|
ºñ¿ë È¿À²ÀûÀÎ 10GBase-T Ä¿³Ø¼Ç°ú °í±Þ L2+ °ü¸® ±â´ÉÀ» ³»ÀåÇÑ SMB¸¦ À§ÇÑ ¾÷°è ÃÖÃÊÀÇ 10G ½º¸¶Æ® ½ºÀ§Ä¡
SMB¿ë ³×Æ®¿öÅ© ÀåºñÀÇ ¼±µÎ ºê·£µå NETGEAR´Â SMB °í°´µé¿¡°Ô ¾ó¸¶¸¸Å ³ôÀº ½Å·Ú¼ºÀ» Áö´Ñ °í¼º´É ³×Æ®¿öÅ©°¡ Áß¿äÇÑÁö¸¦ ÀÌÇØÇÏ°í ÀÖ½À´Ï´Ù. VoIP, ºñµð¿À ½ºÆ®¸®¹Ö, IP °¨½Ã ½Ã½ºÅÛ°ú °°Àº °¡»óÈ È¯°æ, Ŭ¶ó¿ìµå ±â¹Ý ¼ºñ½º ¹× ¾îÇø®ÄÉÀÌ¼Ç µîÀÇ µµÀÔÀ¸·Î SMB ³×Æ®¿öÅ©ÀÇ ¿ä±¸»çÇ×ÀÌ ´Ü¼øÇÑ ¾ÈÁ¤¼ºÀ» ³Ñ¾î¼ º¸´Ù ºü¸¥ ¼Óµµ¿Í ´õ ³ªÀº ÆÛÆ÷¸Õ½º µî ÇÑÃþ º¹ÀâÇØÁö°í ´Ù¾çÇØ Áö°í ÀÖ½À´Ï´Ù. NETGEARÀÇ 10G ½º¸¶Æ® ½ºÀ§Ä¡ XS712T´Â 10Gbase-T ±â¼úÀ» »ç¿ëÇÔÀ¸·Î½á non-blocking 10 ±â°¡ºñÆ® ´ë¿ªÆøÀ» È¿À²ÀûÀÎ ºñ¿ëÀ¸·Î Á¦°øÇÒ ¼ö ÀÖ´Â ÀÌ»óÀûÀÎ ¼Ö·ç¼ÇÀ» Áö¿øÇÕ´Ï´Ù.
NETGEAR XS712T´Â 12°³ÀÇ 10GBase-T copper Æ÷Æ®¿Í 10G ±¤ ¸µÅ©¸¦ À§ÇÑ 2°³ÀÇ ÄÞº¸ SFP+¸¦ Áö´Ñ °·ÂÇÑ ½º¸¶Æ® ½ºÀ§Ä¡ÀÔ´Ï´Ù. ÀÌ Á¦Ç°Àº 10G Áö¿ø °¡´ÉÇÑ ¼¹ö ¹× NAS(Network Attached Storage)¿¡ 10G Ä¿³Ø¼ÇÀ» Á¦°øÇÏ´Â °¡Àå ºñ¿ë È¿À²ÀûÀÎ ¼Ö·ç¼ÇÀ¸·Î µðÀÚÀεǾú½À´Ï´Ù. 10G ¸Å´ÏÁöµå ½ºÀ§Ä¡(XSM7224)·Î ¾÷¸µÅ© ½Ãų ¼ö ÀÖ´Â 10G Á¢¼Ó ½ºÀ§Ä¡·Î »ç¿ëÇÒ ¼ö ÀÖÀ¸¸ç µ¿½Ã¿¡ 10G Ä¿³Ø¼ÇÀ» ÅëÇØ ÇÏ´Ü Àåºñ¿ÍÀÇ ¿¬°áµµ °¡´ÉÇÕ´Ï´Ù.
