¾÷°è ÃÖÃÊÀÇ 10 ±â°¡ºñÆ® Áö¿ø ½º¸¶Æ® ½ºÀ§Ä¡
±Þ¼Óµµ·Î Áõ°¡ÇÏ´Â 10±â°¡ºñÆ® ¼¹ö¿ÍÀÇ È¯»óÀÇ Á¶È, NETGEAR ProSafe¢ç 52 port Gigabit Stackable Smart Switch´Â µ¥ÀÌÅÍ º¹»ç ¹× ¹é¾÷, °¡»óÈ, Video on Demand ¹× ´ë¿ë·® Àü¼Û ÇÁ·Î¼¼½Ì µî°ú °°Àº ³ôÀº ´ë¿ªÆøÀ» ¿ä±¸ÇÏ´Â SMB ³×Æ®¿öÅ© ȯ°æ¿¡¼ ÃÖ´ëÀÇ throughputÀ» º¸ÀåÇϱâ À§ÇØ 10 ±â°¡ºñÆ® Á¢¼ÓÀ» Áö¿øÇÏ´Â ¾÷°è ÃÖÃÊÀÇ ½º¸¶Æ® ½ºÀ§Ä¡ÀÔ´Ï´Ù.
±âÁ¸ ¸Å´ÏÁöµå ½ºÀ§Ä¡ ´ëºñ ¹Ý°ªÀÇ ºñ¿ëÀ¸·Î ProSafe 52 Port Gigabit Smart Switch´Â µðÁöÅÐ Àåºñ ¿¬°áÀ» À§ÇÑ 48°³ÀÇ ±â°¡ºñÆ® Æ÷Æ®¿Í ¼¹ö·ÎÀÇ ¾÷¸µÅ©, ȤÀº ½ºÅÂÅ·À» À§ÇÑ 4°³ÀÇ 10GE SFP+ Æ÷Æ®µéÀ» Á¦°øÇÕ´Ï´Ù. ÃÖ´ë 6´ëÀÇ ½ºÀ§Ä¡µéÀ» ½ºÅÃÇÔÀ¸·Î½á ÅäÅ» 288°³ÀÇ ³×Æ®¿öÅ© Æ÷Æ®µéÀ» Á¦°ø ¿ùµîÇÑ ½Å·Ú¼ºÀ» À§ÇÑ Ç® ¸®´ø´ø½Ã¸¦ º¸ÀåÇÕ´Ï´Ù. GS752TXS´Â °í±Þ Æ®·¡ÇÈ °ü¸® ¹× º¸¾È ±â´É µîÀ» Æ÷ÇÔÇÑ Ç³ºÎÇÑ ¿£ÅÍÇÁ¶óÀÌÁî±Þ ±â´ÉÀ» Á¦°øÇϸç À¥ ±â¹ÝÀÇ ±×·¡ÇÈ À¯Àú ÀÎÅÍÆäÀ̽º¸¦ ÅëÇØ º¸´Ù ¼Õ½¬¿î ¼³Á¤ ¹× ¸ð´ÏÅ͸µÀ» µµ¿ÍÁÝ´Ï´Ù.
¿£ÅÍÇÁ¶óÀÌÁî±Þ °ü¸® ±â´É dzºÎÇÑ Layer 2 °ü¸® ±â´ÉµéÀ» ÅëÇØ GS752TXS´Â ¹Ì·¡ ȯ°æ¿¡µµ ÀûÇÕÇÑ È¿À²¼º°ú ¾ÈÀü¼ºÀ» ¾à¼ÓÇÕ´Ï´Ù. Static RoutingÀº ÀÌ ½ºÀ§Ä¡¸¦ ÅëÇØ ³»ºÎ ¶ó¿ìÆÃÀ» °¡Áö°í ³×Æ®¿öÅ©¸¦ ¼¼±×¸ÕÆ® ÇÒ ¼ö ÀÖ°Ô µµ¿ÍÁÖ¸ç ¶ó¿ìÅÍ´Â ¿ÀÁ÷ ¿ÜºÎ Æ®·¡ÇÈ ¶ó¿ìÆÿ¡ °ü¿©Çϵµ·Ï µµ¿ÍÁÖ¾î Àüü ³×Æ®¿öÅ©¸¦ ´õ¿í È¿À²ÀûÀ¸·Î ¸¸µé¾î ÁÝ´Ï´Ù. Dynamic VLAN ÁöÁ¤Àº Áö¼ÓÀûÀÎ Á¤Ã¥ ¹× ³×Æ®¿öÅ©¿¡ Á¢¼Ó °¡´ÉÇÑ »ç¿ëÀÚ¸¦ ½É¾îÁÜÀ¸·Î½á »ç¿ëÀÚ°¡ ¾îµð¿¡ Á¢¼ÓÇØ ÀÖµçÁö »ó°ü¾øÀÌ ³ôÀº º¸¾È ¼öÁØÀ» º¸ÀåÇÕ´Ï´Ù. MLD Snooping Áö¿øÀº ¸ðµç Æ÷Æ®µé¿¡¼ ¸ÖƼij½ºÆ® ÆÐŶµéÀ» »Ñ·ÁÁö±â º¸´Ù´Â ¿ÀÁ÷ ÁöÁ¤µÈ È£½ºÆ®¿¡°Ô¸¸ ¸ÖƼij½ºÆ® Æ®·¡ÇÈÀ» Àü´ÞÇÔÀ¸·Î½á ³×Æ®¿öÅ© È¿À²¼ºÀ» Áõ´ë½Ãų ¼ö ÀÖ½À´Ï´Ù. GS752TXS´Â Ç® IPv6 Áö¿øÀº ¹°·Ð ±¤¹üÀ§ÇÑ º¸¾È ±â´É, °í±Þ ¸ÖƼij½ºÆ® °ü¸® ±â´É µîÀ» Á¦°øÇÕ´Ï´Ù.
