX SFP GBIC (Multimode) |
AGM731F |
1000Base-SX SFP GBIC (Multimode) |
AGM732F |
1000Base-LX SFP GBIC (Single mode) | |