ÇÏÀ̶óÀÌÆ®
XS712T´Â °¡»óÈ, ÅëÇÕ ³×Æ®¿öÅ©, ¸ð¹ÙÀÏ È¯°æÀ» À§ÇØ ÇÊ¿äÇÑ ÇöÀç ȤÀº ¹Ì·¡¿¡ »ç¿ë °¡´ÉÇÑ Æ÷°ýÀûÀÎ L2 °ü¸® ±â´ÉÀ» Á¦°øÇÕ´Ï´Ù. ±× ÁÖ¿ä ±â´ÉµéÀº ¾Æ·¡¿Í °°½À´Ï´Ù.:
- VLAN ¹× °Ô½ºÆ® VLAN°ú °°Àº °í±Þ VLAN ±â´É
- L2-L4 ÀÎ½Ä ¹× 8°³ priority¸¦ Áö¿øÇÏ´Â °í±Þ QoS(Quality os Service) ±â´É
- Static Routing
- Private VLAN
- Dynamic VLAN ÁöÁ¤
- IGMP and MLD snooping
- Advanced Security
- °ü¸®, QoS ¹× ACL¸¦ À§ÇÑ IPv6
Base-T¸¦ Áö´Ñ 10 Gigabit·ÎÀÇ ÀÌÀü
- ´Ù¸¥ Base-T ±â¼ú°ú °°Àº 10GBase-T´Â Ç¥ÁØ RJ45 ÀÌ´õ³Ý ÀèÀ» »ç¿ë
- °í¼Ó ¹× Àú¼Ó ¸ðµÎ¿¡¼ ȣȯ ¹× ÀÚµ¿ negotiation Áö¿øÀ¸·Î ¸ðµç Àåºñ¸¦ ÇѲ¨¹ø¿¡ ´Ù ¾÷±×·¹À̵åÇÒ ÇÊ¿ä ¾øÀ½
- Cat5/Cat5E´Â ±â°¡ºñÆ® ¼Óµµ Áö¿ø : Cat6 twisted pair copper cablingÀº ÃÖ´ë 30¹ÌÅͱîÁö°¡ 10±â°¡ºñÆ®¸¦ À§ÇÑ ÃÖ¼Ò ¿ä±¸»çÇ×ÀÓ
- Cat6A ȤÀº »õ·Î¿î Cat7 cablingÀº ÃÖ´ë 100¹ÌÅÍ 10GBase-T Ä¿³Ø¼ÇÀ» Áö¿øÇÔ
- SMB ³×Æ®¿öÅ©¸¦ À§ÇÑ Core ½ºÀ§Ä¡·Î È°¿ë
- 10G Áö¿ø °¡´É ¼¹ö ¹× ³×Æ®¿öÅ© ½ºÅ丮Áö·Î 10G ¿¬°á
- °·ÂÇÑ L2/L2+ ±â´ÉµéÀº SMBÀÇ °¡»óÈ È¯°æÀ» À§ÇØ °¡Àå ºñ¿ë È¿À²ÀûÀÎ ÇÙ½É ½ºÀ§Ä¡·Î È°¿ëÀÌ °¡´É
- 10G ´ë¿ªÆø, °í±Þ Æ®·¡ÇÈ °ü¸® ±â´É ¹× Æ÷°ýÀûÀÎ IPv6 Áö¿øÀº ÇâÈÄ ±Í»çÀÇ ³×Æ®¿öÅ© ¾÷±×·¹À̵带 À§ÇÑ ¾È¼º¸ÂÃã
- Static routingÀº º¸´Ù È¿À²ÀûÀÎ ³×Æ®¿öÅ© ¸®¼Ò½º È°¿ëÀ» À§ÇØ ³»ºÎ Æ®·¡ÇÈÀ» ¶ó¿ìÆÃÇÒ ¼ö ÀÖÀ½
- IGMP ¹× MLD snoopingÀº °í±Þ ¸ÖƼij½ºÆ® ÇÊÅ͸µ Á¦°ø
Çϵå¿þ¾î »ìÆ캸±â
|
Àü¸é |
Èĸé |
Model Name |
Form-Factor |
100/1000/10GBase-T |
1000/10GBase-X |
Power Supply |
Fans |
XS712T |
Rackmount |