³ôÀº ½Å·Ú¼º, Æí¸®ÇÑ È®À强 GS752TXS´Â ºñÁî´Ï½º¿Í ÇÔ²² ¼ºÀåÇÒ ¼ö ÀÖ´Â È®Àå °¡´É ¼Ö·ç¼Ç ÀÔ´Ï´Ù. ÇÑ´ëÀÇ ½ºÀ§Ä¡¿¡¼ Ãâ¹ßÇÏ¿© ÃÖ´ë 6´ëÀÇ ½ºÀ§Ä¡±îÁö ½ºÅÃÀÌ °¡´ÉÇÏ¿© ÃÑ 288°³ÀÇ ³×Æ®¿öÅ© Æ÷Æ®¸¦ Á¦°øÇÒ ¼ö ÀÖ½À´Ï´Ù. °¢ ½ºÀ§Ä¡¿¡ ÀÖ´Â 4°³ÀÇ 10 ±â°¡ºñÆ® SFP+ Æ÷Æ®µé Áß 2°³´Â ±× ½ºÅÃÀ» À§ÇØ »ç¿ë °¡´ÉÇϸç ÃÖ´ë 40GbpsÀÇ ½ºÅÂÅ· backplaneÀ» °¡Áø ÇϳªÀÇ logical unitÀÎ ÇϳªÀÇ ½ºÀ§Ä¡·Î ¼³Á¤ ¹× °ü¸®°¡ °¡´ÉÇÏ¿© ¼Õ½¬¿î ¹èÄ¡¿Í À¯Áö °ü¸®ÀÇ Æí¸®¼ºÀ» ¸¸³£ÇÒ ¼ö ÀÖ½À´Ï´Ù. ½ºÅÃµÈ ½ºÀ§Ä¡µéÀº SFP+ Fiber optic Á¢¼ÓÀ» »ç¿ëÇÔÀ¸·Î½á ´Ù¼öÀÇ ¹°¸®ÀûÀÎ Àå¼Ò¿¡ ¶³¾î¶ß·Á ¹èÄ¡ÇÏ´Â °Ô °¡´ÉÇÏ¿© ¿ø°ÝÁö ȤÀº Áö»ç¿¡¼ »ç¿ëÇϴµ¥ ÀÌ»óÀûÀÎ ¼Ö·ç¼ÇÀÔ´Ï´Ù. ¸ðµç 4°³ÀÇ 10GE Æ÷Æ®µéÀº ¼¹ö ¹× ½ºÅ丮Áö Àåºñ¿ÍÀÇ ¾÷¸µÅ© Á¢¼ÓÀ» À§ÇØ »ç¿ëÇÒ ¼ö ÀÖÀ¸¸ç, ȤÀº 2°³´Â ±Ù°Å¸® ȤÀº ¿ø°Å¸® ½ºÅÂÅ·À» À§ÇØ ³ª¸ÓÁö 2°³´Â ¾÷¸µÅ© ȤÀº Link aggregationÀ» À§ÇØ ºÐ¸®Çؼ »ç¿ëÀÌ °¡´ÉÇÕ´Ï´Ù. Auto Failover ±â´ÉÀº ½ºÅà »ó¿¡ ÀÖ´Â ÇϳªÀÇ ½ºÀ§Ä¡°¡ °íÀå ½Ã¿¡µµ ¸ðµç ´Ù¸¥ ½ºÀ§Ä¡µéÀÌ ¿µÇâÀ» ¹ÞÁö ¾Êµµ·Ï ¾ÈÀüÇÑ ³×Æ®¿öÅ© ÀÛµ¿À» º¸ÀåÇØ ÁÝ´Ï´Ù.