12 |
2 (shared) |
1 internal PSU, fixed |
2 internal, fixed fans |
¼ÒÇÁÆ®¿þ¾î »ìÆ캸±â
|
LAYER 2+ |
Management |
IPv4 / IPv6 ACL and QoS |
IPv4 / IPv6 Multicast filtering |
Auto-VoIP |
EEE (802.3az) Auto-EEE |
VLANs |
Convergence |
IPv4 Unicast Static Routing |
WXS712T |
L2, L3, L4 ingress |
IGMP and MLD Snooping |
Yes |
Yes |
Static, Dynamic, Voice, MAC, Protocol-based, Private VLANs |
LLDP-MED, RADIUS, 802.1X |
Yes (VLANs) |
ÆÛÆ÷¸Õ½º »ìÆ캸±â
Model Name |
Packet buffer |
CPU |
ACLs |
MAC address table RP/NDP table VLANs |
Fabric |
Latency |
Static Routes |
Multicast IGMP Group |
XS712T |
2Mb |
600 Mhz 128M RAM 32M Flash |
100 ingress |
32K MAC 1K ARP/NDP VLANs: 256 |
240Gbps line-rate |
10GBase-T <6.606 ¥ìs SFP+ <2.979 ¥ìs |
32 IPv4 |
1K |
±â´É ¹× Ư¡ »ìÆ캸±â
Çϵå¿þ¾î Ư¡ |
Çý ÅÃ |
12 10GBase-T Ä¿³Ø¼Ç |
±âÁ¸ ÆнºÆ® ÀÌ´õ³Ý ¹× ±â°¡ºñÆ® ÀÌ´õ³Ý Á¦Ç°°ú ¿Ïº®ÇÑ È£È¯¼ºÀ» ÀÚ¶ûÇÏ¸ç ³·Àº Latency¿Í line-rate 10G Copper ¡°Base-T¡± ±â¼úÀ» Áö¿øÇÕ´Ï´Ù. ±âÁ¸ Cat6 RJ45À» »ç¿ëÇÏ¿© ´Ü°Å¸® Á¢¼Ó(ÃÖ´ë 300m)ÀÌ °¡´ÉÇϸç Cat6A/Cat 7À» »ç¿ëÇÏ¿© ÃÖ´ë 100m Á¢¼ÓÀÌ °¡´ÉÇÔÀ¸·Î½á ÇöÀç ³×Æ®¿öÅ©¸¦ 10G Áö¿ø ³×Æ®¿öÅ©·Î ºñ¿ë È¿À²ÀûÀ¸·Î ¾÷±×·¹À̵尡 °¡´ÉÇÕ´Ï´Ù. |
2 ÄÞº¸Çü SFP+ 10G ±¤ Æ÷Æ® |
±â°¡ºñÆ® ±¤°ú ȣȯÀÌ °¡´ÉÇϸç ÀÌ ±¤ ¸µÅ©¸¦ Áö¿øÇÏ´Â Aggregation ½ºÀ§Ä¡·Î ȤÀº 10G Áö¿ø °¡´É ÇÙ½É ½ºÀ§Ä¡·ÎÀÇ ¾÷¸µÅ© ¿ëµµ·Îµµ »ç¿ëÀÌ °¡´ÉÇÑ À¯¿¬¼ºÀ» Á¦°øÇÕ´Ï´Ù. |
¼ÒÇÁÆ®¿þ¾î Ư¡ |
Çý ÅÃ |
Dynamic VLAN ÁöÁ¤ |
IP Æù ¹× PCµéÀº ¸ðµÎ °°Àº Æ÷Æ®¿¡¼³ª ȤÀº ´Ù¸¥ VLAN ÁöÁ¤ Á¤Ã¥¿¡ ÀÇÇØ ÀÎÁõµÉ ¼ö ÀÖ½À´Ï´Ù. »ç¿ëÀÚµéÀº ³×Æ®¿öÅ© »ó¿¡¼ ¹°¸®ÀûÀÎ °ø°£¿¡ ±¸¾Ö ¾øÀÌ ³×Æ®¿öÅ© ÃþÀÇ °°Àº ·¹º§¿¡¼ À̵¿ÀÌ È°µ¿ÀÌ ÀÚÀ¯·Ó°Ô °¡´ÉÇÕ´Ï´Ù. |
Static Routing |
½ºÀ§Ä¡¸¦ ÅëÇؼ ³»ºÎ ¶ó¿ìÆÃÀ» °¡Áö°í ³×Æ®¿öÅ© ¼¼±×¸ÕÆ®¸¦ Á¦°øÇÏ´Â °¡Àå °£ÆíÇÑ ¹æ¹ý. ±× ¶ó¿ìÅÍ´Â ¿ÜºÎ Æ®·¡ÇÈÀÇ ¶ó¿ìÆø¸À» À§ÇØ »ç¿ëÇϵµ·Ï º¸ÀåÇϸç Àüü ³×Æ®¿öÅ©¸¦ ´õ È¿À²ÀûÀ¸·Î ¸¸µé¾î ÁÝ´Ï´Ù.IP Æù ¹× PCµéÀº ¸ðµÎ °°Àº Æ÷Æ®¿¡¼³ª ȤÀº ´Ù¸¥ VLAN ÁöÁ¤ Á¤Ã¥¿¡ ÀÇÇØ ÀÎÁõµÉ ¼ö ÀÖ½À´Ï´Ù. »ç¿ëÀÚµéÀº ³×Æ®¿öÅ© »ó¿¡¼ ¹°¸®ÀûÀÎ °ø°£¿¡ ±¸¾Ö ¾øÀÌ ³×Æ®¿öÅ© ÃþÀÇ °°Àº ·¹º§¿¡¼ À̵¿ÀÌ È°µ¿ÀÌ ÀÚÀ¯·Ó°Ô °¡´ÉÇÕ´Ï´Ù. |
°ü¸®, ACL, QoS¸¦ À§ÇÑ Æ÷°ýÀûÀÎ IPv6 Áö¿ø |
ÇöÀç ³×Æ®¿öÅ©¸¦ ¹Ì·¡¿¡µµ »ç¿ëÇÒ ¼ö ÀÖµµ·Ï °³¹ßµÇ¾î ÅõÀÚ ´ëºñ È¿°ú¸¦ ±Ø´ëÈ ÇÏ°í ÇâÈÄ ½ºÀ§Ä¡ ±³Ã¼ ¾øÀ̵µ IPv6 ±â¹Ý ³×Æ®¿öÅ©·ÎÀÇ À¯¿¬ÇÑ ¾÷±×·¹ÀÌµå °¡´É. |
Private VLAN |
Ãß°¡µÈ º¸¾ÈÀ¸·Î µû·Î µµ¿òÀÌ ÇÊ¿ä ¾ø´Â broadcast Áö¿ø |
IGMP Snooping ¹× MLD Snooping |
¸ÖƼij½ºÆ® ½ºÆ®¸²À» À§ÇÑ º¸´Ù ºü¸¥ receiver joins ¹× leave¸¦ ¿ëÀÌÇÏ°Ô ÇÕ´Ï´Ù. ¶ÇÇÑ º°µµÀÇ Ãß°¡ ¸ÖƼij½ºÆ® ¶ó¿ìÅÍ°¡ ÇÊ¿ä ¾øÀÌ ÁöÁ¤µÈ receiver¿¡ ¸ÖƼij½ºÆ® Æ®·¡ÇÈÀÌ µµ´ÞÇÒ ¼ö ÀÖµµ·Ï º¸ÀåÇÔÀ¸·Î½á ³×Æ®¿öÅ©ÀÇ È¿À²¼ºÀ» ³ôÀÌ°í ºñ¿ëÀ» Àý°¨ÇØ ÁÝ´Ï´Ù. |
öÀúÇÑ º¸¾È ±â´É:
- 802.1x ÀÎÁõ
- DHCP ÇÊÅ͸µ
- locked MAC¿¡ ÀÇÇÑ Æ÷Æ® ±â¹Ý º¸¾È
- MAC ¹× IP ÁÖ¼Ò¸¦ ±â¹ÝÀ¸·Î ÇÑ Æ®·¡ÇÈ Çã°¡ ¹× °ÅºÎ¸¦ À§ÇÑ ACL ÇÊÅ͸µ
|
¿ÜºÎ ħÀÔÀ» ¿¹¹æÇÏ°í ¾Ç¼º malware¸¦ Â÷´ÜÇÏ¸é¼ µ¿½Ã¿¡ Çã°¡µÈ »ç¿ëÀÚÀÇ ¾ÈÀüÇÑ Á¢¼ÓÀ» Çã¿ëÇÔÀ¸·Î½á ¸ðµç ŸÀÔÀÇ Æ®·¡ÇÈÀ» ÅëÁ¦ÇÏ´Â ¾ÈÀüÇÑ ÅëÇÕ ³×Æ®¿öÅ© ±¸Ãà. |