À¯¿¬ÇÑ ¸Å´ÏÁö¸ÕÆ® ¿É¼Ç "Smart" Switch·Î¼ IT°ü¸®ÀÚµéÀº GS752TXS¸¦ ¾î¶»°Ô °ü¸®ÇÒ °Í ÀÎÁö¸¸À» °áÁ¤ÇÏ¸é µË´Ï´Ù. °¢°¢ÀÇ ½ºÀ§Ä¡µéÀº ¸ðµÎ ÇϳªÀÇ °£ÆíÇÑ À¥ ±â¹Ý ±×·¡ÇÈ À¯Àú ÀÎÅÍÆäÀ̽º¸¦ ÅëÇØ °ü¸®µÉ ¼ö ÀÖ½À´Ï´Ù. GS752TXS´Â ¶ÇÇѱâÁ¸ SNMP ±â¹Ý ÄְܼúÀÇ È£È¯¼ºÀ» À§ÇØ SNMP ¼ÒÇÁÆ®¿þ¾î¸¦ ÅëÇØ °ü¸®µÉ ¼öµµ ÀÖ½À´Ï´Ù. º¸´Ù Å« ³×Æ®¿öÅ©¸¦ À§Çؼ NETGEARÀÇ Smart Control Center´Â ¹«·á Windows ±â¹Ý ¾îÇø®ÄÉÀ̼ÇÀ» Á¦°ø ³×Æ®¿öÅ© »ó¿¡ ÀÖ´Â ¸ðµç ½º¸¶Æ® ½ºÀ§Ä¡µéÀ» ŽÁöÇÏ°í, ¼³Á¤Çϸç, ¾÷±×·¹À̵åÇÒ ¼ö ÀÖ½À´Ï´Ù. ½ºÀ§Ä¡, ¹«¼± AP, NAS¿Í °°ÀÌ NETGEAR¿¡¼ ³ª¿À ¸ðµç ³×Æ®¿öÅ© ÀåºñµéÀº NETGEAR Network Management System(NMS-200)À» ÅëÇØ ±¤¹üÀ§ÇÑ °ü¸®¿Í ÅëÁ¦, ¼Õ½¬¿î ¸ð´ÏÅ͸µ ¹× ¿ÀÅ亣À̼ÇÀ» ÇϳªÀÇ ÄַܼΠÁ¦¾îµÉ ¼ö ÀÖ½À´Ï´Ù.
Çϵå¿þ¾î ÁÖ¿ä ±â´É |
Àå Á¡ |
10 ±â°¡ºñÆ® Á¢¼Ó |
10GE ¼¹öµéÀÇ °·ÂÇÑ ÆÄ¿ö Áö¿ø
µ¥ÀÌÅÍ ¹é¾÷ ¹× º¹»ç, °¡»óÈ, VoD ´ë¿ë·® Àü¼Û ÇÁ·Î¼¼½Ì µî ³ôÀº ´ë¿ªÆø ¾îÇø®ÄÉÀÌ¼Ç Áö¿ø |
ÃÖ´ë 6´ë ½ºÀ§Ä¡ ½ºÅà |
¿£ÅÍÇÁ¶óÀÌÁî¿Í ÇÔ²² ¼ºÀåÀÌ °¡´ÉÇÑ È®Àå°¡´ÉÇü ½ºÀ§Ä¡
½ºÅÃ»ó¿¡ ÀÖ´Â ½ºÀ§Ä¡ Çϳª°¡ °íÀ峪µµ ³ª¸ÓÁö ½ºÀ§Ä¡¿£ ¿µÇâÀ» ÁÖÁö ¾Ê´Â Auto Failover ±â´É |
4°³ 10GE SFP+ ½ºÅÂÅ·/¾÷¸µÅ© Æ÷Æ® |
ÃÖ´ë 40 Gbps stacking backplane
Fiber optic Á¢¼ÓÀ» ÅëÇØ ½ºÀ§Ä¡µéÀº ¿ø°Ý ȤÀº Áö»ç¿Í °°Àº ´Ù¼öÀÇ ¹°¸®Àû Àå¼Ò¿¡ ¹èÄ¡ °¡´É |
¼ÒÇÁÆ®¿þ¾î ÁÖ¿ä ±â´É |
Àå Á¡ |
Dynamic VLAN ÁöÁ¤ |
»ç¿ëÀÚÀÇ À§Ä¡¿¡ »ó°ü¾øÀÌ Áö¼ÓÀûÀÎ Á¤Ã¥°ú ³×Æ®¿öÅ© Á¢¼Ó »ç¿ëÀÚ Çã°¡¸¦ ºÎ¿©ÇÔÀ¸·Î½á º¸¾È °È |
MLD snooping |
¸ðµç Æ÷Æ®µé¿¡°Ô ¸ÖƼij½ºÆ® ÆÐŶÀ» Àü¼ÛÇϱ⺸´Ù´Â ÁöÁ¤µÈ È£½ºÆ®¿¡°Ô¸¸ ¸ÖƼij½ºÆ® Æ®·¡ÇÈÀ» Àü¼ÛÇÔÀ¸·Î½á ³×Æ®¿öÅ© È¿À²¼º Áõ´ë |
IPv6 Ç® Áö¿ø |
Â÷¼¼´ë ¾îÇø®ÄÉÀÌ¼Ç ¹× È®Àå ¹öÀüÀ» ¸ðµÎ Áö¿øÇϵµ·Ï ¹Ì·¡ ÁöÇâ ³×Æ®¿öÅ©·Î ITÅõÀÚºñ¿ë Àý¾à |
DHCP snooping |
IP-to-MAC binding Á¤º¸¸¦ È°¿ëÇÔÀ¸·Î½á DHCP ¼¹ö °ø°Ý°ú °°Àº Access Layer Attack, ARP man-in-the-middle attacks ¹× IP/MAC spoofing attacks µî ¿¹¹æ |
Æ÷Æ® º¸È£ |
°°Àº ½ºÀ§Ä¡ »ó¿¡¼µµ ƯÁ¤ Æ÷Æ®µéÀ» ´Ù¸¥ Æ÷Æ®µé°ú Ä¿¹Â´ÏÄÉÀÌ¼Ç Â÷´ÜÀ» ÅëÇØ º¸¾È °È
Áß¿äÇÑ ¼ºñ½º ¹× Á¤º¸ ½ÀµæÀ» À§ÇØ °ø°ÝÀÚµéÀÇ ½Ã½ºÅÛ ½ºÄ³´× ¹æÁö |