Æ÷°ýÀûÀÎ QoS ±â´É:
- Æ÷Æ® ±â¹Ý ȤÀº 802.1p-±â¹Ý ¿ì¼±¼øÀ§ ÁöÁ¤
- Layer 3 ±â¹Ý (DSCP) ¿ì¼±¼øÀ§ ÁöÁ¤
- Æ÷Æ® ±â¹Ý ingress ¹× egress rate limiting
|
ÃÖÀûÈµÈ ³×Æ®¿öÅ© ÆÛÆ÷¸Õ½º ¹× º¸´Ù ³ªÀº º¸À̽º ȤÀº ºñµð¿À¿Í °°Àº Áß¿äÇÑ Æ®·¡ÇÈ Àü¼ÛÀ» À§ÇÑ °í±Þ ÄÁÆ®·Ñ. |
DHCP Snooping |
´ÜÁö ÃøÁ¤ IP/MAC ÁÖ¼Ò¸¦ °¡Áø Ŭ¶óÀ̾ðÆ®¸¸À» ³×Æ®¿öÅ©¿¡ Á¢¼ÓÇϵµ·Ï Çã¶ôÇÔÀ¸·Î½á IP ÁÖ¼Ò ÇÒ´çÀ» È¿À²ÀûÀ¸·Î ÅëÁ¦ °ü¸®ÇÕ´Ï´Ù. |
µà¾ó Æß¿þ¾î À̹ÌÁö ¹× ¼³Á¤ ÆÄÀÏ |
ÃÖ¼ÒÇÑÀÇ ¼ºñ½º ¹æÇظ¸À» °¡Áú ¼ö ÀÖµµ·Ï Æí¸®ÇÑ Æß¿þ¾î ¾÷µ¥ÀÌÆ® ¹× ¼³Á¤ º¯°æÀ» À§ÇÑ µà¾ó Æß¿þ¾î À̹ÌÁö ¹× µà¾ó ¼³Á¤ ÆÄÀÏ. |
Protected Ports |
½ºÀ§Ä¡»ó¿¡ ÀÖ´Â ±× º¸È£µÇ¾îÁø Æ÷Æ®µé »çÀÌ¿¡¼ unicast, broadcast ȤÀº multicast Æ®·¡ÇÈÀÇ ±³È¯ÀÌ ºØÇÊ¿äÇÕ´Ï´Ù. Áï ÇÑÃþ °ÈµÈ ÅëÇÕ ³×Æ®¿öÅ© º¸¾È ȯ°æ¿¡ ÀÇÇØ ±ÍÇÏÀÇ ¹Î°¨ÇÑ ÀüÈ Åëȳ»¿ëÀº »çÀûÀ¸·Î º¸È£µÇ¾îÁö¸ç Áß¿äÇÑ °¨½Ã ½Ã½ºÅÛ ºñµð¿À Ŭ¸³µîÀº ÁöÁ¤µÈ ½ºÅ丮Áö Àåºñ·Î Àü¼ÛµÇ¾î µ¥ÀÌÅÍ ´©¼ö ¹× »ç°í¸¦ ¹Ì¿¬¿¡ ¹æÁöÇØ ÁÝ´Ï´Ù. |
Çϵå¿þ¾î »ìÆ캸±â
¿Ö NETGEAR 10G ½ºÀ§Ä¡°¡ ÇÊ¿äÇÑ°¡?
NETGEAR´Â SMB¸¦ À§ÇÑ ¾÷°è ÃÖÃÊÀÇ ºñ¿ë È¿À²ÀûÀÎ 10G ½ºÀ§Ä¡¸¦ ¼±º¸¿´À¸¸ç °¡Àå È¿À²ÀûÀÎ °¡°Ý¿¡ 10G ¼Ö·ç¼ÇÀ» Á¦°øÇÏ´Â À¯ÀÏÇÑ ³×Æ®¿öÅ© ºê·£µå ÀÔ´Ï´Ù.:
- 10G Áö¿ø °¡´É ¼¹ö ¹× ³×Æ®¿öÅ© ½ºÅ丮Áö¿ÍÀÇ ¿¬°áÀ» ÅëÇØ ÄÚ¾î ½ºÀ§Ä¡·Î¼ È°¿ëÀÌ °¡´ÉÇÕ´Ï´Ù.
- È¿À²ÀûÀÎ ºñ¿ëÀ» °¡Áö°í 10G ¾÷¸µÅ©¸¦ Áö´Ñ ½ºÀ§Ä¡µé°úÀÇ Á¢¼ÓÀ» À§ÇØ Áß°£ ±Ô¸ðÀÇ ³×Æ®¿öÅ©»ó¿¡ ÀÖ´Â ÄÚ¾î ½ºÀ§Ä¡·Î ºÎÅÍ 10G ´ë¿ªÆø È®Àå ½Ã »ç¿ë °¡´ÉÇÕ´Ï´Ù.