NETGEAR Network Management System (NMS200) |
½ºÀ§Ä¡, ¹«¼±Àåºñ, NAS µî ±¤¹üÀ§ÇÑ NETGEAR ÀåºñµéÀ» ¼Õ½±°Ô ÅëÁ¦, °ü¸®, ¼³Á¤ ¹× ÀÚµ¿È °¡´É |
Network Protocol and Standards Compatibility
- IEEE 802.3 10BASE-T
- IEEE 802.3u 100BASE-TX
- IEEE 802.3ab 1000BASE-T
- IEEE 802.3z 1000BASE-X
- IEEE 802.3x full-duplex flow control
- IEEE802.3aq (10GBASE-LRM)
- IEEE802.3ae (10Gbase Ethernet
- IEEE802.3az (EEE)
Interfaces
- 48 10/100/1000 Mbps switching ports
- 4-10Gbps SFP+ slots (port 49~52) to support 10GEbps optical module and 1G optical module
- Port 51 and port 52 can be used as the stacking ports or as uplink ports.
- Auto-sensing and auto-negotiating capabilities for all copper ports
- Auto Uplink¢â on all ports to make the right connection
Administrative Switch Management
- IEEE 802.1Q VLAN (256 groups, Static)
- IEEE 802.1p Class of Service (CoS)
- 8 hardware queues
- Port-based QoS
- IEEE 802.3ad Static or Dynamic Link Aggregation (LACP)
- IEEE 802.1D Spanning Tree Protocol
- IEEE 802.1w Rapid Spanning Tree Protocol
- IEEE 802.1s Multiple Spanning Tree Protocol
- SNMP v1, v2c, v3
- RFC 1213 MIB II
- RFC 1643 Ethernet Interface MIB
- RFC 1493 Bridge MIB
- RFC 2131 DHCP client
- IEEE 802.1x (RADIUS)
- IEEE 802.1x Dynamic VLAN Assignment
- HTTPS/SSL: Secure HTTP GUI
- RADIUS accounting
- Layer 3 (DSCP) Quality of Service (QoS)
- TACACS+
- Port-based security by locked MAC addresses
- TCP/UDP-based priority mapping
- GMP snooping v1, v2, v3
- MLD Snooping
- ACLs (MAC, IPv4, IPv6 and TCP/UDP based)
- Storm control for broadcast, multicast and unknown unicast packets
- Port-based ingress/egress rate limiting
- SNTP
- DNS
- DoS and Auto DoS prevention
- IPv6 management, multicast and QoS
- Static Routing
- DHCP Snooping
- Green Features: Lower power consumption during link-down or idle mode or with shorter cable length.
- Protocol and MAC based VLAN
- RMON group 1, 2, 3, 9
- Private Enterprise MIB
- Port mirroring – many-to-one
- IEEE 802.3ab LLDP
- LLDP-MED
- Protected ports
- Cable test
- Smart Control Center discovery
- Web-based configuration
- Configuration backup/restore
- Password access control
- Firmware upgradeable
Performance Specifications
- Forwarding modes: Store-and-forward
- Bandwidth: 176 Gbps
- Stacking up to 6 switches or 300 ports per stack
- Stacking bandwidth: 20 Gbps
- Network latency: Less than 20 microseconds for 64-byte frames in store and forward mode for 1000 Mbps to 1000 Mbps transmission
- Buffer memory: 2 MB
- 128Mbytes System DDR SDRAM (32Mbx16).
- 32Mbytes Flash size.
- Address database size: 16K media access control (MAC) addresses per system
- Addressing: 48-bit MAC address
- 256 VLANs; Maximum VLAN id is 4093
- 7 802.1p traffi c classes
- 8 LAGs
- 32 static routes
- 15 routed VLANs
- 1024 ARP Cache entries
- 7 queues used for DiffServ
- 100 ACLs (IPv4/IPv6)
- 8K DHCP snooping binding
- 1024 DHCP static entries
- Mean time between failures (MTBF):
– 256,119 hours (~29.3 years) at 25 ¡ÆC – 90,993 hours (~10.3 years) at 55 ¡ÆC
LEDs
- Unit: Power, master, stack ID, FAN
- Per port: Link, speed, activity
Power Supply
- Max Power consumption: 77W
- 100-240V AC/50-60 Hz universal input
Physical Specifications
- Dimensions: (h x w x d): 43 x 440 x 257 mm (1.69 x 17.32 x 10.13 in)
- Weight: 4.50 kg (9.92 lb)
Environmental Specifications
- Operating temperature: 32¡Æ to 104¡Æ F (0¡Æ to 50¡Æ C)
- Storage temperature: -4¡Æ to 158¡Æ F (-20¡Æ to 70¡Æ C)
- Operating humidity: 95% maximum relative humidity, non-condensing
- Storage humidity: 95% maximum relative humidity, non-condensing
- Operating altitude: 10,000 ft (3,000 m) maximum
- Storage altitude: 10,000 ft (3,000 m) maximum
Electromagnetic Compliance
- CE mark, commercial
- FCC Part 15 Class A
- VCCI Class A
- EN 55022 (CISPR 22),
- EN 55024 (CISPR 24)
- C-Tick
Safety
- CE mark, commercial
- CUL 60950 (Listed)/EN 60950 (Low Voltage Directive)
System Requirements
- Category 5 UTP Network cables or better
- Network card for each PC
- Network software (e.g., Windows7)
Warranty
- NETGEAR Lifetime Warranty¢Ó
ProSupport Service Packs Available
- OnCall 24x7, Category 2
- - PMB0332-100 (US)
- - PMB0332 (non-US)
- XPressHW, Category 2
- - PRR0332
Package Contents
- ProSafe¢ç 52-Port Gigabit Stackable Smart Switch with 10G uplinks
- Rubber footpads
- Power cord
- Rack-mount kit
- Resource CD installation guide
- Warranty/support information card
Modules
- AXM761 ProSafe 10GBASE-SR SFP+ GBIC
- AXM762 ProSafe 10GBASE-LR SFP+ GBIC
- AXM763 ProSafe 10GBASE-LRM SFP+ GBIC
- AXC761 1m Direct Attach SFP+ Cable
- AGM731F ProSafe 1000BASE-SX SFP GBIC: Module with LC connectors for 50um or 62.5um multi-mode fiber cable
- AGM732F ProSafe 1000BASE-LX SFP GBIC: Module with LC connectors for 9um single-mode fiber cable
- AGM733 ProSafe
Ordering Information
- North America: GS752TXS-100NAS
- Korea, Europe: GS752TXS -100EUS
- Asia/Japan: GS752TXS -100AJS
|