- °í±Þ L2 ±â´É, öÀúÇÑ º¸¾È ±â´É, static routing, ´ÙÀ̳ª¹Í VLAN ÁöÁ¤ ¹× IPv6 Áö¿ø µî ´Ù¾çÇÏ°í °·ÂÇÑ °ü¸® ±â´É
- Æò»ý Ç°Áú º¸Áõ ¹× öÀúÇÑ A/S Áö¿ø
±â¼ú »ç¾ç
Physical interfaces
Auto-sensing RJ45 100/1000/10GBase-T
Packet Buffer Memory
- 2 Mb - Dynamically shared across only used ports
Performance Summary
Switching fabric
- 240 Gbps - Line-rate (non blocking fabric)
Green Ethernet
Energy Efficient Ethernet (EEE)
- IEEE 802.3az Energy Efficient Ethernet Task Force compliance- Deactivated by default
Auto-EEE Mode
Power Back Off
- 10GBase-T standard - Drops power consumption by 15% to 20% when short copper cables are detected
Other Matrix
Forwarding mode
Latency (64-byte frames, 10 Gbps, Copper 10GBase-T)
Latency (64-byte frames, 10 Gbps, Fiber SFP+)
Addressing
Address database size
Number of VLANs
- 256 VLANs (802.1Q) simultaneously
Number of multicast groups filtered (IGMP)
Number of Link Aggregation Groups (LAGs - 802.3ad)
- 8 LAGs with up to 8 ports per group
Number of hardware queues for QoS
Number of static routes - IPv4
Number of IP interfaces (port or VLAN)
Jumbo frame support
Acoustic noise (ANSI-S10.12)
- 49.7dBA @ 25 ¡ÆC ambient (77 ¡ÆF)
Heat Dissipation (BTU)
Mean Time Between Failures (MTBF)
L2 Services - VLANs
- IEEE 802.1Q VLAN Tagging
- Protocol based VLANs
- MAC based VLANs
- Voice VLAN - Based on phones OUI bytes (internal database, or usermaintained) or protocols (SIP, H323 and SCCP)
Network Security
- IEEE 802.1x
- Guest VLAN
- RADIUS based VLAN assignment via .1xv
- MAC-based .1x
- Network Storm Protection, DoS
- Broadcast, Unicast, Multicast DoS Protection
- DoS attacks
- DoS Prevention
- Private VLAN
L2 Services - Availability
- IEEE 802.3ad - LAGs
LACP ( (8 LAGS with max. of 8 members in each LAG))
- Broadcast Storm Control
- IEEE 802.3x (Full Duplex and flow control)
- IEEE 802.1D Spanning Tree Protocol
- IEEE 802.1w Rapid Spanning Tree
- IEEE 802.1s Multiple Spanning Tree
- BPDU Guard
L2 Services - Multicast Filtering
- IGMP Snooping (v1, v2 and v3)
- MLD Snooping Support (v1 and v2)
- IGMP Snooping queries
- Block unknown Multicast
L3 Services - DHCP
- DHCP Client
- DHCP Snooping
L3 Services - IPv4 Routing
- Static Routing
- VLAN Routing
- IP Source Guard
- Router Discovery (IRDP)
Network Monitoring and Discovery Services
- 802.1ab LLDP
- SNMP V1, V2, V3
- RMON 1,2,3,9
Network Traffic
- Access Control Lists (ACLs)
L2 / L3 / L4
- IP-based ACLs (IPv4 and IPv6)
- MAC-based ACL
- TCP/UDP-based ACL
- MAC lockdown
- MAC lockdown by the number of MACs
- IEEE 802.1x Radius Port Access Authentication
- Port Security
- DHCP Snooping
Quality of Service (QoS)
- Access Lists
- L2 MAC, L3 IP and L4 Port ACLs
- Ingress rate limiting
- Egress rate limiting
- DiffServ QoS
- IEEE 802.1p COS
- Dst MAC and IP
- IPv4 and v6 DSCP
- IPv4 and v6 TOS
- WRR (Weighted Round Robin)
- Strict Priority queue technology
- Auto-VoIP
Yes, based on protocols (SIP, H323 and SCCP) or on OUI bytes (default database and user-based OUIs) in the phone source MAC address
- Auto Video
- Port Mirroring
IEEE Network Protocols
- IEEE 802.3 Ethernet
- IEEE 802.3z Gigabit Ethernet 1000BASE-SX/LX
- IEEE 802.1D Spanning Tree (STP)
- IEEE 802.3i 10BASE-T
- IEEE 802.3ae 10-Gigabit Ethernet
- IEEE 802.1s Multiple Spanning Tree (MSTP)
- IEEE 802.3u 100BASE-T
- IEEE 802.3ad Trunking (LACP)
- IEEE 802.1w Rapid Spanning Tree (RSTP)
- IEEE 802.3ab 1000BASE-T
- IEEE 802.1AB LLDP with ANSI/TIA-1057 (LLDP-MED)
- IEEE 802.1X Radius network access control
- IEEE 802.1Q VLAN Tagging
- IEEE 802.1p Class of Service
- IEEE 802.3x full-duplex flow control
- IEEE 802.3 af (PoE)
- IEEE 802.3 af (PoE Plus)
Management
- Password management
- Configurable Management VLAN
- Admin access control via Radius and TACACS+
- Web-based graphical user interface (GUI)
- Smart Control Center (SCC) for multiswitch management
- IPv6 management
- Dual Software (firmware) image
- Dual Configuration file
- SNTP client over UDP port 123
- SNMP v1/v2
- SNMP v3 with multiple IP addresses
- RMON 1,2,3,9
- Port Mirroring
- Many to One Port Mirroring
- Cable Test utility
- SSL/HTTPS and TLS v1.0 for web-based access
- File transfers (uploads, downloads) TFTP / HTTP
- HTTP Upload and Download (firmware)
- Syslog (RFC 3164)
LEDs
-
Per port
- Speed, Link, Activity
Per device
Physical Specifications
- Dimensions: 440 x 257 x 44 mm
- Weight: 4.04 kg (8.9 lb)
Power Consumption
- 98.2W (max.) - Worst case, all ports used, line-rate traffic
Environmental Conditions
Operating
Temperature
- 32¡Æ to 122¡ÆF (0¡Æ to 50¡ÆC)
Humidity
- 90% maximum relative humidity, non-condensing
Altitude
- 10,000 ft (3,000 m) maximum
Storage
Temperature
- – 4¡Æ to 158¡ÆF (–20¡Æ to 70¡ÆC)
Humidity
- 95% maximum relative humidity, non-condensing
Altitude
- 10,000 ft (3,000 m) maximum
Electromagnetic Emissions and Immunity
Certifications
- CE mark, commercial
- FCC Part 15 Class A, VCCI Class A
- Class A EN 55022 (CISPR 22) Class A
- C-Tick Class-A
- EN 50082-1
- EN 55024
- KC
Safety
Certifications
- CB mark, commercial
- CSA certified (CSA 22.2 #950)
- UL listed (UL 1950)/cUL IEC 950/EN 60950
- CCC (China Compulsory Certificate)
Warranty and Support
- ProSAFE Lifetime Warranty
- ProSUPPORT 24x7 Advanced Technical Support, 1 year (included)*
ÁÖ¹® Á¤º¸
Package Content All models
- ProSAFE¢ç 12-port 10 Gigabit Ethernet (10GbE) Smart Switch (XS712T)
- Power cord
- Rack-mounting kit
- Resource CD with links to online documentation, installation guides, Webmanagement user manual, Smart Control Center (SCC) software and user guide.
Ordering Information North America and Latin America:
XS712T-100NES Europe, Korea:
XS712T-100NES Asia:
XS712T-100AJS China:
XS712T-100PRS
Optional Modules and Accessories AXM763-10000S
- 10GBase-LRM long reach multimode
AXM762-10000S
- 10GBase-LR long reach single mode, 9/125¥ìm, up to 10km (6.2 miles)
AXM761-10000S
AGM731F-10000S
- 1000Base-SX short range multimode
AGM732F-10000S
- 1000Base-LX SFP GBIC (Single mode)
AXC761-10000S
- 10GSFP+ Cu (passive), SFP+ connectors on both end, 1m (3.3ft)
AXC763-10000S
- 10GSFP+ Cu (passive), SFP+ connectors on both end, 3m (9.8ft)
AXC753-10000S
- 10GSFP+ Cu (passive), one SFP+ connector and one XFP connector, 3m (9.8ft)
|